Manual

Duro-Last, “World’s Best Roof”, Duro-Bond and Duro-Guard are registered marks owned by Duro-Last, Inc.
Updated: 11/19/2013
2 of 2 www.duro-last.com 800-248-0280
DURO-LAST
®
40 MIL MEMBRANE
Codes and Standards:
Underwriters Laboratories (US & Canada), FM Approvals, ICC-ES (ESR-1660), State of Florida, Miami-Dade
County, Texas Department of Insurance.
Storage:
Store rolls on their sides and on pallets. Use tarps to keep rolls dry.
Membrane Attachment:
Mechanically Fastened – DL40 membrane may be mechanically attached to a variety of roof deck and wall
materials. An appropriate slip sheet or cover board may be required. Refer to the Duro-Last Mechanically
Fastened Systems Specification for system requirements.
Duro-Bond
®
System – The Duro-Bond system (inductive weld) may be used to attach DL40 membrane. Refer
to the Duro-Last Duro-Bond System Specification for system requirements.
Adhered – DL40 membrane may be adhered to a variety of properly prepared roof decks, walls, cover boards
and insulations including Duro-Guard™ ISO products, DensDeck
®
Prime Roof Board and SECUROCK
®
Gypsum-Fiber Roof Board. Refer to the Duro-Last Adhered Systems Specification for system requirements.
Physical Properties:
DL40 membrane has been subjected to the tests required by ASTM 4434 “Standard Specification for Poly (Vinyl
Chloride) Sheet Roofing” and has been classified as a Type IV, internally reinforced sheet. The results of each
test are listed below.
Physical Property Test Method ASTM 4434 Requirement Result Typical Value
Overall Thickness ASTM D751
0.036 in.
PASS 40 mil, nominal
Breaking Strength
1
ASTM D751 Grab Method
275 lbf./in.
PASS 355 lbf x 441 lbf
1
Elongation
1
ASTM D751 Grab Method
25%
PASS 28% x 31%
1
Seam Strength ASTM D 751 Grab Method
330 lbf
(75% of Breaking Strength)
PASS 360 lbf
Tear Strength
1
ASTM D751 Procedure B
90 lbf.
PASS 125 lbf x 136 lbf
1
Low Temp. Bend ASTM D2136
Must Pass at – 40 °F
PASS PASS
Heat Aging ASTM D3045
Conditioned for 56 days in oven
maintained at 176 °F
PASS PASS
Accelerated Aging
ASTM G154
(formerly G53)
5,000 hour total test time.
Irradiance level of 0.68 W/m2-nm.
Cycle: 8 hour at 145 °F,
4 hour condensation at 122 °F
PASS PASS
Dimensional Stability
1
ASTM D1204
Conditioned for 6 hours in oven
maintained at 176 °F.
Allowable change: 0.5%
PASS -0.45% x -0.40%
1
Water Absorption ASTM D570
Immersed in water at 158 °F
for 168 hours.
Allowable Weight Change: 3%
PASS 2.6%
Static Puncture ASTM D5602
33 lbf
PASS 56 lbf
Dynamic Puncture ASTM 5635
14.7 ft-lbf (20 J)
PASS
14.7 ft-lbf (20 J)
1
Typical values are shown for both machine and cross machine directions. The machine direction results are listed first.
Additional Tests
Fungi Resistance ASTM G-21 No Sustained growth or discoloration
Moisture Vapor Transmission ASTM E96, Proc. B, Method A < 0.22 U.S. Perms