Installation manual
trk1 Installation Manual 
 12     
Relay Output Specifications 
  Maximum current 1A @ 24VDC 
Relay Contacts Schematic 
Figure 10: Relay Contacts 
  NC: Terminal for connecting one of a pair of wires that leads to an external device on a circuit 
configured for NORMALLY CLOSED 
  C: Terminal for connecting the second of a pair of wires for the COMMON lead of an external 
device regardless of whether the device is operated in a NORMALLY OPEN or NORMALLY CLOSED 
configuration 
  NO: Terminal for connecting one of a pair of wires that leads to an external device on a circuit 
configured for NORMALLY OPEN 
A relay output terminal has two options for connecting a device: 
  Option 1: NORMALLY CLOSED configuration 
  Option 2: NORMALLY OPEN configuration 
The output supports opto-isolated signal for a single external device. Signals can be sent as continuous 
(ON/OFF) or single pulse of predefined duration. 
To connect a device controller to a relay output of the unit 
1.  Connect the leads from the external device controller to the respective terminal points on the 
Spring Clamp Terminal Block according to your requirements (NORMALLY OPEN or NORMALLY 
CLOSED configuration). See Connecting Leads to a Spring Clamp Terminal Block (page 18). The 
three terminal points for the relay output are located on the top right of the terminal block. See 
Figure 3: trk1 Power Connection Panel. 
2.  Connect the terminal block to the external devices connector on the power connection panel of 
the unit. See Figure 3: trk1 Power Connection Panel. 
3.  Connect the other end of the cable to the external controller, which receives the signal from 
the unit and controls/powers the external device. 
Warning: 
The signal from the relay output of the unit must be used as an indicator and not for direct 
control of a device. 
Caution:  
To prevent damage to the unit, do not exceed the voltage and current ratings for the relay 
terminals. 