User's Manual

Hangzhou Roombanker Technology Co., Ltd. A DUSUN company
Hangzhou Roombanker Technology Co., Ltd. Floor 8, building A, Wantong center,
Tel:86-571-86769027/8 8810480 Hangzhou 310004, china
Website: www.dusuniot.com www.dusunremotes.com www.dusunlock.com
2.2 Outline size
3 Key components
Some key components are shown in the table below
No.
Part No.
Spec
Manufacturer
Remark
1
MCU
APM32F030ZET6
Geehy
2
Zigbee module
DSM-041
Dusun
3
485 IC
TP485E
3PEAK
4 Basic function
4.1 LED blinking and key description
Status Indicator:
Fast flashing: 2Hz,Duty50%;slow flashing: 1Hz,Duty50%.
Indicator
Status
Description
Blue
Off
Device is not powered on
Slow flashing once in 5 seconds
Device is working normally
green
Slow flashing 3 times
Restore factory
Slow flashing
Pair mode
Red
Slow flashing
Low voltage
Fast flashing
Shut down
Always on
Network failure
Note: When the indicator and status lights are working, the power indicator does not work.
Short press: key time <200mS
4.2 Power-on initialization
When the product is powered on, the Blue indicator flashes slowly for 2 times and then stays on, and the
initialization is successful.
4.3 Pairing
After the product is initialized, short press the pairing button once, the device enters the pairing mode, the
distribution Green LED indicator flashes quickly, and exits the distribution network status directly after the timeout,
the timeout period is 60S.
4.4 Restore factory settings
Press the key for more than 30S, the distribution Green LED flashes 3 times, the device restores the factory