2U Series Standalone DVR User’s Manual Version 3.
Table of Contents 1 FEATURES AND SPECIFICATIONS................................................................ 10 1.1 Overview ............................................................................................................................................... 10 1.2 Features ................................................................................................................................................ 10 1.3 Specifications ..................................................
.2 About Front Panel and Real Panel ................................................................................................... 35 3.3 HDD Installation ................................................................................................................................... 35 3.3.1 8 HDD series ................................................................................................................................... 35 3.3.2 4 HDD Series.....................................
.1.5 4.2 Replace Button Battery .................................................................................................................. 47 Manual Record..................................................................................................................................... 47 4.2.1 Live Viewing..................................................................................................................................... 47 4.2.2 Manual record................................
4.9.7 Auto Scan Setup ................................................................................................................................. 69 4.9.8 Activate Auto Scan.............................................................................................................................. 69 4.10 5 Flip .........................................................................................................................................................
5.6.3 Log .................................................................................................................................................. 100 5.6.4 Version ........................................................................................................................................... 101 5.6.5 Online Users .................................................................................................................................. 101 5.7 6 Shutdown ................
.5 Alarm ................................................................................................................................................... 150 7.6 About ................................................................................................................................................... 151 7.7 Log out ................................................................................................................................................ 152 7.
Welcome Thank you for purchasing our DVR! This user’s manual is designed to be a reference tool for the installation and operation of your system. Here you can find information about this series DVR features and functions, as well as a detailed menu tree.
Important Safeguards and Warnings 1.Electrical safety All installation and operation here should conform to your local electrical safety codes. We assume no liability or responsibility for all the fires or electrical shock caused by improper handling or installation. 2.Transportation security Heavy stress, violent vibration or water splash are not allowed during transportation, storage and installation. 3.Installation Keep upwards. Handle with care.
1 FEATURES AND SPECIFICATIONS 1.1 Overview This series product is an excellent digital monitor product designed for security field. It adopts embedded Linux OS to maintain reliable operation. Popular H.264 compression algorithm and G.711 audio compression technology realize high quality, low bit stream. Unique frame by frame play function is suitable for detail analysis. It has various functions such as record, playback, monitor at the same time and can guarantee audio video synchronization.
z Network operation Support network remote real-time monitor, remote record search and remote PTZ control. z Alarm activation function Several relay alarm outputs to realize alarm activation and on-site light control. The alarm input port and output has the protection circuit to guarantee device safety. z Communication port RS485 port can realize alarm input and PTZ control.
Video Input 16-CH composite video input: (NTSC/PAL) BNC (1.0VP- P, 75Ω) 1-ch PAL/NTSC, BNC (1.0VP- P, 75Ω) composite video signal output. 1-ch VGA output. 1-ch HDMI output. Support TV/VGA/HDMI video output at the same time. 4-CH composite video input: (NTSC/PAL) BNC (1.0VP- P, 75Ω) B B 8-CH composite video input: (NTSC/PAL) BNC (1.
Recording Mode Record and playback Recording Length Playback Repeat Way Record Search Playback Mode Various File Switch Ways Multichannel Playback Window Zoom Partial Enlargemen t Backup function Backup Mode Network Function Network control Motion Detection and Alarm Motion Detection Video Loss External Alarm Manual Alarm Control Alarm Input Manual recording, motion detection recording, schedule recording and alarm recording Priority: Manual recording> alarm recording>motion detection recording>sche
Interface Alarm Output Alarm Relay USB Interface Network connection RS485 RS232 System Information Hard Disk Information Data Stream Statistics Log statistics Version On-line user User Management User Manageme nt Password Authenticati on Upgrade Login, Logout and Shutdown General Parameter Power Power Consumptio n Working Temperatur e Working Humidity Air Pressure Dimension Weight Installation Mode 6-channel relay output, including one controllable DC +12V output port. 30VDC 2A,125VAC 2 USB 2.
System Compression Standard Main Processor OS System Resources Interface Input Devices Input Method Shortcut Function Video Compressio n Audio Compressio n Video Input High-performance industrial embedded micro controller Embedded LINUX Multiplex operations: Multiple-channel record, multiple-channel playback and network operation simultaneously User-friendly graphical user interface Front panel, USB mouse, remote control Arabic number, English character, donation and extension Chinese (optional) Copy/pas
Channel Information Audio Hard disk Color Configuratio n Audio Input Audio Output Bidirectional Audio Hard Disk Hard Disk Occupation Recording Mode Record and playback Recording Length Playback Repeat Way Record Search Playback Mode Various File Switch Ways Multichannel Playback Window Zoom Partial Enlargemen t Backup function Backup Mode Network Function Network control Channel name, recording status, screen lock status, video loss status and motion detection status are shown on the bottom left of
Motion Detection and Alarm Motion Detection Video Loss External Alarm Manual Alarm Control Alarm Input Interface Alarm Output Alarm Relay USB Interface Network connection RS485 RS232 System Information Hard Disk Information Data Stream Statistics Log statistics Version On-line user User Management User Manageme nt Password Authenticati on Upgrade Login, Logout and Shutdown General Parameter Power Power Consumptio n Zone setup: support 396((PAL 22×18, NTSC 22×15)) detection zones.
Working Temperatur e Working Humidity Air Pressure Dimension Weight Installation Mode 0℃-+55℃ 10%-90% 86kpa-106kpa 2U standard industrial case. 440(W) x450 (D) x89mm(H) 5.5-6.5KG(Exclude HDD) Desktop/rack installation 1.3.
Image Quality Privacy mask Image Information Channel information, time information and privacy mask zone. Adjust TV output zone suitable to anamorphic video. Channel Lock Cover secret channel with black screen though system is encoding normally. Screen-lock function to prevent unauthorized user seeing secret video. Channel name, recording status, screen lock status, video loss status and motion detection status are shown on the bottom left of display screen.
Multichannel Playback Window Zoom Partial Enlargemen t Backup function Backup Mode Network Function Network control Motion Detection and Alarm Motion Detection Video Loss External Alarm Manual Alarm Control Alarm Input Interface Alarm Output Alarm Relay USB Interface Network connection RS485 RS232 System Information Hard Disk Information Data Stream Statistics Log statistics There is 1/4/9/16-channel playback mode. (It may vary due to different series.
Version On-line user User Management User Manageme nt Password Authenticati on Upgrade Login, Logout and Shutdown General Parameter Power Power Consumptio n Working Temperatur e Working Humidity Air Pressure Dimension Weight Installation Mode Display version information: channel amount, alarm input and output amount, system version and release date.
Audio Compressio n G.711A 32-CH 16-CH composite video composite video input: input: (NTSC/PAL) (NTSC/PAL) BNC (1.0VP- P, BNC (1.0VP- P, 75Ω) 75Ω) 1-ch PAL/NTSC, BNC (1.0VP- P, 75Ω) composite video signal output. 1-ch VGA output. 1-ch HDMI output. Support TV/VGA/HDMI video output at the same time. 4-CH composite video input: (NTSC/PAL) BNC (1.0VP- P, 75Ω) Video Input B 8-CH composite video input: (NTSC/PAL) BNC (1.
Hard disk Bidirectional Audio Hard Disk Hard Disk Occupation Recording Mode Record and playback Recording Length Playback Repeat Way Record Search Playback Mode Various File Switch Ways Multichannel Playback Window Zoom Partial Enlargemen t Backup function Backup Mode Network Function Network control Motion Detection and Alarm Motion Detection Video Loss External Alarm Manual Alarm Control 1-ch audio talk input 200-3000mv 10KΩ(BNC) 1-ch audio talk output 200-3000mv 5KΩ(BNC) 8 built-in SATA port.
