Operating Guide

Turn breaker on / connect
The breaker is located on the right side of the front power
panel. Flip the breaker up to allow power to ow to the
receptacles. Connect your devices to the receptacles on the
front panel. Start with the largest loads rst.
8.
29
Release propane pressure
The propane regulator / decompression valve is located on
the frame of the generator below the OHV valve cover. Press
the button in the center down 3-5 times for one second to
clear the air from the lines and ll the carburetor.
5.
Adjust choke
The choke lever is located above the air lter to the right of
the recoil start. Slide the lever to the right to open the choke
and increase air into the carburetor for normal running.
6.
7.
Start
The key switch is located on the left side of the front power
panel. Insert the key and turn to the start position to start
the generator. Allow the key to return to the on position
once started.