Operation Manual

7.5 Operator-lev el parameter list for EFKA controls DA82GA and 6F82F A
Parameter Adj. Range Preset
No. Abbr. Name/Function min max 100R
000 Arv starting-bar-tack stitches forward 0 254 2
001 Arr starting-bar-tack stitches backward 0 254 4
002 Err ending-bar-tack stitches backwards 0 254 3
003 Erv ending-bar-tack stitches forwards 0 254 3
004 LS number of light-barrier equalisation 0 254 4
stitches (large stitch length)
005 LSF number of light-barrier filter stitches 0 254 0
for knits
006 LSn number of seams terminated with 0 15 1
the light barrier
007 Stc number of stitches in the 0 254 10
automatically-produced seam section
008 F assigning a function to key 9 1 5 2
1 = softsta r t ON/ OF F
2 = ornamental-stitch bar tack ON/OFF
3 = stroke adjustment
press and release = ON / press and hold = OFF
4 = needle cooling ON/OFF
5 = handwheel reverse ON/OFF **
009 LS light barrier ON/OFF OFF ON OFF
010 cLS number of light-barrier 0 254 8
equalising stitches (small stitch length)
013 FA thread cutter ON/OFF OFF ON ON
014 FW thread retractor ON/OFF OFF ON ON
015 StS s titch c ount ON/OFF OFF ON ON
080 SAv number of stitches, starting 0 254 3
decorative-stitch bar tack forwards
081 SAr number of stitches, starting 0 254 3
decorative-stitch bar tack backwards
082 SEr number of stitches, ending 0 254 3
decorative-stitch bar tack backwards
083 SEv number of stitches, ending 0 254 3
decorative-stitch bar tack forwards
085 cFW residual-thread-monitor stitch count
F-195 = 1-3 0 2540 0
F-195 = 4 0 9990 0
25
GB