DVTEL INC. 65 Challenger Road Ridgefield Park, NJ 07660 trk-101-P PTZ Tracker Installation Manual The contents of this manual may not The contents of this guide may be reproduced or reprinted in whole not be reproduced or reprinted or in part without the express written in whole or in part without the permission of DVTEL, INC. express written permission of DVTEL, INC.
Table of Contents Table of Contents 1. Document Information.............................................................................................. iii 2. Introduction .............................................................................................................. 1 2.1 Items Included in the Package .................................................................................. 2 2.2 Hardware Description ................................................................................
trk-101-P Installation Manual List of Figures Figure 1: trk-101-P Unit .............................................................................................................. 1 Figure 2: trk-101-P Unit Connectivity.......................................................................................... 1 Figure 3: trk-101-P Power Connection Panel ............................................................................. 2 Figure 4: trk-101-P Video Connection Panel ...............................
Document Information 1. Document Information Document Conventions Conventions relatives au document WARNING and CAUTION notes are distributed throughout this document, whenever applicable, to alert you of potentially hazardous situations. These may be hazards associated with a task or a procedure you are carrying out or are about to carry out.
trk-101-P Installation Manual Document Scope and Purpose The purpose of this document is to provide instructions and installation procedures for physically connecting the trk-101-P unit. After completing the physical installation, additional setup and configurations are required before video analysis and detection can commence. For information on the unit setup and configuration, refer to the HTML Edition Units User’s Guide.
Document Information Disclaimer Avis de non-responsabilité Users of DVTEL products accept full responsibility for ensuring the suitability and considering the role of the product detection capabilities and their limitation as they apply to their unique site requirements. Il incombe aux utilisateurs des produits DVTEL de vérifier que ces produits sont adaptés et d'étudier le rôle des capacités et limites de détection du produit appliqués aux exigences uniques de leur site. DVTEL, Inc.
trk-101-P Installation Manual Warning: 1. The unit’s cover is an essential part of the product. Do not open or remove it. 2. Never operate the unit without the cover in place. Operating the unit without the cover poses a risk of fire and shock hazards. 3. Do not disassemble the unit or remove screws. There are no user serviceable parts inside the unit. 4. Only qualified trained personnel should service and repair this equipment. 5.
Document Information Electrical Safety Notice and Warnings Warning: 1. Read the installation instructions before you connect the unit to a power source. 2. Electrical safety should always be observed. All electrical connections must be performed by a certified electrician. 3. Use the supplied power supply and protect against static electricity, ground faults and power surges. 4. The unit uses a three-wire power cord to make sure that the product is properly grounded when in use. This is a safety feature.
trk-101-P Installation Manual Avis et avertissements relatifs à la sécurité électrique Avertissement: 1. Lisez les instructions d'installation avant de brancher l'unité à une source d'alimentation électrique. 2. Les consignes de sécurité électrique doivent toujours être respectées. Toutes les connexions électriques doivent être effectuées par un électricien qualifié. 3. Utilisez l'alimentation fournie, et protégez l'unité contre l'électricité statique, les défauts de mise à la terre et les surtensions. 4.
Document Information Minimizing EMI and RFI Minimisation des IEM et des IRF When wires run for a significant distance in an electromagnetic field, electromagnetic interference (EMI) can occur. Strong EMI (e.g. lightning or radio transmitters) can destroy the units and can pose an electrical hazard by conducting power through lines and into the system. Poor quality or worn wiring can result in radio frequency interference (RFI). To minimize the effects of EMI and RFI, consult your reseller.
Introduction 2. Introduction The trk-101-P PTZ Tracker is a single-channel, self-contained H.264 IP video analytic encoder that is designed to control and monitor the video input from an analog PTZ camera. Once a moving object has been detected, the unit controls and moves the PTZ camera to autonomously track and zoom in on the threat.
trk-101-P Installation Manual 2.1 Items Included in the Package The unit package contains the following items: QTY Description 1 trk-101-P PTZ Tracker 1 Mounting bracket 1 Set of spring clamp terminal blocks 1 Documentation and utilities CD Related Documentation: HTML Edition Units User’s Guide ioi Product Selection Matrix trk-101 and trk-101-P Quick Install Guide DNA 2.0 User Manual 2.2 Hardware Description This section describes the connection panels of the unit. 2.2.
