Troubleshooting guide
gate, close the slide gate before servicing the dust
storage drum(s). The dust collector fan and compressed
air cleaning systems do not have to be turned off if the
hopper slide gate is closed prior to servicing storage
drums. Remember to open the slide gate when the dust
storage drum is replaced.
6.4 SERVICING THE COMPRESSED AIR
COMPONENTS
1. The compressed air system should be periodically
checked to ensure clean, dry, oil-free air is
delivered to the Supra-Blast dust collector. Check
the compressed air components and service as
recommended by the manufacturer.
2. Periodically check the dust collector air manifold
reservoir(s) for contaminants and drain any
condensed liquid from manifold reservoirs. It is
recommended that the customer install an automatic
air line drain valve at the lowest section of the
compressed air line piping to the dust collector
(refer to Figure 15).
3. With the compressed air supply turned on, check the
diaphragm valves, electronic solenoid valves and
interconnecting tubing between both devices for any
air leakage. Replace any components that are
defective or worn.
Supra-Max Series UAS Part Number General Description of Filter Media
Supra-Netmax 33-10001-0001 80/20 mixture of cellulose/polyester
Supra-Netmax-FR 33-10001-0002 80/20 mixture of cellulose/polyester with fire retardant
material treatment
Supra-Fibrousmax 33-10001-0003 Half the media quantity of the Supra-Netmax
Supra-Fibrousmax-FR 33-10001-0004 Half the media quantity of the Supra-Netmax-FR
Supra-Fibrousmax-W 33-10001-0005 Mixture of polyester and fiberglass fibers
Supra-Releasemax-P 33-10001-0007 Spun–bond polyester fibers
Supra-Releasemax-T 33-10001-0008 Spun–bond polyester fibers with PTFE surface membrane
Table 2 — Supra-Max Series Cartridge Filters
32
United Air Specialists, Inc.
Supra-Blast
Cartridge Dust Collector
Revised 02/02
6.5 SERVICING THE DIRECT DRIVE
BLOWER AND MOTOR SYSTEM
Periodically inspect fan blades to ensure proper fan life.
Clean the fan blades of any deposited material. Grease
motor(s) every 3,600 hours with high grade ball and
bearing grease. Recommended greases are Shell
Dolium or Chevron SRI-2.
Refer to blower assembly
Installation and Operation
Manual
provided with blower assembly for additional
servicing requirements.
6.6 SERVICING OPTIONAL RETURN AIR
SAFETY FILTERS (HEPA/ASHRAE)
Periodically check the pressure drop across the return
air safety filters. Replace when the differential pressure
drop exceeds 2" w.g. (51 mmAq) for ASHRAE filters and
3" w.g. (76 mmAq) for HEPA filters.
6.7 SUPRA-MAX SERIES CARTRIDGE FILTERS
The Supra-Blast product line is designed to accept
Supra-Max Series cartridge filters. Table 2 highlights the
most common Supra-Max cartridge filters.
United Air Specialists will custom design Supra-Max
cartridge filters for application-specific systems. Contact
the nearest United Air Specialists office listed on the back
cover of this manual for additional information.
Magnehelic
®
and Photohelic
®
are registered trademarks of Dwyer
Instruments, Inc.
!
CAUTION
Shut off and slowly release the pressure in the
compressed air piping or the Supra-Blast compressed
air manifold reservoir prior to servicing this equipment.
!
CAUTION
All electrical work should be performed by a qualified
electrician in accordance with local electrical codes.
Disconnect electrical power before installing or