Alarm Input Interface Alarm Output Alarm Relay USB Interface Network connection RS485 RS232 System Information Hard Disk Information Data Stream Statistics Log statistics Version On-line user User Management User Manageme nt Password Authenticati on Upgrade Login, Logout and Shutdown General Parameter Power Power Consumptio n Working Temperatur e Working Humidity Air Pressure Dimension Weight 4-ch alarm input 8-ch alarm input 16-ch alarm 16-ch alarm (You can set (You can set input(You can input(Y
Installation Mode Desktop/rack installation 25
2 Overview and Controls This section provides information about front panel and rear panel. When you install this series DVR for the first time, please refer to this part first. 2.1 Front Panel The front panel is shown as in Figure 2-1 and Figure 2-2. Figure 2-1 Figure 2-2 Please refer to the following sheet for front panel button information. Name Icon Function Power button, press this button for three seconds to boot up or shut down DVR.
When playback, click these buttons to control playback bar. Go to previous menu, or cancel current operation. ESC ESC When playback, click it to restore real-time monitor mode. Confirm current operation Enter ENTER Go to default button Go to menu Record REC Slow play Manually stop/start recording, working with direction keys or numeral keys to select the recording channel. Multiple slow play speeds or normal playback.
Up/down direction key. Playback mode, turn the inner dial to realized frame by frame playback. (Only applies to some special versions.) Jog(inner dial) USB port To connect USB storage device, USB mouse. Remote control indication light ACT Remote control indication light Status indication light Status If there is Fn indication light, current status indication light is null.
10 11 12 13 Bidirectional talk output port Network port eSATA port RS232 port 14 15 16 17 18 19 USB port HDMI port Video VGA output Alarm input/alarm output/RS485 port Video CVBS output Video matrix output The 32-channel series DVR rear panel is shown as below. See Figure 2-4. Figure 2-4 Please refer to the following sheet for detailed information.
Figure 2-5 2.4 Remote Control The remote control interface is shown as in Figure 2-6. Please note remote control is not our standard accessory and it is not included in the accessory bag.
Figure 2-6 Serial Number 1 Name Power button Function Click it to boot up or shut down the device. 2 Address Click it to input device number, so that you can control it. 3 Forward 4 Slow play Various forward speeds and normal speed playback. Multiple slow play speeds or normal playback. In playback mode, playback the next video. In playback mode, playback the previous video. In pause mode, click this button to realize normal playback. In normal playback click this button to pause playback.
10 Record 11 Direction keys 12 Confirm /menu key 13 Multiple-window switch 14 Auxiliary key 15 0-9 number key Start or stop record manually In record interface, working with the direction buttons to select the record channel. Click this button for at least 1.5 seconds, system can go to the Manual Record interface. Switch current activated control, go to left or right. In playback mode, it is to control the playback process bar.
In input box, you can select input methods. Left click the corresponding button on the panel you can input numeral/English character (small/capitalized). Here ← stands for backspace button. _ stands for space button. In English input mode: _stands for input a backspace icon and ← stands for deleting the previous character. In numeral input mode: _ stands for clear and ← stands for deleting the previous numeral. When input special sign, you can click corresponding numeral in the front panel to input.
2.6 Virtual Keyboard & Front Panel 2.6.1 Virtual Keyboard The system supports two input methods: numeral input and English character (small and capitalized) input. Move the cursor to the text column, the text is shown as blue, input button pops up on the right. Click that button to switch between numeral input and English input (capitalized and small), Use > or < to shift between small character and capitalized character. 2.6.2 Front Panel Move the cursor to the text column.
3 Installation and Connections Note: All the installation and operations here should conform to your local electric safety rules. 3.1 Check Unpacked DVR When you receive the DVR from the forwarding agent, please check whether there is any visible damage. The protective materials used for the package of the DVR can protect most accidental clashes during transportation. Then you can open the box to check the accessories.
7. Unfasten the HDD power 8. Insert the HDD power 9. Use the special data cable to cable. cable. connect the HDD and the SATA port. Close the chassis and fix the screws to secure firmly. Important If the HDD amount is less than four, you do not need to install the HDD bracket. When there is a bracket, please make sure the installation direction of HDDs is the same. 3.3.2 4 HDD Series This series DVR max supports 4 SATA HDDs. Please use HDD of 7200rpm or higher. It has no requirement for HDD capacity.
The DVR occupies 2 rack units of vertical rack space. z Use twelve screws to fix the unit z Please make sure the indoor temperature is below 35℃ (95°f). z Please make sure there is 15cm (6 inches) space around the device to guarantee sound ventilation. z Please install from the bottom to the top. z If there are more accessories connected in the rack, please take precaution measures in case the rack power is overload. 3.
Figure 3-1 3.6.2 Connecting Video Output Video output includes a BNC(PAL/NTSC 1.0VP-P ,75Ω)output ,a VGA output and HDMI output. System supports BNC, VGA and HDMI output at the same time. See Figure 3-2 When you are using pc-type monitor to replace the monitor, please pay attention to the following points: z To defer aging, do not allow the pc monitor to run for a long time. z Regular demagnetization will keep device maintain proper status. z Keep it away from strong electromagnetic interference devices.
Important Please note there is a series product does not support audio function. For this series product user, you can skip the following contents. 3.7.1 Audio Input These series products audio input port adopt BNC port, matrix and loop use BNC port. Device supports bidirectional talk via BNC. Due to high impedance of audio input, please use active sound pick-up. See Figure 3-3. Audio transmission is similar to video transmission.
Figure 3-4 3.8 Alarm Input and Output Connection Please refer to the following sheet for alarm input and output connection. See Figure 3-5. X287H X Figure 3-5 There are two alarm input types for you to select: normal open (NO) and normal close (NC). 1. Alarm input a. Please make sure alarm input mode is grounding alarm input. b. Grounding signal is needed for alarm input. c. Alarm input needs the low level voltage signal. d. Alarm input mode can be either NC (normal Open) or NO (Normal Close) e.
The alarm output port should not be connected to high power load directly (It shall be less than 1A) to avoid high current which may result in relay damage. Please use the co contactor to realize the connection between the alarm output port and the load. 3. How to connect PTZ decoder a. Ensure the decoder has the same grounding with DVR, otherwise you may not control the PTZ. Shielded twisted wire is recommended and the shielded layer is used to connect to the grounding. b. Avoid high voltage.
3.8.2 Alarm Input Port Please refer to the following sheet for more information. z 4/8/16-ch grounding alarm inputs. (Normal open or Normal close type) z Please parallel connect COM end and GND end of the alarm detector (Provide external power to the alarm detector). z Please parallel connect the Ground of the DVR and the ground of the alarm detector.
Length of close time 3ms max Longevity Mechanical 50×106 times (3Hz) Electrical 200×103 times (0.5Hz) Temperature -40℃ ~+70℃ 3.9 RS232 You can connect the DVR with POS or Keyboard through RS232. With POS system, the DVR can communicate through RS232 and network. For the POS system, the DVR can integrate the text content and even search the record through the info. The series DVR also support NKB operation.
Figure 3-9 44
4 Overview of Navigation and Controls Before operation, please make sure: z You have properly installed HDD and all the cable connections. z The provided input power and the device power are matched. z The external power shall be: AC90~264V 50+2% Hz z Always use the stable current, if necessary UPS is a best alternative measure. 4.1 Login, Logout & Main Menu 4.1.1 Login After system booted up, system pops up the startup wizard. Click the Cancel button; you can go to the system login interface.
Figure 4-2 4.1.2 Main Menu After you logged in, the system main menu is shown as below. See Figure 4-3. There are total six icons: search, information, setting, backup, advanced and shutdown. You can move the cursor to highlight the icon, and then double click mouse to enter the submenu. Figure 4-3 4.1.3 Logout There are two ways for you to log out. One is from menu option: In the main menu, click shutdown button, you can see an interface is shown as below. See Figure 4-4.