Introduction Item Description RESET Button For setting the unit factory defaults, setting Technician mode, or resetting the unit. LEDs The LEDs indicates several status conditions: Off: The unit is resetting. Flashing green (300ms intervals): The firmware is booting. Flashing green (one second intervals): The firmware has booted successfully, the encoder is connected to the network, and unit is operating normally. Steady red: Failure in the first phase of the boot.
trk-101-P Installation Manual 2.2.2 Video Connection Panel The following is a description of the video connection panel of the unit. Figure 4: trk-101-P Video Connection Panel The video connection panel of the unit includes the following items: Item Description VIDEO OUT (BNC) Output interface that provides the analog video signal after analysis and includes detection overlays and additional On-Screen Display (OSD) information.
Installing and Connecting the Unit 3. Installing and Connecting the Unit This section describes how to install and connect the unit and includes the following sections: Installing the Unit (page 5) Connecting the Unit (page 7) Resetting the Unit (page 14) Note: After connecting the unit, proceed to configure the unit as described in the HTML Edition Units User’s Guide. 3.1 Installing the Unit The unit can be installed and mounted next to the camera (inside the camera enclosure).
trk-101-P Installation Manual To assemble units in a rack mount panel: 1. Remove the nut and washer from each of the two video connectors on the video connection panel of the unit. Figure 5: trk-101-P with Nuts Removed 2. Attach each unit to the rear side of the rack mount panel by inserting it through the holes as shown in Figure 6. Figure 6: Inserting Units into Rack Mount Panel 3.
Installing and Connecting the Unit 3.
trk-101-P Installation Manual Warning: 1. To prevent bodily injury or damage to the unit, use only properly rated and approved power supplies and/or AC adaptors. 2. Make sure that the power supply matches the required specifications. Electrical safety should always be observed. Avertissement: 1. Pour prévenir toute blessure corporelle ou tout endommagement de l'unité, n'utilisez que des alimentations et/ou des adaptateurs secteur correctement classifiés et approuvés. 2.
Installing and Connecting the Unit To change the unit’s IP address 1. Insert the CD included in the package in your computer’s disk drive. Note: The PC and the unit must be physically connected on the same subnet. 2. Run the dna.exe file by clicking the displayed in the window. 3. Select the unit by right-clicking on it. icon. The DNA application opens and the device is Figure 7: DNA Discovery Window 4. If there are devices located on a separate VLAN, click add them manually. 5.
trk-101-P Installation Manual 6. For each unit, do one of the following: If your network uses a DHCP server: i. Select Use DHCP. ii. Click Update. A new IP address is automatically assigned to the selected device(s) by the network DHCP server. If your network uses Latitude: i. Set a static IP address. ii. Do not select the Use DHCP checkbox. iii. In the IP Address, Gateway, and Mask, enter the respective LAN/VLAN (optional DNS) values. Figure 9: DNA Assign IP – Static IP Dialog Box iv.
Installing and Connecting the Unit 3.2.4 Connecting the Video Source (Camera) to the Unit The unit is designed to accept a composite video signal (1Vp-p) from an analog PTZ camera. Video connections should use a 75Ω cable and should not be longer than 30 meters (98 feet). To connect the video source to the unit 1. Securely connect the video cable BNC connector to the analog video output of the camera or video source. 2.
trk-101-P Installation Manual 3.2.5 Configuring PTZ Camera Settings on the Encoder PTZ camera settings are configured in the Setup > Camera > Type & Model screen in the web interface. Figure 12: Camera > Type & Model Screen To configure PTZ camera settings on the encoder 1. In the Camera Type area, select Pan/Tilt/Zoom (PTZ). 2. Check Enable Re-arm. 3. From the Re-arm Duration drop-down list, select the number of seconds until the unit automatically rearms itself after being operated manually. 4.
