Instalation & Assembly
WAC Lighting
www.waclighting.com
Phone (800) 526.2588 • Fax (800) 526.2585
Headquarters/Eastern Distribution Center
44 Harbor Park Drive • Port Washington, NY 11050
Phone (516) 515.5000 • Fax (516) 515.5050
Western Distribution Center
1750 Archibald Ave • Ontario, CA 91761
Phone (800) 526.2588 • Fax (800) 526.2585
WAC Lighting retains the right to modify the design of our products at any time as part of the company's continuous improvement program. JANUARY, 2017
INSTALLATION INSTRUCTION
Dice - dweLED
FM-4006, FM-4009
PREPARATION
1. Shut o the power at the circuit breaker and remove existing xture, including the crossbar.
2. Carefully unpack your new xture and lay out all the parts on a clear area. Be careful not to lose any small parts necessary for installation.
CONNECTING THE WIRES (Fig. 2)
3. Connect the xture wires with supply wires as shown in Fig. 2, making sure all wire connector(A1) are secured. If your outlet box has a
green or bare copper ground wire, connect the xture’s ground wire to it. Otherwise, connect the xture’s ground wire directly to the
mounting plate using the green screw provided. After all wires are connected, tuck them carefully inside the junction box.
MOUNTING THE FIXTURE (Fig. 1)
4. Secure mounting plate to the junction Box using the junction box screws (B1) .
The side of the mounting plate marked “GND” must face out.
5. Place the canopy over the mounting plate and secure with screws.
6. Hold the glass shade down while tightening the securing screws with the allen
wrench (D1) to make sure the screws (C1) engage within the metal slot on the
glass shade.
7. Don’t turn the screws fully inserted. Leave about 2 to 3 mm exposed length
outside the metal base. This will allow the glass shade to be positioned more
centered with respect to the metal base.
8. After securing down the screws, check the make sure the glass shade is fas-
tened securely within the slots provided.
FIG.1
Fixture Wires
Black or
Smooth
Fixture Wires
White or
Ribbed
Fixture Wires
Bare wire
(Ground)
House Wires
Black
(Hot)
House Wires
White
(Neutral)
House Wires
Green or Bare Copper
(Ground)
Fig.2 Wiring
G0
Junction Box
Connectors
Mounting Plate
Black Fixture Wire
Canopy
Screw
Glass
Allen Screw
Allen Wrench
Junction Box Screw
White Fixture Wire
Ground Wire
B1
D1
C1
A1
Don't turn the screws fully
inserted. Leave about 2 to 3
mm exposed length outside
the metal base. This will allow
the glass shade to be more
positioned more centered with
respect to the metal base.
FM-4009:
Set screw supposed to land
in the centre of groove/metal
shim. Make sure the set screw
is in the groove.