The other ways is to press power button on the front panel for at least 3 seconds, system will stop all operations. Then you can click the power button in the rear panel to turn off the DVR. 4.1.4 Auto Resume after Power Failure The system can automatically backup video and resume previous working status after power failure. 4.1.5 Replace Button Battery Please make sure to use the same battery model if possible. We recommend replace battery regularly (such as one-year) to guarantee system time accuracy.
There are two ways for you to go to manual record menu. z Right click mouse or in the main menu, Advanced->Manual Record. z In live viewing mode, click record button in the front panel or record button in the remote control. Manual record menu is shown as in Figure 4-7. 4.2.2.2 Basic operation There are three statuses: schedule/manual/stop. Please highlight icon“○” to select corresponding channel. z Manual: The highest priority. After manual setup, all selected channels will begin ordinary recording.
Figure 4-9 z All channel manual record Please highlight “ALL” after “Manual.” See Figure 4-10. When system is in manual recording, all scheduled set up you have set in will be null ((Main menu->Setting->Schedule)). You can see indication light in front panel turns on, system begins manual record now. Figure 4-10 4.2.2.5 Stop all channel recording Please highlight “ALL” after “Stop”. See Figure 4-11.
2 1 3 4 11 7 8 12 6 5 10 9 Figure 4-12 Please refer to the following sheet for more information. SN 1 2 Name Display window Search type 3 Calendar 4 Playback mode and channel selection pane. Function zHere is to display the searched picture or file. zSupport 1/4/9/16-window playback. zHere you can select to search the picture or the recorded file. zWhen there is displayed picture on the left pane, you can set the corresponding setup zThe blue highlighted date means there is picture or file.
5 File list switch button 6 Card number search zDouble click it, you can view the picture/record file list of current day. zThe file list is to display the first channel of the record file. zThe system can display max 128 files in one time. Use the S/T or the mouse to view the file. Select one item, and then double click the mouse or click the ENTER button to playback. zYou can input the period in the following interface to begin accurate search.
10 Backup 11 Clip 12 Record type Select the file(s) you want to backup from the file list. System max supports files from four channels. Then click the backup button, now you can see the backup menu. Click the start button to begin the backup operation. Check the file again you can cancel current selection. System max supports to display 32 files from one channel. zIt is to edit the file. ●Please play the file you want to edit and then click this button when you want to edit.
Please highlight icon to select the corresponding function. After completing all the setups please click save button, system goes back to the previous menu. At the bottom of the menu, there are color bars for your reference. Green color stands for regular recording, yellow color stands for motion detection and red color stands for alarm recording. The white means the MD and alarm record is valid.
Figure 4-14 Playback or search in the redundant disk. There are two ways for you to playback or search in the redundant disk. z Set redundant disk(s) as read-only disk or read-write disk (Main menu->Advanced->HDD management). See Figure 4-14.System needs to reboot to get setup activated. Now you can search or playback file in redundant disk. z Dismantle the disk and play it in another PC. 4.4.2 Snapshot 4.4.2.
Figure 4-15 4.4.2.2 Activation Snapshot Please follow the steps listed below to enable the activation snapshot function. After you enabled this function, system can snapshot when the corresponding alarm occurred. z In Encode interface, click snapshot button to input snapshot mode, size, quality and frequency. z In General interface please input upload interval. z In Detect interface please enable snapshot function for specified channels.
Please note the activation snapshot has the higher priority than schedule snapshot. If you have enabled these two types at the same time, system can activate the activation snapshot when alarm occurs, and otherwise system just operates the schedule snapshot. 4.4.3 Image FTP In Network interface, you can set FTP server information. Please enable FTP function and then click save button. See Figure 4-17. Please boot up corresponding FTP server. Please enable schedule snapshot (Chapter 4.4.2.
Select a file and then click here to view image content. Select search engine here You can see result here. Double click file name, you can view the image content. There are max 100 files in one Figure 4-19 page. Click here to view more. 4.5 Detect 4.5.1 Go to Detect Menu In the main menu, from Setting to Detect, you can see motion detect interface. See Figure 4-20.There is three detection types: motion detection, video loss, camera masking. 4.5.2 Motion Detect Detection menu is shown as below.
z z z z Show message: System can pop up a message to alarm you in the local host screen if you enabled this function. Alarm upload: System can upload the alarm signal to the network (including alarm centre) if you enabled current function. Send email: System can send out email to alert you when alarm occurs. PTZ activation: Here you can set PTZ movement when alarm occurs. Such as go to preset, tour &pattern when there is an alarm. Click “select” button, you can see an interface is shown as in Figure 4-22.
Figure 4-21 Figure 4-22 Figure 4-23 Figure 4-24 4.5.
In Figure 4-20, select video loss from the type list. You can see the interface is shown as in Figure 4-25.This function allows you to be informed when video loss phenomenon occurred. You can enable alarm output channel and then enable show message function. Tips: You can enable preset activation operation when video loss occurs. Please refer to chapter 4.5.2 motion detection for detailed information. Figure 4-25 4.5.
4.6 Alarm Setup and Alarm Activation Before operation, please make sure you have properly connected alarm devices such as buzzer. 4.6.1 Go to alarm setup interface In the main menu, from Setting to Alarm, you can see alarm setup interface. See Figure 4-27. 4.6.2 Alarm setup Alarm interface is shown as below. See Figure 4-27. z Alarm in: Here is for you to select channel number. z Event type: There are two types. One is local input and the other is network input. z Type: normal open or normal close.
Figure 4-27 Figure 4-28 Figure 4-29 Figure 4-30 62
4.7 Backup DVR support USB device backup and network download. Here we introduce USB backup and eSATA backup. You can refer to Chapter 7 Web Client Operation for network download backup operation. 4.7.1 Detect Device Click backup button, you can see an interface is shown as in Figure 4-31. Here is for you to view devices information. You can view backup device name and its total space and free space. The device includes USB burner, flash disk, SD card, portable HDD and eSATA. Figure 4-31 4.7.
Click backup button, system begins burning. At the same time, the backup button becomes stop button. You can view the remaining time and process bar at the left bottom. See Figure 4-33. Figure 4-33 The file name format usually is: SN_CH+channel number+time Y+M+D+H+M+S. In the file name, the YDM format is the same as you set in general interface. (Main Menu ->Setting >General).File extension name is .dav. Tips: During backup process, you can click ESC to exit current interface for other operation.
z z z z z Address: default address is 1. Baud rate: select corresponding baud rate. Default value is 9600. Data bits: select corresponding data bits. Default value is 8. Stop bits: select corresponding stop bits. Default value is 1. Parity: there are three options: odd/even/none. Default setup is none. Figure 4-34 After completing all the setting please click save button. In one window display mode, right click mouse (click “Fn” Button in the front panel or click “Fn” key in the remote control).
Figure 4-36 In Figure 4-36, please click direction arrows (See Figure 4-37) to adjust PTZ position. There are total 8 direction arrows. Figure 4-37 4.8.3 3D Intelligent Positioning Key In the middle of the eight direction arrows, there is a 3D intelligent positioning key. SeeFigure 4-38. Please make sure your protocol supports this function and you need to use mouse to control. Click this key, system goes back to the single screen mode. Drag the mouse in the screen to adjust section size.
Figure 4-39 In Figure 4-36, click page switch button, the interface is shown as in Figure 4-40. Here you can activate the following functions: z Preset z Tour z Pattern z Auto scan z Auto pan z Flip z Reset z Page switch X328H Figure 4-40 Note: z Preset, tour and pattern all need the value to be the control parameter. You can define it as you require. z You need to refer to your speed dome user’s manual for Aux definition. In some cases, it can be used for special process.
