Installation guide
DVTel CF-4221-00 Fixed IP Camera User & Installation Guide
11
c.) Loosen the screws or unlatch the camera housing lid, open
the housing and loosen the plastic cable glands (cable fittings)
d.) Thread the cables through the cable glands into the camera housing.
e.) Attach the camera housing to the wall bracket (arm) using the provided screws and
wrench.
f.) Remove the housing plate (base for camera) and using the provided camera mount
screw, thread the screw through the plate into the camera’s bottom mounting socket.
g.) Put the camera mounted on the base plate back in the housing.
(We will adjust forward positioning when we adjust the lens.)
Caution: Follow the electrical and safety codes as applicable for where the camera
is being installed.
h.) For housings with internal blowers and heaters: Connect the wiring to the camera
housing terminals (power input) according to the manufacturer’s instructions for
heaters (heater output) and fans (blower output) that the camera housing features.
Connect any earthen ground to the camera housing earthen ground connection.
2.) Connect the cables and wiring to the camera:
a.) Plug the CAT5 cable into the camera Ethernet port and if needed wire a properly rate
power supply into the power terminal-block plug and insert it into the power terminal
block.
b.) If applicable, wire the Alarm In, Alarm Out, Audio In and Audio Out terminal blocks to
external devices.
c.) If not already connected, connect the other end of the CAT5 cable to the network.
Cable Gland