Tool Service Customer customer_service@maxtool.com or call 1-800-629-3325 (option 3) Monday - Friday 7am to 5pm. PST Product Support (Product: information, application, and service info & warranty questions) support@maxtool.com or call 1-800-629-3325 (option 4) Monday - Friday 7am to 5pm. PST This manual provides information regarding the operation and maintenance of these products. We have made every effort to ensure the accuracy of the information in this manual.
The generator is a potential source of electrical shock if misused. Do not expose the generator to moisture, rain or snow. Do not let the generator get wet, and do not operate it with wet hands. These labels warn you of potential hazards that can cause serious injury. Read them carefully.
SAFETY INFORMATION Read and understand this instruction manual before operating your generator. You can help prevent accidents by being familiar with your generator’s controls, and by observing safe operating procedures. Operator Responsibility Know how to stop the generator quickly in case of emergency. Understand the use of all generator controls, output receptacles, and connections. Do not let children operate the generator without parental supervision.
CONTENTS SAFETY INFORMATION……………………………………………………………..2 COMPONENT IDENTIFICATION…………..…………………………………….…4 WATTAGE REFERENCE CHART……..……………………………………… . ... ..7 SPECIFICATIONS…………………………………………….………………….……8 WIRING DIAGRAM………………………………………………………….……..…9 ASSEMBLY………………………………………………………..……………….……10 PRE-OPERATION CHECK……………………………………………………...…….10 STARTING THE ENGINE/STOPPING THE ENGINE………………..…….………12 OPERATING INSTRUCTIONS………………………………………….…….…….. .12 MAINTENANCE…………………………………………..…………………….………15 STORAGE………………………………………………….
4
Engine Key To start and stop the engine. Key position: OFF: To stop the engine. Key can be removed / inserted. ON: To run the engine after starting, or to pull start the unit. START: To start the engine by operating the starter motor. Do not turn the key switch to START position when the engine is running to prevent damage to the starting motor. Recoil Starter To start the engine, turn the key to on, pull the starter grip lightly until resistance is felt, then pull briskly.
Change the Voltage Selector Switch after turning the AC circuit breaker to OFF. The generator may be damaged if the Voltage Selector Switch is changed with the breaker in the ON position. Ground Terminal The generator ground terminal is connected to the frame of the generator, the metal non-current-carrying parts of the generator, and the ground terminals of each receptacle. DC Receptacle The DC receptacle may ONLY be used for charging 12 volt automotive type batteries.
WATTAGE REFERENCE CHART Electric equipment, especially engines produce strong current when being started. The table below offers references when you connect those installations to generator. Tool or Appliance Rated* (Running) Watts Additional Surge (Starting) Watts Light Bulb-75 watt 75 - Deep Freezer 500 800 Sump Pump 800 1200 Refrigerator/Freezer-18 Cu. Ft.
SPECIFICATIONS Generator Engine Standard Features Dimensions Model XP12000EH Frequency 60 HZ Max. AC Output 12000 Watt Rated AC Output 9500 Watt Run Time 8 hour Model XP18HPE Type Air Cooled, OHV, 4-Stroke Displacement 457 cc Output 9.5kw / 3600 rpm Fuel Unleaded Gasoline Fuel Tank Capacity 8.3 Gallon Decibel <72 dBA Oil Alert Standard Battery 12V 18A/hr.
ASSEMBLY Wheel Kit Installation 1 Install the axle assembly on the generator. 2 Install the two wheels on the axle shaft using the flange nuts. 3 Install the two stands on the under frame using the flange nuts. Starter Cables Connection 1 Route the starter cable under the tank. 2 Connect the starter cable to the battery positive (+) terminal first, then to the negative (-) terminal. When disconnecting, disconnect at the battery negative (-) terminal first.
SAE 10W-30 is recommended for general, all-temperature use. Other viscosities shown in the chart may be used when the average temperature in your area is within the indicated range. 1 Remove the oil filler cap and wipe the dipstick clean. 2 Check the oil level by inserting the dipstick into the filler neck without screwing it in. 3 If the level is low, fill to the top of the oil filler neck with the recommended oil. Fuel Check the fuel gauge, and refill the tank if the fuel level is low.
Starting the Generator: Gasoline CAUTION: LPG must be shut off when using gasoline! Gasoline must be shut off when using LPG! Disconnect all electrical loads from the generator before attempting to start! 1. Make sure that the AC circuit breaker is in the OFF position. The generator may be hard to start if a load is connected. 2. Turn the fuel valve lever to the ON position. 3. The choke will need to be closed, slide the choke lever out to the CLOSED position.
