Owner`s manual
12
United Air Specialists, Inc.
Supra-Pulse FJH Series
Cartridge Dust Collector
Revised 02/02
MAGNEHELIC
®
GAGE INSTALLATION
If your system was ordered with a Magnehelic Gage,
remove it and the hardware from the box. Instructions
for mounting and connecting the Magnehelic Gage are
provided from the manufacturer. Follow these instructions
using the hardware provided. It should be installed
within sight of the Supra-Pulse as shown in Figure 2.
NOTE: The hardware provided is designed for surface
mounting of the Magnehelic Gage. Be certain
to install the 1/8" NPT pipe plugs in the
pressure ports on the back of the gauge.
Install the tube fittings in the pressure ports on the side
of the gauge. Mount it to the bracket and the bracket to
a support structure.
PHOTOHELIC
®
GAGE INSTALLATION
If your system was ordered with a Photohelic Gage,
remove it and the hardware from the box. Instructions
for mounting and connecting the Photohelic Gage are
provided from the manufacturer. Follow these
instructions using the hardware and UAS mounting
bracket provided. The Photohelic Gage and mounting
bracket should be installed within sight of the Supra-
Pulse as shown in Figure 2. Hardware to mount the
bracket to the support structure is not supplied by UAS.
NOTE: Be certain to install the two jumper wires (not
supplied by UAS) as shown in the instruction
manual provided with the gauge. Also see
Figure 11.
SUPRA-CLEAN TIMERBOARD INSTALLATION
Your system comes standard with a Supra-Clean timer
control for sequence pulse cleaning of your cartridge
filters. The timer should be installed within sight of the
Supra-Pulse as shown in Figure 2. Hardware to mount
the panel to the support structure is not supplied by UAS.
SUPRA-VIEW PANEL INSTALLATION
If your system was ordered with a Supra-View control
panel, remove panel and hardware from the box. The
panel should be installed within sight of the Supra-Pulse
as shown in Figure 2. Hardware to mount the panel to the
support structure is not supplied by UAS. Refer to the
Supra-View Owner’s Manual
for proper installation details.
SUPRA-I.Q. DIAGNOSTICS PANEL
INSTALLATION
If your system was ordered with a Supra-I.Q.
diagnostics panel, please refer to the
Supra-I.Q.
Owner’s Manual
for proper installation details.
FINAL CONNECTIONS FOR ALL GAUGE
OPTIONS
For any control system, connect the black, plastic
pressure tubing (25 feet provided by UAS) to the gauge
or panel fittings and the Supra-Pulse. Connect the dirty
air plenum on the Supra-Pulse to the high pressure port
on the gauge or panel and the clean air plenum on the
Supra-Pulse to the low pressure port on the gauge or
panel as shown in Figure 10. Zero, calibrate and maintain
the gauge as recommended by the manufacturer on the
instructions provided with the gauge.
4.5 COMPRESSED AIR CONNECTION
Clean, dry, 90-110 PSIG compressed air is required for
the pulse cleaning system to properly function. Com-
pressed air consumption is noted on the unit sales draw-
ing. A shut-off valve, pressure regulator and pressure
gauge should be installed close to the Supra-Pulse unit.
UAS recommends dedicated oil and water removal filters
be used to ensure clean, dry air is delivered to the pulse
system. Contact your local DUST-HOG representative for
information on the UAS pneumatic valve kit. See Figure 9
for recommended compressed air piping.
NOTE: A 1" diameter or larger compressed air supply
pipe is required.
Provide 1" minimum compressed air line piping to the
unit. The pipe diameter should be based on the main
line pressure, length of pipe run and number of pipe
bends from the main line to the unit. The pipe
connection for the Supra-Pulse unit is located on the
bottom of the air reservoir manifold(s) on the back of the
module(s) as shown in Figure 2. The connection size is
a female 1" NPT fitting.
NOTE: Purge the compressed air line to remove any
debris prior to making the final connection to
the Supra-Pulse compressed air mainifold(s).
Remove the plastic plug from the Supra-Pulse air
manifold(s) prior to making the final compressed air pipe
connection. Apply pipe sealant to ensure a leak-free
connection.
!
CAUTION
Do NOT allow water and/or oil from the compressed
air system into the compressed air manifold on the
Supra-Pulse. To ensure a water-free air supply,
especially when the unit is installed outdoors, a water
filter with automatic drain or a condensate trap with
automatic drain must be installed just before the piping
enters the Supra-Pulse (see Figure 9).