Instruction manual

6 Electrical connection
6.1 General
Caution !
All work on the electrical equipment of this special sewing
machine may only be carried out by qualified electricians or
other appropriately trained persons.
While working on the electrical equipment the mains plug must be
rem ov e d!
6.2 Checking the mains voltage
Caution !
The mains voltage must coincide with the rated voltage specified
on the model-identification plate.
6.3 Connecting the sewing drive
6.3.1 Connecting the clutch motor
Lay the connection cable from the main switch through the cable
duct to the sewing drive and connect it to the sewing drive. See
connection diagram 9800 110002 A/ 9800 110002 D (in the
connection pack) or the circuit diagram on the clutch motor.
Lay the main cable from the main switch through the cable duct to
the back and attach it to the stress-relief.
6.3.2 Connecting the direct-current positioning actuator
Lay the connection cable from the main switch through the cable
duct to the sewing drive and connect it to the sewing drive. See
connection diagram 9800 130014 R (in the connection pack).
Lay the main cable from the main switch through the cable duct to
the back and attach it to the stress-relief.
Plug the cable from the set-point generator into socket b80 of the
drive control. See sketch on page 29.
22