Troubleshooting guide
If a drum lid latch kit was ordered, attach the separate
clamp band around the 55-gallon (208 liter) drum or
30-gallon (114 liter) short drum, leaving the cinch bolt
loose. Position the three latch pawls onto the drum lid
catches, rotating the drum lid as required. Tighten the
cinch bolt and adjust the latch tension or band
placement as required (refer to Figure 17).
If a slide gate was ordered, it was factory installed on
the hopper. Open the slide gate. Repeat for multiple
drum lid connections.
NOTE: The hopper(s) is not designed for dust storage.
The slide gate should remain open during
normal operation.
INLET COLLAR AND BLANK COVER PLATE
INSTALLATION
Inlet collar and blank cover plates bolt directly to the
Supra-Blast unit. Inlet and outlet collar assemblies are
specified with initial order. If inlet diameters or locations
are not specified with initial order, the dust collector is
supplied with all blank cover plates.
MAGNEHELIC
®
GUAGE INSTALLATION
If your system was ordered with a Magnehelic Guage,
remove it and the hardware from the box. Instructions
for mounting and connecting the Magnehelic Guage are
provided by the manufacturer. Follow these instructions
using the hardware provided. The gauge should be
installed within sight of the Supra-Blast unit as shown in
Figure 18.
NOTE: The hardware provided is designed for surface
mounting of the Magnehelic Guage. Make
certain to install the 1/8" NPT pipe plugs in the
pressure ports on the back of the gauge.
Install the tube fittings in the pressure ports on the side
of the gauge. Mount it to the bracket, and the bracket to
a support structure.
PHOTOHELIC
®
GUAGE INSTALLATION
If your system was ordered with a Photohelic Guage,
remove it and the hardware from the box. Instructions
for mounting and connecting the Photohelic Guage are
provided by the manufacturer. Follow these instructions
using the hardware and UAS mounting bracket provided.
The Photohelic Guage and mounting bracket should be
installed within sight of the Supra-Blast as shown in
Figure 18. Hardware to mount the bracket to the support
structure is not supplied by UAS.
The Photohelic Guage requires electrical connections.
Refer to Figure 11 for details.
NOTE: Make certain to install the two jumper wires
(customer-supplied) as shown in the instruction
manual provided with the gauge.
Refer to the manufacturer’s instructions for outdoor
installation.
FINAL CONNECTIONS FOR ALL
GAUGE OPTIONS
For any control system, connect the black, plastic
pressure tubing (25 feet [7.5 meters] provide by UAS)
to the gauge or panel fittings and the Supra-Blast unit.
Connect the dirty air plenum of the Supra-Blast to the
high pressure port on the gauge or panel as shown in
Figure 18. Connect the clean air plenum of the Supra-
Blast to the low pressure port on the gauge or panel as
shown in Figure 18. Zero, calibrate and maintain the
gauge as recommended by the manufacturer.
NOTE: Gauge should be installed within 50 feet
(15 meters) of the dust collector.
SUPRA-CLEAN TIMERBOARD INSTALLATION
Please refer to the Supra-Clean
Installation and
Operation Manual
for proper installation details.
SUPRA-VIEW PANEL INSTALLATION
Please refer to the Supra-View
Installation and
Operation Manual
for proper installation details.
SUPRA-I.Q. DIAGNOSTICS PANEL
INSTALLATION
If your system was ordered with a Supra-I.Q. Diagnostics
Panel, please refer to the Supra-I.Q.
Installation and
Operation Manual
for proper installation details.
REMOTE BLOWER START/STOP ASSEMBLY
A remote blower start/stop pushbutton station is available
for field installation on Supra-Blast assemblies that have
been configured with a combination magnetic motor/
blower starter control package supplied by UAS. The
combination magnetic motor/blower starter control
package must be configured and wired in accordance
with Figure 11, 12 or 13. The customer is required to
!
WARNING
Failure to install 1/8" NPT pipe plugs in pressure ports
on the rear of the Magnehelic Guage will cause the
gauge to read incorrectly.
25
United Air Specialists, Inc.
Supra-Blast
Cartridge Dust Collector
Revised 02/02