Figure 4-41 4.9.2 Activate Preset In Figure 4-40, please input preset number in the No. blank, and click preset button. 4.9.3 Patrol setup (Tour Setup) In Figure 4-38, click patrol button. The interface is shown as in Figure 4-42.Input preset number and add this preset to a patrol (tour). For each patrol (tour), you can input max 80 presets. Figure 4-42 4.9.4 Activate Patrol (tour) In Figure 4-39, input patrol (tour) number in the No. blank and click patrol button X341H 4.9.
4.9.7 Auto Scan Setup In Figure 4-38, click border button. The interface is shown as in Figure 4-43. Please go to Figure 4-35, use direction arrows to select camera left limit Then please go to Figure 4-43 and click left limit button Repeat the above procedures to set right limit. X347H X349H X348H X349H X350H X Figure 4-44 4.9.8 Activate Auto Scan In Figure 4-40, click “Auto Scan” button, the system begins auto scan. Correspondingly, the auto scan button becomes Stop button.
5 Understanding of Menu Operations and Controls 5.1 Menu Tree This series DVR menu tree is shown as below. Backup Information HDD Info BPS Log Version Online Users Setting General Encode Schedule RS232 Network Alarm Detect Pan/ Tilt/Zoom Display Default Menu Search Advanced HDD Management Alarm Output Abnormity Manual Record Account Auto Maintain TV Adjust Video Matrix Title Overlay Config Backup Shutdown 5.2 Main Menu After you logged in, the system main menu is shown as below. See Figure 5-1.
Figure 5-1 5.3 Setting In main menu, highlight setting icon and double click mouse. System setting interface is shown as below. See Figure 5-2. Figure 5-2 5.3.1 General General setting includes the following items. See Figure 5-3. z System time: Here is for you to set system time z Date format: There are three types: YYYYY-MM-DD: MM-DD-YYYYY or DD-MM-YYYY. z Date separator: There are three denotations to separate date: dot, beeline and solidus. z DST: Here you can set DST time and date.
z z z z z z while the next HDD is no empty, then system stops recording, If the current HDD is full and then next HDD is not empty, then system overwrites the previous files. Pack duration: Here is for you to specify record duration. The value ranges from 60 to 120 minutes. Default value is 60 minutes. DVR No: When you are using one remote control (not included in the accessory bag) to control several DVRs, you can give a name to each DVR for your management.
5.3.2 Encode Encode setting includes the following items. See Figure 5-6. Please note some series do not support extra stream. z Channel: Select the channel you want. z Type: Please select from the dropdown list. There are three options: regular/motion detect/alarm. You can set the various encode parameters for different record types. z Compression: System supports H.264. z Resolution: System supports various resolutions, you can select from the dropdown list.
Figure 5-6 Figure 5-7 5.3.3 Schedule Please refer to chapter 4.4 schedule. 5.3.4 RS232 RS232 interface is shown as below. There are five items. See Figure 5-8. z Function: There are various devices for you to select. Console is for you to use the COM or mini-end software to upgrade or debug the program. The control keyboard is for you to control the device via the special keyboard. Transparent COM (adapter) is to connect to the PC to transfer data directly. Protocol COM is for card overlay function.
Figure 5-8 5.3.5 Network Here is for you to input network information. See Figure 5-9. z IP address: Here you can input IP address. z DHCP: It is to auto search IP. When enable DHCP function, you can not modify IP/Subnet mask /Gateway. These values are from DHCP function. If you have not enabled DHCP function, IP/Subnet mask/Gateway display as zero. You need to disable DHCP function to view current IP information. Besides, when PPPoE is operating, you can not modify IP/Subnet mask /Gateway.
Figure 5-9 5.3.5.1 Advanced Setup Advanced setup interface is shown as in Figure 5-10. Please draw a circle to enable corresponding function and then double click current item to go to setup interface. Figure 5-10 5.3.5.2 IP Filter IP filter interface is shown as in Figure 5-11. You can add IP in the following list. The list supports max 64 IP addresses. Please note after you enabled this function, only the IP listed below can access current DVR.
5.3.5.3 NTP Setup You need to install SNTP server (Such as Absolute Time Server) in your PC first. In Windows XP OS, you can use command “net start w32time” to boot up NTP service. NTP setup interface is shown as in Figure 5-12. z Host IP: Input your PC address. z Port: This series DVR supports TCP transmission only. Port default value is 123. z Update interval: minimum value is 1. Max value is 65535. (Unit: minute) z Time zone: select your corresponding time zone here.
Figure 5-13 Here you can set a multiple cast group. Please refer to the following sheet for detailed information. z IP multiple cast group address -224.0.0.0-239.255.255.255 -“D” address space z The higher four-bit of the first byte=”1110” z Reserved local multiple cast group address -224.0.0.0-224.0.0.255 -TTL=1 When sending out telegraph -For example 224.0.0.1 All systems in the sub-net 224.0.0.2 All routers in the sub-net 224.0.0.4 DVMRP router 224.0.0.5 OSPF router 224.0.0.
Figure 5-14 5.3.5.6 DDNS Setup DDNS setup interface is shown as in Figure 5-15. You need a PC of fixed IP in the internet and there is the DDNS software running in this PC. In other words, this PC is a DNS (domain name server). In network DDNS, please select DDNS type and highlight enable item. Them please input your PPPoE name you get from you IPS and server IP (PC with DDNS ) . Click save button and then reboot system. Click save button, system prompts for rebooting to get all setup activated.
The UPNP protocol is to establish a mapping relationship between the LAN and the WAN. Please input the router IP address in the LAN in Figure 5-9. Double click the UPNP item in Figure 5-9, you can see the following interface. See Figure 5-16. z UPNP on/off :Turn on or off the UPNP function of the device. z Status: When the UPNP is offline, it shows as “Unknown”. When the UPNP works it shows “Success” z Router LAN IP: It is the router IP in the LAN. z WAN IP: It is the router IP in the WAN.
Figure 5-17 5.3.5.8 Email The email interface is shown as below. See Figure 5-18. z SMTP server: Please input your email SMTP server IP here. z Port: Please input corresponding port value here. z User name: Please input the user name to login the sender email box. z Password: Please input the corresponding password here. z Sender: Please input sender email box here. z Title: Please input email subject here. System support English character and Arabic number. Max 32-digit.
Figure 5-18 Figure 5-19 5.3.5.9 FTP You need to download or buy FTP service tool (such as Ser-U FTP SERVER) to establish FTP service. Please install Ser-U FTP SERVER first. From “start” -> “program” -> Serv-U FTP Server -> ServU Administator. Now you can set user password and FTP folder. Please note you need to grant write right to FTP upload user. See Figure 5-20.
Figure 5-20 You can use a PC or FTP login tool to test setup is right or not. For example, you can login user ZHY to FTP://10.10.7.7 and then test it can modify or delete folder or not. See Figure 5-21. H140TU UTH Figure 5-21 System also supports upload multiple DVRs to one FTP server. You can create multiple folders under this FTP. In Figure 5-9, select FTP and then double click mouse. You can see the following interface. See Figure 5-22.
Figure 5-22 Figure 5-23 5.3.5.10 Alarm Centre This interface is reserved for you to develop. 5.3.6 Alarm Please refer to chapter 4.6 Alarm Setup and Activation. 5.3.7 Detect Please refer to chapter 4.5 Detect. 5.3.8 Pan/Tilt/Zoom The pan/tilt/zoom setup includes the following items. Please select channel first. See Figure 5-24. z Protocol: Select corresponding PTZ protocol such as PELCOD. z Address: input corresponding PTZ address. z Baud rate: Select baud rate. z Data bit: Select data bit.
Figure 5-24 5.3.9 Display Display setup interface is shown as below. See Figure 5-25. z Transparency: Here is for you to adjust transparency. The value ranges from 128 to 255. z Channel name: Here is for you to modify channel name. System max support 25-digit (The value may vary due to different series). Please note all your modification here only applies to DVR local end. You need to open web or client end to refresh channel name.
