Operating Manual 512/532 Version 01.0 - 07/2015 79
8.3.7 Fitting the oil collection reservoir
Figure 26: Fitting the oil collection reservoir
1. Insert the retainer (2) into the hole in the table plate (6) and
screw in place using 3 screws (1).
2. Screw the oil collection reservoir (5) into the retainer (2).
3. Pug the oil line (3) into the oil collection reservoir (5).
4. Plug the rubber mounts (4) into the table plate (6).
(1) - Screw
(2) - Retainer
(3) - Oil line
(4) - Rubber mount (in the oil
collection tray)