Operating Guide

MAINTENANCE AND CARE
Proper routine maintenance of your generator is essential for safe, economical, and trouble-free
operation. It will also help reduce air pollution.
Maintenance Schedule
Remember that this schedule is based on the assumption that your machine will be used for its
designed purpose. Sustained high-load, high temperature operation, or use in unusually wet or
dusty conditions, will require more frequent service.
WARNING: Improper maintenance, or failure to correct a problem before operation, can
cause a malfunction in which you can be seriously injured or killed. Always follow the
inspection and maintenance recommendations and schedules in this instruction manual.
Make sure the engine is o before you begin any maintenance or repairs.
Let the engine and exhaust system cool before touching.
To reduce the possibility of re or explosion, be careful when working around
gasoline. Use only a nonammable solvent, not gasoline, to clean parts. Keep
cigarettes, sparks, and ames away from all fuel related parts.
SERVICE
REGULAR SERVICE PERIOD
BEFORE
EACH USE
EVERY MO. OR
20 HRS
EVERY 3 MO. OR
50 HRS
EVERY 6 MO. OR
100 HRS
EVERY 12 MO.
OR 300 HRS
ENGINE OIL CHECK
CHANGE
AIR CLEANER CHECK
CHANGE
SEDIMENT CUP CLEAN
SPARK PLUG CLEAN-
ADJUST
REPLACE
SPARK ARRESTOR CLEAN
IDLE SPEED CHECK /
ADJUST
VALVE CLEARANCE CHECK-
ADJUST
COMBUSTION
CHAMBER
CLEAN
500 HOURS
FUEL TANK / FILTER CLEAN
FUEL TUBE CHECK EVERY 24 MO. (REPLACE IF NECESSARY)
TO BE PERFORMED AT EVERY MONTH INDICATED OR HOUR INTERVAL WHICH EVER COMES FIRST
40