Figure 5-25 In Figure 5-25, click modify button after channel. You can see an interface is shown as in Figure 5-26. Please note all your modification here applies to local end only. You need to refresh web or client-end to get the latest channel name. System max support 25-digital character. Figure 5-26 In tour mode, you can see the following interface. On the right corner, right click mouse or click shift button, you can control the tour.
Click default icon, system pops up a dialogue box. You can highlight to restore default factory setup. See Figure 5-26. z Select all z General z Encode z Schedule z RS232 z Network z Alarm z Detect z Pan/tilt/zoom z Display z Channel name X381H Please highlight icon to select the corresponding function. After all the setups please click save button, system goes back to the previous menu.
Figure 5-29 5.5.1 HDD Management Here is for you to view and implement hard disk management. See Figure 5-30. You can see current HDD type, status, capacity and record time. When HDD is working properly, system is shown as O. When HDD error occurred, system is shown as X. z Alarm set: Click alarm set button, the interface is shown as below. See Figure 5-31. (This interface is just like the abnormity setup). Please refer to chapter 5.5.2 for detailed information.
Please highlight icon to select the corresponding function. Figure 5-31 For the HDD group setup operation, please note: z Each channel’s records can be stored into the specified HDD Group. z Each HDD Group is corresponding to several hard disks, while one hard disk is only included in one HDD Group. z Each channel is only corresponding with one HDD Group, while one HDD Group can store records from several channels.
Figure 5-32 In Figure 5-33, you can see the 6th and 7th position hard disks both belong to HDD Group 2. Important Once you change the HDD Group settings, system will pack the records and snapshots, and then reboot. Figure 5-33 Channels Setting Click the button named with “Channels Settings” at the top right corner of the Figure 5-30, system will pop up an interface shown as in Figure 5-34.
The Figure 5-34 and Figure 5-35 show that channels 1 to 16 are associated to HDD Group NO 1, and channels 17 to 32 are associated to HDD Group NO 2. Therefore the records of channels 1 to 16 are stored into the hard disk(s) which belong to HDD Group NO 1, and the records of channels 17 to 32 are stored into the hard disk(s) which belong to HDD Group NO 2. Important Once you change the HDD Group settings, system will pack the records and snapshots, and then reboot. Figure 5-34 Figure 5-35 5.5.
Figure 5-36 5.5.3 Alarm Output Here is for you to set proper alarm output. Please highlight icon to select the corresponding alarm output. After all the setups please click OK button, system goes back to the previous menu. See Figure 5-37. Figure 5-37 5.5.4 Manual Record Please refer to chapter 4.2.2 manual record. 5.5.5 Account Here is for you to implement account management. See Figure 5-38. Here you can: z Add new user z Modify user z Add group z Modify group z Modify password.
For the user account name and the user group, the string max length is 6-byte. The backspace in front of or at the back of the string is invalid. There can be backspace in the middle. The string includes the valid character, letter, number, underline, subtraction sign, and dot. z System account adopts two-level management: group and user. No limit to group or user amount. z For group or user management, there are two levels: admin and user. z The user name and group name can consist of eight bytes.
Figure 5-39 5.5.5.2 Add/Modify Group Click add group button, the interface is shown as below. See Figure 5-40. Here you can input group name and then input some memo information if necessary. There are total 60 rights such as control panel, shut down, real-time monitor, playback, record, record file backup, PTZ, user account, system information view, alarm input/output setup, system setup, log view, clear log, upgrade system, control device and etc. The modify group interface is similar to the Figure 5-40.
The modify user interface is similar to Figure 5-41. Figure 5-41 5.5.6 Auto Maintain Here you can set auto-reboot time and auto-delete old files setup. You can set to delete the files for the specified days. See Figure 5-42. You can select proper setup from dropdown list. After all the setups please click save button, system goes back to the previous menu. Figure 5-42 5.5.7 TV Adjust Here is for you to adjust TV output setup. See Figure 5-43. Please drag slide bar to adjust each item.
Figure 5-43 5.5.8 Video Matrix Here you can set matrix output channel and its interval. See Figure 5-44. Figure 5-44 5.5.9 Card Overlay The card overlay function is for financial areas. It includes Sniffer, information analysis and title overlay function. The Sniffer mode includes COM and network. 5.5.9.1 COM Type The COM interface is shown as below. See Figure 5-45. z Protocol: Please select from the dropdown list. z Setting: Click COM setting button, the interface is shown as in RS232 interface.
Figure 5-45 5.5.9.2 Network Type The network type interface is shown as below. See Figure 5-46. Here we take the ATM/POS protocol to continue. There are two types: with or without the protocol according to client’s requirements. With the protocol For ATM/POS with the protocol, you just need to set the source IP, destination IP (sometimes you need to input corresponding port number). Figure 5-46 Without the protocol For the ATM/POS without the protocol, the interface is shown as in Figure 5-47.
Figure 5-47 Click Data button you can see an interface is shown as in Figure 5-48. Here you can set offset value, length, title according to your communication protocol and data package. . Figure 5-48 5.5.10 Config File Backup The configuration file backup interface is shown as below. See Figure 5-49. This function allows you to copy current system configuration to other devices.
5.6 Information Here is for you to view system information. There are total five items: HDD (hard disk information), BPS (data stream statistics), Log and version, and online user. See Figure 5-50. Figure 5-50 5.6.1 HDD Information Here is to list hard disk type, total space, free space, video start time and status. See See Figure 5-51.○ means current HDD is normal. X means there is error. - means there is no HDD. X391H If disk is damaged, system shows as “?”.
Tips: Please click Fn button or left click mouse to view HDD record time and HDD type and time. 5.6.2 BPS Here is for you to view current video data stream (KB/s) and occupied hard disk storage (MB/h). See Figure 5-52. Figure 5-52 5.6.3 Log Here is for you to view system log file. System lists the following information. See Figure 5-53. Log types include system operation, configuration operation, data management, alarm event, record operation, log clear and etc.
Click the Details button or double click the log item, you can view the detailed information. See Figure 5-54. Figure 5-54 5.6.4 Version Here is for you to view some version information. See Figure 5-55. z Channel z Alarm in z Alarm out z System version: z Build Date Figure 5-55 5.6.5 Online Users Here is for you manage online users. See Figure 5-56. You can disconnect one user or block one user if you have proper system right. Max disconnection setup is 65535 seconds.
Figure 5-56 5.7 Shutdown Double click shutdown button, system pops up a dialogue box for you to select. See Figure 5-57 z Logout menu user: log out menu. You need to input password when you login the next time. z Restart application: reboot DVR. z Shutdown: system shuts down and turns off power. z Restart system: system begins rebooting. z Switch user: you can use another account to log in.
6 About Auxiliary Menu 6.1 Go to Pan/Tilt/Zoom Menu In the one-window surveillance mode, right click mouse (click “fn” Button in the front panel or click AUX key in the remote control). The interface is shown as below: See Figure 6-1. X397H X Figure 6-1 Click Pan/Tilt/Zoom, the interface is shown as in Figure 6-2. Here you can set the following items: z Zoom z Focus z Iris Please click icon and to adjust zoom, focus and Iris.
In the middle of the eight direction arrows, there is a 3D intelligent positioning key. See Figure 6-4 . Please make sure your protocol supports this function and you need to use mouse to control. Click this button, system goes back to the single screen mode. Drag the mouse in the screen to adjust section size. X401H X Figure 6-4 Here is a sheet for you reference. Name Function function key Near Zoom Near Focus Iris close Shortcut key Function key │_ W function Shortcut key ►│ f Far Far Open 6.
Figure 6-6 6.2.1 Preset Setup Note: The following setups are usually operated in the Figure 6-2, Figure 6-5 and Figure 6-6. In Figure 6-2, use eight direction arrows to adjust camera to the proper position. In Figure 6-5, click preset button and input preset number. The interface is shown as in Figure 6-7. Add this preset to one patrol number X405H X408H X X406H X X407H X X X409H X X410H X Figure 6-7 6.2.2 Activate Preset In Figure 6-6 please input preset number in the No.
