User's Manual

ETERNA2 Regulatory User Guide Dust Networks 15
FCC Testing
ETERNA2 complies with Part 15.247 modular (Intentional Radiator) of the FCC rules and regulations. In order to fulfill FCC
certification requirements, products incorporating ETERNA2 must comply with the following:
5. An external label must be provided on the outside of the final product enclosure specifying the FCC identifier as
described in 6.3.2 below.
6. The antenna must have lower gain than specified in 6.3.1.
7. The device integrating ETERNA2 may not cause harmful interference and must accept any interference received,
including interference that may cause undesired operation.
8. An unintentional radiator scan must be performed on the device integrating ETERNA2, per FCC rules and
regulations, CFR Title 47, Part 15, Subpart B. See FCC rules for specifics on requirements for declaration of
conformity.
6.3.1 Antenna Selection
Per KDB Publication No. 558074, ETERNA2 may be mated with an antenna with a maximum gain of 6.6 dBi.
6.3.2 OEM Labeling Requirements
The Original Equipment Manufacturer (OEM) must ensure that FCC labeling requirements are met. The outside of the final
product enclosure must have a label with the following (or similar) text specifying the FCC identifier. The FCC ID and
certification code must be in Latin letters and Arabic numbers and visible without magnification.
Contains transmitter module FCC ID: SJC-ETERNA2
Or
Contains FCC ID: SJC-ETERNA2
6.4 Industry Canada (IC) Compliance / Conformité à la norme
Industrie Canada (IC)
Under Industry Canada regulations, this radio transmitter may only operate using an antenna with a maximum (or lesser) gain
approved for the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna gain
should be so chosen that the equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful
communication.
Suivant la législation Industrie Canada, ce transmetteur radio ne peut être utilisé qu’avec une antenne dont le gain est
inferieur au gain approuvé pour le transmetteur par Industrie Canada. Pour réduire le risque d’interférence aux autres
utilisateurs, l’antenne doivent être choisies telle que la puissance isotrope rayonnée équivalente (PIRE) ne dépasse pas ce qui
est nécessaire pour une communication réussie.
6.4.1 RF Exposure / Exposition aux Rayonnements Radiofréquences
The radiated output power of ETERNA2 is far below the IC radio frequency exposure limits. ETERNA2 complies with IC
radiation exposure limits set forth for an uncontrolled environment. When nearby persons has to be kept to ensure RF
exposure compliance, in order to comply with RF exposure limits established in the ANSI C95.1 standards, the distance
between the antennas and the user should not be less than 20 cm (8 inches). ETERNA2 shall not be co-located with any
other tranmsitter within 20 cm; otherwise further transmitter testing may be required.
La puissance émise par ETERNA2 est largement inferieure aux limites d’exposition aux rayonnements de la norme IC.
ETERNA2 est conforme aux limites d’exposition aux rayonnements de la norme IC établies pour un environnement non
contrôlé. Pour garantir la conformité aux limites d’exposition aux rayonnements de la norme ANSI C95.1, la distance entre
l’antenne et toute personne doit être supérieure à 20 cm (8 pouces). ETERNA2 ne doit pas être localisé à proximité d’un
autre transmetteur à moins de 20 cm ; le cas échéant, d’autres mesures de rayonnement pourraient être nécessaires.