Installing and Connecting the Unit To connect the unit analog video output to an analog device Using video coax 75Ω cable with BNC connectors, connect the VIDEO OUT of the ioimage unit to the analog device Video Input (for example, the VIDEO IN of a monitor or DVR). Note: Make sure the ioimage unit and the external analog equipment support the same video standard (PAL/NTSC). 3.2.
trk-101-P Installation Manual Caution: To prevent damage to the unit, do not exceed the voltage and current ratings for the relay terminals. Attention: Pour prévenir tout endommagement de l'unité, ne dépassez pas les valeurs de courant et de tension pour les terminaux relais. Relay Output Specifications Maximum current 1A @ 30VDC Relay Contacts Schematics Figure 13: Relay Contacts Schematic The input supports opto-isolated signal for a single external device.
Installing and Connecting the Unit 3.3.2 Reset by Removing the Power Supply The unit can be reset by turning off the power and then turning it on again. To reset a unit by removing the power supply 1. Turn off or disconnect the power to the unit. 2. Turn on or reconnect the power to the unit. The unit restarts with the last settings.
trk-101-P Installation Manual Appendix The appendix contains the following sections: 16 Technical Specifications (page 17) Connecting Leads to a Spring Clamp Terminal Block (page 19) Troubleshooting (page 20) NO to NC Relay Configuration (page 22)
Appendix A.1. Technical Specifications Following are the trk-101-P technical specifications: Video Input Channels Number of Intelligent Video Analysis Channels 1 Analog Video Output TV Standard Composite 1Vp-p (PAL or NTSC) Physical Connector 1 x BNC 75Ω Digital Encoding IP Video Streaming H.264, MPEG 4 SP, and MJPEG Frame Rate (H.
trk-101-P Installation Manual Physical Dimensions Dimensions (mm) 68.5 x 36 x 118 mm (W x H x D) Dimensions (in.) 2.7 x 1.42 x 4.62” (W x H x D) Environmental Specifications Operating Temperature 0° to 60°C (32° to 140°F) Operating Humidity 5% to 95% (non-condensing) Certifications 18 Safety UL 60950-1:2007; IEC 60950-1:2005 (Ed. 2) + A1:2009 + A2:2013; EN 60950-1:2006 (Ed. 2) + A11:2009 + A1: 2010 + A12:2011 + A2:2013; CAN/CSA-22.2 No.
Appendix A.2. Connecting Leads to a Spring Clamp Terminal Block The unit is delivered with two terminal block connectors. The connectors enable you to connect wires for either the Relay Output or Alarm Input and then connect them to the unit. Figure 14: Spring Clamp Terminal Block To connect a wire to the spring clamp terminal block: 1. Strip the insulation form the end of each wire that is to be connected to the terminal block. Approximately 1 cm (2.54”) of wire should be exposed. 2.
trk-101-P Installation Manual A.3. Troubleshooting This section provides useful information and remedies for common situations where problems may be encountered. Problem Possible Solution No network connection Hardware issues: Check that the network is working and the unit is powered on. Check that the network (Ethernet) cable is properly attached to the unit. Confirm that the LED on the Ethernet (RJ45) connector on the power connection panel of the unit is on.
Appendix Problem Bad output video quality Possible Solution Streaming video image is hanging (stopped) Alarm inputs are not working Relay outputs are not working Check the source video signal quality by connecting an analog monitor to the video source. If video quality is acceptable, connect the video source to the unit. Check that the cables are connected securely. This includes junction boxes and amplifier that may be used.
trk-101-P Installation Manual A.4. N/O to N/C Relay Configuration The on-board relay in the trk-101-P provides a single contact which is by default NORMALLY OPEN (N/O), enabling it to be configured to CLOSED upon an alarm condition. This is usually configured with a momentary closure (for example, five seconds), followed by returning to the OPEN condition, to be ready for the next alarm event.
Contacting DVTEL Contacting DVTEL To contact us, write us at info@dvtel.com or contact your local office. CORPORATE HEADQUARTERS DVTEL, Inc. 65 Challenger Road Ridgefield Park, NJ 07660 USA Tel: 201.368.9700 Fax: 201.368.2615 Order Fax: 201.712.0343 info@dvtel.com ASIA PACIFIC REGION DVTEL 111 North Bridge Road, #27-01 Peninsula Plaza Singapore 079098 Tel: +65 6389 1815 Fax: +65 6491 5660 info.apac@dvtel.