You can memorize all these setups as pattern 1. Figure 6-9 6.2.6 Activate Pattern Function In Figure 6-6 input mode value in the No. blank, and click pattern button. X419H X 6.2.7 Border Setup In Figure 6-5, click border button. The interface is shown as in Figure 6-10. Please go to Figure 6-2, use direction arrows to select camera left limit, and then please go to Figure 6-10 and click left limit button Repeat the above procedures to set right limit. X420H X X421H X42H X423H X X X Figure 6-10 6.
Figure 6-11 107
7 WEB CLIENT OPERATION There might be slightly difference in the interface due to different series. 7.1 Network Connection Before web client operation, please check the following items: z Network connection is right z DVR and PC network setup is right. Please refer to network setup(main menu->setting>network) z Use order ping ***.***.***.***(* DVR IP address) to check connection is OK or not. Usually the return TTL value should be less than 255. z Open the IE and then input DVR IP address.
Figure 7-2 After installation, the interface is shown as below. See Figure 7-3. Please input your user name and password. Default factory name is admin and password is admin. X430H X Note: For security reasons, please modify your password after you first login. Figure 7-3 After you logged in, you can see the main window. See Figure 7-6. This main window can be divided into the following sections.
z z z z z Section 1: there are five function buttons: configuration (chapter 7.3), search (chapter 7.4), alarm (chapter 7.5), about (chapter 7.6), log out (chapter 7.7). Section 2: there are channel number and three function buttons: start dialog and local play, refresh. Section3: there are PTZ (chapter 7.2.2), color (chapter 7.2.3) button and you can also select picture path and record path. Section 4:real-time monitor window. Please note current preview window is circled by a green rectangle zone.
7.2.1 Real-time Monitor In section 2, left click the channel name you want to view, you can see the corresponding video in current window. On the top left corner, you can view device IP, channel number, network monitor bit stream. 1 2 3 Figure 7-7 On the top right corer, there are six unction buttons. See Figure 7-8. X43H 1 2 3 4 5 X 6 Figure 7-8 1: Digital zoom: Click this button and then left drag the mouse in the zone to zoom in. right click mouse system restores original status.
Figure 7-9 Open All You can click it to open all channels. Refresh You can use button to refresh camera list. Start Dialogue You can click this button to enable audio talk. Click 【▼】 to select bidirectional talk mode. There are two options: DEFAULT/G711a. Please note, the audio input port from the device to the client-end is using the first channel audio input port. During the bidirectional talk process, system will not encode the audio data from the 1channel.
Figure 7-10 7.2.2 PTZ Before PTZ operation, please make sure you have properly set PTZ protocol. (Please refer to chapter 7.3.2 Setting-> Pan/Tilt/Zoom). Click PTZ button, the interface is shown as in Figure 7-11. X437H X 3D Intelligent Positioning Key You can click this icon to display or hide the PTZ control platform. Figure 7-11 7.2.2.1 Direction key and 3D positioning key In Figure 7-10, there are eight direction keys.
Click 3D intelligent positioning key, system goes back to the single screen mode. Drag the mouse in the screen to adjust section size. It can realize PTZ automatically. 7.2.2.2 Speed System supports eight-level speed. You can select from the dropdown list. Speed 2 is faster than speed 1. 7.2.2.3 Zoom/Focus/Iris Here is a sheet for you reference.
You can select the assistant item from the dropdown list. See Figure 7-13. X43H X 7.2.2.9 Matrix This series product supports matrix extension function. You can control the video input and output switch 7.2.2.10 Light and wiper If your PTZ protocol supports the light and wiper control function. You can enable/disable the light or the wiper. Figure 7-13 7.2.3 Color Click color button in section 3, the interface is shown as Figure 7-14.
Figure 7-15 Click picture path button, you can see an interface is shown as in Figure 7-16. Please click choose button to modify path. X47H X Figure 7-16 Click record path button, you can see an interface is shown as in Figure 7-17. Please click choose button to modify path. X48H X Figure 7-17 Click reboot button, system pops up the following dialogue box. See Figure 7-18, Please click OK to reboot.
Figure 7-19 7.3.1.2 HDD information Here you can view local storage status and network status including, free capacity and total capacity. See Figure 7-20. X450H X Figure 7-20 7.3.1.3 Log Here you can view system log. See Figure 7-21.
Figure 7-21 Click backup button, the interface is shown as in Figure 7-22. X452H X Figure 7-22 Please refer to the following sheet for log parameter information. Parameter Function Type Log types include: system operation, configuration operation, data management, alarm event, record operation, user management, log clear and file operation. You can select log type from the drop down list and then click search button to view the list. Search Start time Please input start time here.
Parameter Function Backup You can click this button to backup log files to current PC. 7.3.2 System Configuration Please click save button to save your current setup. 7.3.2.1 General Setup Here you can set system time, record length, video format and etc. See Figure 7-23 X453H X.
Please refer to the following sheet for detailed information. Parameter Function System Time Here is for you to modify system time. Please click Save button after your completed modification Sync PC You can click this button to save the system time as your PC current time. Data Format Here you can select data format from the dropdown list. Data Separator Please select separator such as – or /. Time Format There are two options: 24-H and 12-H.
Figure 7-26 Figure 7-27 Please refer to the following sheet for detailed information. Parameter Function Channel Here is for you to select a monitor channel. Channel Name Here is to display current channel name. You can modify it. Compression H.264 Main Stream It includes main stream, motion stream and alarm stream. You can select different encode frame rates form different recorded events. System supports active control frame function (ACF). It allows you to record in different frame rates.
Parameter Function Audio/Video For the main stream, recorded file only contains video by default. You need to draw a circle here to enable audio function. For extra stream, you need to draw a circle to select the video first and then select the audio if necessary. Resolution For 4 HDD series: Main stream resolution supports D1/CIF/QCIF. Extra stream of channel 1 to channel 16 support QCIF only. For 8 HDD series, there is one model : One series main stream resolution supports D1/HD1/BCIF/CIF/QCIF.
Parameter Function Time Title z You can enable this function so that system overlays time information in video window. z OSD transparent value ranges from 0 to 255. 0 means complete transparent. Please note OSD transparent setup is form special series only. z You can use the mouse to drag the time tile position. z You can enable this function so that system overlays channel information in video window. z OSD transparent value ranges from 0 to 255. 0 means complete transparent.
Figure 7-29 Figure 7-30 Please refer to the following sheet for detailed information. Parameter Function Channel Please select a channel first. Pre-record Please input pre-record value here. System can record the three to five seconds video before activating the record operation into the file. (Depends on data size).
Parameter Function Setup z In Figure 7-29, click set button, you can go to the corresponding setup interface. z Please set schedule period and then select corresponding record or snapshot type: schedule/snapshot, motion detection/snapshot, and alarm/snapshot. z Please select date (Current setup applies to current day by default. You can draw a circle before the week to apply the setup to the whole week.
Parameter Function Data Bit Keyboard: COM control protocol. You can use keyboard to control DVR via COM. The value ranges from 5 to 8. Stop Bit There are three options: 1/2. Baud Bit You can select corresponding baud bit here. Parity There are five options: none/odd/even/space/mark. System default setup is: z Function: Console. z Data bit: 8 z Stop bit: 1 z Baud bit: 115200 z Parity: None. 7.3.2.5 Network Network interface is shown as in Figure 7-32.
Parameter Function UDP Port Default value is 37778. Max Connection Network user max amount. The value ranges from 0 to 20. O means there is no user can access current device. Remote Host Multiple cast group z Set MULCAST address and port. z Enable MULCAST function. PPPOE z Input the PPPoE user name and password you get from the IPS (internet service provider) and enable PPPoE function. Please save current setup and then reboot the device to get the setup activated.
