Operation Manual
Output test
–
Press key “P”.
–
Press key “8”.
–
Press key “Plus”.
–
Select the output element to be tested with the keys “Plus” or
“Minus”.
–
Switch the output on or off with the key “F2”.
–
Press key “Program stop”.
The program is quitted.
Output elements
Switch Designation
Y01 Sewing foot up / down
Y02 Thread tension lift open
Y03 Contour guide up / down
Y04 Stacker off / on
Y05 Ejector roller up / down
Y06 Feeding unit up / down
Y07 Contour guide forward / backward
Y08 Contour guide blowing on
Y09 Move contour guide laterally
Y10 Differential bottom feed on / off
Y11 Needle feed on / off
Y12 Warp separator off / on
Y13 Table blowing off / on
Y14 Dirt suction off / on
Y15 Puller up / down
Y16 Mouse back
35