Owner’s Manual Electric Storage Water Heaters Standard Models: 0F118G, 80F124G, 80F136G 8 125S118, 125S136, 160S124, 160S136 250S136, 315S136, 315S236, 315S248 400S136, 400S236 An ‘H’ at the end of the model number indicates that the water heater is fitted with a hard-water anode.
Owner’s Manual – Proflo Electric Storage Water Heaters Contents Installation Details 1 Plumbing Connections 3 Electrical Connection 5 Specifications 6 Operating Instructions 7 Safety Information 8 Service Information 9 Troubleshooting 10 Warranty 12 © Dux Manufacturing Limited 2012. All rights reserved. H0421 0421 Rev.
Owner’s Manual – Proflo Electric Storage Water Heaters Installation Details Installation Requirements This water heater must be installed by a licensed tradesperson, and in accordance with: • AS/NZS 3500.4 Plumbing and Drainage – Heated Water Services. • AS/NZS 3000. • Local authority regulations. • Outside Australia, please refer to local plumbing and building codes and regulations.
Owner’s Manual – Proflo Electric Storage Water Heaters Installation Details Location The water heater should be located as close as possible to the most frequently used hot water outlet. Adequate access must be made for service to the element(s), thermostat, relief valve and anode. Ensure that the data plate and associated warnings are clearly visible. Note: All models are equipped with a sacrificial anode, accessible through the top cover.
Owner’s Manual – Proflo Electric Storage Water Heaters Plumbing Connections Pressure & Temperature Relief Valve The Pressure & Temperature Relief Valve is supplied loose with the water heater. The valve rating is: 80, 125 and 160 litre models: - 1,400 kPa 250, 315 and 400 litre models: - 1,000 kPa The PTR valve must be installed directly into the top socket marked “RELIEF VALVE”.
Owner’s Manual – Proflo Electric Storage Water Heaters Plumbing Connections Hot Water Connection The hot water pipe should be connected to either of the RP¾/20 sockets marked "OUTLET" at the top of the unit. For the most economical operation of the water heater, it is recommended that all hot water lines are insulated. Hot water pipes installed outdoors should be insulated with UV stabilised insulation.
Owner’s Manual – Proflo Electric Storage Water Heaters Electrical Connection This water heater is designed for single phase 240V A.C. supply only. The electrical connection must comply with Local Supply Authority Regulations and AS/NZS 3000. Danger: The operation of the thermal cut-out indicates a possibly dangerous situation. Do NOT reset the thermal cutout until the water heater has been serviced by a qualified person.
Owner’s Manual – Proflo Electric Storage Water Heaters Specifications B A C D E Nominal Dimensions Tank Size Total Height (A) Total Diameter (B) Outlet Height (C) Inlet Height (D) Electrical Entry (E) 80L 925 490 735 160 85 125L 1090 530 865 190 100 160L 1345 530 1120 190 100 250L 1445 620 1210 195 105 315L 1765 620 1530 195 105 400L 1705 705 1445 220 130 Specifications 315L 400L 321 321 415 415 315 315 400 400 – 40 – 70 80L 125L 160L 250L 315L Storage Capacity (L) 88 130
Owner’s Manual – Proflo Electric Storage Water Heaters Operating Instructions Safety This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children and animals should be supervised to ensure that they do not interfere with the appliance.
Owner’s Manual – Proflo Electric Storage Water Heaters Safety Information Warning For safe performance, this water heater is fitted with: 1. Combination Thermostat and overtemperature energy cut-out. 2. Combination Pressure & Temperature Relief Valve. These devices must not be tampered with or removed. The water heater must not be operated unless each of these devices is fitted and in working order. Any electrical covers should be removed only by a licensed tradesperson.
Owner’s Manual – Proflo Electric Storage Water Heaters Service Information Six Monthly Service (By Owner) Operate the Pressure & Temperature Relief Valve for approximately 10 seconds by operating the easing lever on the valve to ensure water is relieved to waste through the relief drain pipe. Check to ensure the valve closes correctly. iv. Disconnect the cold water inlet union to the heater and attach a drain hose.
Owner’s Manual – Proflo Electric Storage Water Heaters Troubleshooting What Should I Check Before Making A Service Call? If there is not enough hot water, it is recommended that the following points be considered before making a service call. If after checking the following points the problem has not been identified, please contact Dux on 1300 365 115. are using 450 litres of water it is possible that there will be certain times of the day where there is insufficient hot water.
Owner’s Manual – Proflo Electric Storage Water Heaters Troubleshooting Steady Flow (PTR) – More than 20L per day This may be caused by excessive water supply pressure, a faulty PTR Valve or a faulty thermostat. Turn off the electricity supply and contact Dux on 1300 365 115. High Electricity Bills • Is the Pressure & Temperature Relief Valve discharging too much water? • Is one outlet (such as the shower) using more hot water than you think? See “No Hot Water”.
Owner’s Manual – Proflo Electric Storage Water Heaters Warranty Proflo electric storage water heater Warranty: • 7 Years tank warranty. • 1 year parts and labour. The benefits provided to you by the warranty and replacement guarantee (collectively “Warranty”) are in addition to the guarantees and other rights and remedies available to you under the Australian Consumer Law (“ACL”).
Owner’s Manual – Proflo Electric Storage Water Heaters Warranty instructions and all relevant statutory requirements. • Provide full name, address and contact number. In addition to this Warranty, certain legislation (including the ACL) may give you rights which cannot be excluded, restricted or modified. This Warranty must be read subject to such legislation and nothing in this Warranty has the effect of excluding, restricting or modifying those rights.
Please Register Your Water Heater Electric Storage Water Heaters Please take a moment to fill out your details for warranty registration at: www.dux.com.au/warranty For advice, repairs and service, call: 1300 365 115 (Australia) 0800 729 389 (New Zealand) or use your smartphone to scan this code: Preventative Maintenance Maintaining your hot water system will help extend its lifespan and reduce running costs. Please register for preventative maintenance at: www.dux.com.