Parameter Function Sender Sender email address. Subject Input email subject here. Max 32-digit. Address Input receiver email address here. Max input three addresses. Support SSL encryption mailbox. Please check the box here to enable this function. This function allows the system to send out the test email to check the connection is OK or not. Please check the above box to enable this function and then set the corresponding interval. System can send out the email regularly as you set here.
Parameter Function Interval z Device sends out alive signal to the server regularly. z You can set interval value between the device and DDNS server here. NAS NAS interface is shown as in Figure 7-35. Please make sure your DVR support this function. X465H X Figure 7-35 Please refer to the following sheet for detailed information. Parameter Function NAS enable Please select network storage protocol and then enable NAS function. Server IP Input remote storage server IP address.
Parameter Function Refresh Click this button to get device latest configuration information. NTP The NTP interface is shown as in Figure 7-36. Here you can realize network time synchronization. Please enable current function and then input server IP, port number, time zone and update interval. Please note the SNTP supports TCP transmission only and its port shall be 123.The update interval ranges from 1 to 65535. Default value is 10 minutes.
Middle Atlantic Time GMT-2 Alarm Centre Alarm centre interface is shown as below. See Figure 7-37. This interface is for you to develop. The alarm signal can be uploaded to the alarm centre when there is local alarm. Please set the corresponding parameters such as server IP, port and etc. The system can send out the data as the protocol defined to the client-end. Figure 7-37 Advanced The advanced interface is shown as in Figure 7-38. z Multiple cast Please refer to chapter 5.3.5.
Figure 7-38 UNPN Go to the UPnP interface, you can see an image is shown as in Figure 3-39. It allows you to establish the mapping relationship between the LAN and the public network. Here you can also add, modify or remove UPnP item. Figure 7-39 UNPN 7.3.2.6 Alarm Alarm setup interface is shown as in Figure 7-40. Please make sure you have connected the corresponding alarm output device such as the light, buzzer and etc.
Figure 7-40 Figure 7-41 Please refer to the following sheet for detailed information. Parameter Function Event It includes local alarm/network alarm. Type Local alarm: Device detects alarm from input port. Network: Device detects alarm from network. Alarm in Select corresponding alarm channel. Enable You need to draw a circle here so that system can detect the alarm signal. Type There are two options: normal open and normal close. NO becomes activated in low voltage, NC becomes activated in high voltage.
Parameter Period Anti-dither Normal Out Alarm Latch Show message Buzzer Alarm upload Record Channel Record Latch Email Tour PTZ activation Capture Copy Save Refresh Function Alarm record function becomes activated in the specified periods. There are six periods in one day. Please draw a circle to enable corresponding period. Select date. If you do not select, current setup applies to today only. You can select all week column to apply to the whole week.
Figure 7-42 Figure 7-43 Please refer to the following sheet for detailed information. Parameter Function Event Type There are three types: Motion detection/video loss/Camera Masking. Channel Select channel name from the dropdown list. Enable You need to draw a circle to enable motion detection function. Sensitivity There are six levels. The sixth level has the highest sensitivity.
Parameter Function Region z There are six levels. The sixth level has the highest sensitivity. z Region: If you select motion detection type, you can click this button to set motion detection zone. The interface is shown as in Figure 743. There are PAL 22X18/NTSC 22X15 zones. Right click mouse you can go to full-screen display mode. Do remember clicking OK button to save your motion detection zone setup. z Motion detection function becomes activated in the specified periods.
Parameter Function Copy It is a shortcut menu button. You can copy current channel setup to one or more (all) channels. Save You can click save button after you complete setup for one channel, or you can complete the whole setups and then click save button. Refresh Click this button to get device latest configuration information. 7.3.2.8 PTZ PTZ interface is shown as in Figure 7-44. Please note, before operation please make sure you have set speed dome address.
Parameter Function Parity Default setup is none. Please set according to the speed dome dial switch setup. Save You can click save button after you complete setup for one channel, or you can complete the whole setups and then click save button. Refresh Click this button to get device latest configuration information. 7.3.2.9 Default & Backup Default: Restore factory default setup. You can select corresponding items.
Please note, if you want to use local storage function, your storage device need to support current function. Please select the storage device first and then you can see the items on your right become valid. You can check the corresponding item here. See Figure 7-46. Figure 7-46 Please refer to the following sheet for detailed information. Parameter Function Format Clear data in the disk. Read/write Set current disk as read/write Read only Set current disk as read.
Figure 7-47 Important The alarm output port should not be connected to high power load directly (It shall be less than 1A) to avoid high current which may result in relay damage. Please use the co contactor to realize the connection between the alarm output port and the load. Please refer to the following sheet for detailed information. Parameter Function Alarm output There are six output channels (Multiple choices).
Figure 7-48 Please refer to the following sheet for detailed information. Parameter Function System enables auto record function as you set in record schedule setup. Enable corresponding channel to record no matter what period Manual applied in the record setup. Stop current channel record no matter what period applied in the Stop record setup. Operation here is the same to chapter 4.2 Manual Record. Please refer to chapter 4.2 for detailed information. Auto 7.3.3.
Figure 7-49 7.3.3.5 Auto Maintenance Here you can select auto reboot and auto delete old files interval from the dropdown list. See Figure 7-50.
7.3.3.6 Snapshot Snapshot interface is shown as in Figure 7-51. For 4 HDDs series: The 1st /9th /17th /25th -channel support D1/CIF/QCIF resolution. The 2nd to 8th –channel, the10th to 16th –channel, the 18th to 24th-channel and the 26th to 32nd-channel support CIF/QCIF. For 8 HDDs series: The 1st to the 16th -channel support D1/HD1/BCIF/CIF/QCIF. Figure 7-51 Please refer to the following sheet for detailed information. Parameter Function Channel It is the monitor channel.
Figure 7-52 Please refer to the following sheet for detailed information. Parameter Function Event Type z The abnormal events include: no disk, no space, disk error, net error. z You need to draw a circle to enable this function. Normal Out The corresponding alarm activation output channel when alarm occurs, There are six channels. Latch The alarm output can delay for the specified time after alarm stops. Then system disables alarm and corresponding activation output.
Figure 7-53 7.3.4 Additional Function 7.3.4.1 Preferred DNS Here you can set server or local operator DNS address. See Figure 7-54. Figure 7-54 7.3.4.2 Card Overlay Tit is the same with the card overlay function (chapter 5.5.9). It is mainly for financial areas to Sniffer, information parse and character overlay. The ATM/POS interface is shown as in Figure 7-55.
Source IP refers to host IP address that sends out information (usually it is the device host connected to the DVR.) Destination IP refers to other systems that receive information. There are total four groups IP. The record channel applies to one group (optional) only. Six frame ID groups verification can guarantee information validity and legal. The start position, length and data can be set according to your protocol and data packet. There are total four fields. Figure 7-55 7.3.4.
Please refer to the following sheet for detailed information. Parameter Function Enable Enable auto register function. No. Device management server number. IP Device management server IP address. Port Server port number. Device ID Device ID in the device management server. 7.4 Search Click search button, you can see an interface is shown as in Figure 7-57. The record type includes the general record, alarm record, motion detect record, local record, picture, card number record.
Figure 7-58 Now you can see system begins download and the download button becomes stop button. You can click it to terminate current operation. At the bottom of the interface, there is a process bar for your reference. See Figure 7-59. Figure 7-59 When download completed, you can see a dialogue box shown as in Figure 7-60. Please click OK to exit.
Figure 7-60 Please refer to the following sheet for detailed information. Type Parameter Function Type Record Search general record, alarm record and motion detection record. Alarm Search alarm record. Motion Search motion detection record. Detection Local Search local record. Snapshot Search snapshot file. Card Search card file. Item Begin Set the file start time. You can select from the dropdown time list. End time Set the file end time.
