6.7 Connecting the sewing light transformer (optional equipment)
Remove the machine’s mains plug.
Pass the mains cable 1 of the sewing-lamp transformer through
the cable duct 2 to the main switch.
It is connected to the mains-connection side of the main switch (or
motor-protection s witch). See connection diagram 9800 120009 A
or 9800 110002 A or 9800 130014 R.
Stick the adhesive label with the safety instruction on the front of
the main switch .
If the sewing-lamp transformer is connected to a 3 x 380 - 415V
three-phase supply it must have a neutral conductor.
Caution !
The sewing-light transformer is directly connected to the mains.
It is therefore live even when the main switch is switched off.
The mains plug must be removed before carrying out any work
on the sewing-light transformer, e.g. changing the fuse.
25
21