9.2 Lubrication
(until July 2003) (from A ugust 2003)
Check the oil level at the sight glass 2 every week.
Top up the oil reservoir only with DA-10 oil or an equivalent oil with
the following specification:
Viscosity at 40° C : 10 mm
2
/s
Ignition point: 150 °C
DA-10 can be obtained from DÜRKOPP ADLER AG sales outlets. The part numbers
are:
250 ml - Container: 9047 000011
1 litre - Container: 9047 000012
2 litre - Container: 9047 000013
5 litre - Container: 9047 000014
Remove oil-filling screw 1 and pour in oil.
Check oil level at sight glass 2.
The oil level must be between “EMPTY” and “FULL”.
Replace oil-filling screw 1.
Clean up any oil overflow.
31
GB
1
2
1