Starting the Generator: Propane CAUTION: LPG must be shut off when using gasoline! Gasoline must be shut off when using LPG! Disconnect all electrical loads from the generator before attempting to start! 1. Make sure that the AC circuit breaker is in the OFF position. The generator may be hard to start if a load is connected. 2. Turn the gasoline fuel valve to the "OFF" position. 3. Connect the propane gas hose to the regulator/decompression valve. 4.
Starting the Generator: Propane (Continued) WARNING: WHEN USING THE GENERATOR WITH LPG MAKE SURE THERE IS NO POSSIBLE IGNITION SOURCE CLOSE TO THE GENERATOR. 1. Before using, make sure all of the LPG connectors and hoses are well connected and sealed. 2. Connect electrical devices to generator ONLY after the engine runs smoothly. (There may be remnant gasoline in the carburetor; this can cause unsteady engine performance for several minutes) 3.
potential for electrical shock. If an appliance begins to operate abnormally, becomes sluggish or stops suddenly, turn it off immediately. Disconnect the appliance, and determine whether the problem is the appliance, or if the rated load capacity of the generator has been exceeded. Make sure that the electrical rating of the tool or appliance does not exceed that of the generator. Never exceed the maximum power rating of the generator.
DC Operation The DC terminals may ONLY be used for charging 12 volt automotive type batteries. Connecting the battery cables: 1 Before connecting the battery charging cables to a battery that is installed in a vehicle, disconnect the vehicle ground battery cable from the battery negative (-) terminal. Batteries give off explosive gases; keep sparks, flames and cigarettes away. Provide adequate ventilation when charging or using batteries.
5 Reconnect the vehicle ground battery cable to the battery negative (-) terminal. High Altitude Operation At high altitude, the standard carburetor air/fuel mixture will be too rich. Performance will decrease, and fuel consumption will increase. A very rich mixture will also foul the spark plug and cause hard starting. Operation at an altitude that differs from that at which this engine was certified, for extended periods of time, may increase emissions.
First Every3 Every6 REGULAR SERVICE PERIOD(2) Before each month months months ITEM use or 20 or 50 or 100 Performed at every indicated month or Hrs. Hrs. Hrs. operating hour interval, whichever comes first. Check ○ ● Engine oil Change ○ ○ Check ○ ● Air cleaner Clean ○ (1) Sediment cup Clean ● ○ Clean-Adjust ○ ● Spark plug Replace Clean ● Spark arrester ○ Idle speed Check-Adjust ● Check-Adjust ● Valve clearance ● Combustion Clean After every 500 Hrs.
Never run the generator without the air filter. Rapid engine wear will result. 1 Unsnap the air cleaner cover clips, remove the air cleaner cover, and remove the element. 2 Wash the air cleaner element in a solution of household detergent and warm water, then rinse thoroughly, or wash in nonflammable or high flashpoint solvent. Allow the air cleaner element to dry thoroughly. 3 Soak the air cleaner element in clean engine oil and squeeze out the excess oil.
The gap should be: 0.028 0.031 in (0.70 0.80 mm) 6 Check that the spark plug washer is in good condition, and thread the spark plug in by hand to prevent cross-threading. 7 After the spark plug is seated, tighten with a spark plug wrench to compress the washer. -If installing a new spark plug, tighten 1/2 turn after the spark plug seats to compress the washer. If reinstalling a used spark plug, tighten 1/8 -1/4 turn after the spark plug seats to compress the washer.
TROUBLESHOOTING Note: Troubleshooting problems may have similar causes and solutions. PROBLEM The engine will not start No electricity at the AC receptacles POSSIBLE CAUSE SOLUTION Is there fuel in the tank? Refill the fuel tank. Is there enough oil in the engine? Add the recommended oil. Is the spark plug in good condition? Readjust gap and dry the spark plug. Replace it if necessary. Is the fuel reaching the carburetor? Clean the fuel sediment cup.
GENERATOR ASSEMBLY AND MOUNTING The Generator is supplied with a wheel kit. If you want to install the wheel kit on your unit, please follow the instructions below. If you not use the wheel kit, please skip this section. 1. Place the bottom of the generator on a flat, even surface. You may temporarily place the generator on blocks to ease assembly. 2. Attach the support leg to the cradle with bolts (M8x 16) and tighten nuts (M8) (see figure 1 ). 3.
CHANGE THE CARBON-BRUSH CHANGE THE AVR 22
Maintenance Log MODEL: XP12000EH Date Generator Hrs.
Product Support Product Information, Application, Service Info & Warranty Questions Please email us at support@duromaxgenerators.com or call (800) 629-3325 Monday - Friday 7am to 5pm.