2: Pause 3: Stop 4: Slow play 5: Fast play Playback device IP address and channel number. Playback control bar Figure 7-61 7.5 Alarm Click alarm function, you can see an interface is shown as in Figure 7-62. Here you can set device alarm type and alarm sound setup.
Figure 7-62 Please refer to the following sheet for detailed information. Please make sure current device can upload the alarm. Type Parameter Function Alarm Video loss System alarms when video loss occurs. Type Motion detection System alarms when motion detection alarm occurs, Disk full System alarms when disk is full. Disk error System alarms when disk error occurs. Camera System alarms when camera is viciously masking. masking Encode alarm System alarms when peripheral device alarms.
Figure 7-63 7.7 Log out Click log out button, system goes back to log in interface. See Figure 7-64. You need to input user name and password to login again. Figure 7-64 7.8 Un-install Web Control You can use web un-install tool “uninstall web.bat” to un-install web control. Please note, before you un-installation, please close all web pages, otherwise the uninstallation might result in error.
8 Professional Surveillance System Besides Web, you can use our Professional Surveillance Software (PSS) to login the device. For detailed information, please refer to PSS user’s manual.
9 FAQ 1. DVR can not boot up properly. There are following possibilities: z Input power is not correct. z Power connection is not correct. z Power switch button is damaged. z Program upgrade is wrong. z HDD malfunction or something wrong with HDD ribbon. z Seagate DB35.1,DB35.2,SV35 or Maxtor 17-g has compatibility problem. Please upgrade to the latest version to solve this problem. z Front panel error. z Main board is damaged. 2. DVR often automatically shuts down or stops running.
z DVR color or brightness setup is not correct. 6. Can not search local records. There are following possibilities: z HDD ribbon is damaged. z HDD is broken. z Upgraded program is not compatible. z The recorded file has been overwritten. z Record function has been disabled. 7. Video is distorted when searching local records. There are following possibilities: z Video quality setup is too low. z Program read error, bit data is too small. There is mosaic in the full screen.
z PTZ decoder and DVR address is not compatible. z When there are several decoders, please add 120 Ohm between the PTZ decoder A/B cables furthest end to delete the reverberation or impedance matching. Otherwise the PTZ control is not stable. z The distance is too far. 12. Motion detection function does not work. There are following possibilities: z Period setup is not correct. z Motion detection zone setup is not correct. z Sensitivity is too low. z For some versions, there is hardware limit.
z System uses too much CPU resources. Please stop record first and then begin backup. z Data amount exceeds backup device capacity. It may result in burner error. z Backup device is not compatible. z Backup device is damaged. 17. Keyboard can not control DVR. There are following possibilities: z DVR serial port setup is not correct z Address is not correct z When there are several switchers, power supply is not enough. z Transmission distance is too far. 18.
z There is no DivX503Bundle.exe control when you play the file transformed to AVI via media player. z No DivX503Bundle.exe or ffdshow-2004 1012 .exe in Windows XP OS. 23. Forget local menu operation password or network password Please contact your local service engineer or our sales person for help. We can guide you to solve this problem.
Appendix A HDD Capacity Calculation Calculate total capacity needed by each DVR according to video recording (video recording type and video file storage time). Step 1: According to Formula (1) to calculate storage capacity qi that is the capacity of each channel needed for each hour, unit Mbyte.
Appendix B Compatible Backup Device List Compatible USB drive list NOTE: Please upgrade the DVR firmware to latest version to ensure the accuracy of the table below. If you use the USB drive, please confirm the format FAT or FAT32.
Compatible SD Card List Please refer to the following sheet for compatible SD card brand. Brand Standard Capacity Transcend SDHC6 16GB Kingston SDHC4 4GB Kingston SD 2GB Kingston SD 1GB Sandisk SDHC2 8GB Sandisk SD 1GB Card type SD SD SD SD Micro-SD Micro-SD Compatible Portable HDD List Please refer to the following sheet for compatible portable HDD brand. Brand Model Capacity YDStar YDstar HDD box 40G Netac Netac 80G Iomega RPHD-CG" Iomega 250GB RNAJ50U287 WD Elements WCAVY1205901 1.
Seagate Barracuda.10 ST3500630AS 500G SATA Seagate Barracuda.10 ST3400620AS 400G SATA Seagate Barracuda.10 ST3320620AS 320G SATA Seagate Barracuda.10 ST3250620AS 250G SATA Seagate Barracuda.10 ST3250820AS 250G SATA Seagate Barracuda.10 ST3160815AS 160G SATA Seagate Barracuda.10 ST380815AS 80G SATA Seagate Barracuda.9 ST3160811AS2 160G SATA Seagate Barracuda.9 ST3120811AS2 120G SATA Seagate Barracuda.9 ST380811AS2 80 SATA Seagate Barracuda.
Samsung / HA101UJ/CE 1T SATA 163
APPENDIX C Compatible CD/DVD Device List NOTE: Please upgrade the DVR firmware to latest version to ensure the accuracy of the table below. And you can use the USB cable with the model recommended to set USB burner.
Appendix D Compatible Displayer List Please refer to the following sheet for the compatible device for the standard 1U series product.
SANGSUNG(LCD) T240 24-inch DELL(LCD) E170Sc 17-inch BENQ(LCD) G2219HD 19-inch LG(LCD) W194ST 19-inch 166
Appendix E Compatible Switcher List Please refer to the following sheet form compatible switcher list.
Appendix F Compatible Wireless Mouse List Please refer to the following sheet for compatible SD card brand.
Appendix G Earthing 1. What is the surge? Surge is a short current or voltage change during a very short time. In the circuit, it lasts for microsecond. In a 220V circuit, the 5KV or 10KV voltage change during a very short time (about microseconds) can be called a surge. The surge comes from two ways: external surge and internal surge. z The external surge: The external surge mainly comes from the thunder lightning. Or it comes from the voltage change during the on/off operation in the electric power cable.
work. The signal lightning arrester has many specifications, and widely used in many devices such as telephone, network, analog communication, digital communication, cable TV and satellite antenna. For all the input port, especially those from the outdoor, you need to install the signal lightning arrester. z Antenna feed cable lightning arrester: It is suitable for antenna system of the transmitter or the device system to receive the wireless signal. It uses the serial connection too.
Mixed ground: The mix ground consists of the feature of the one-point ground and multiple-point ground. For example, the power in the system needs to use the one-point ground mode while the radio frequency signal requires the multiple-point ground. So, you can use the following figure to earth. For the direct current (DC), the capacitance is open circuit and the circuit is one-point ground. For the radio frequency signal, the capacitance is conducive and the circuit adopts multiple-point ground.
z z The monitor system usually can adopt the one-point ground. Please connect the ground end of 3-pin socket in the monitor system to the ground port of the system (protection ground cable) 4. The shortcut way to check the electric system using the digital multimeter For 220V AC socket, from the top to the bottom, E (ground cable), N (neutral cable), L(live cable). Please refer to the following figure.
For L (live cable) Turn the digital multimeter to 750V AC, use your one hand to hold the metal end, and then the other hand insert the pen to the L port of the socket. See the following figure. If the multimeter shows 120, then you can see current live cable connection is standard. If the value is less than 60, then you can see current live cable connection is not proper or it is not the live cable at all.
Appendix H Toxic or Hazardous Materials or Elements Component Name Toxic or Hazardous Materials or Elements Pb Hg Cd Cr VI PBB PBDE ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ Circuit Board ○ ○ ○ ○ ○ ○ Fastener Wire and Cable/Ac Adapter Packing Material Accessories ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ ○ Sheet Metal(Case) Plastic Parts (Panel) Note O: Indicates that the concentration of the hazardous substance in all homogeneous materials in the parts is below the rel