User manual

PROFESIONAL, CREDITABLE, SUCCESSFULL DWIN DGUS v2.0 Specification
Beijing DWIN Technology Co., Ltd. - 8 - www.dwin.com.cn/en
expanded reference memory access when reading and writing real-time (mS level) were low required.
The data memory spaces can only by word to read and write, with the corresponding address space 0x0000-0x6FFF.
The data memory space accessed by Command 0x82/0x83
Curve data buffer
In order to simplify the display of real-time curve, DWIN DGUS v2.0 designed a curve data buffer that is used to
cache the data of the users curve, which will not occupy that data space while 8 units of curves are working at the
same time.
Curve data buffer can only by word to read. Each data on the point of the curve is predicted by a 2-Byte unsigned
integer.
Curve data buffer can be accessed by Command 0x84 (only write).
1.4 Software upgrade procedure
Tools:
A DC regulated power supply that adjust the output voltage to the appropriate value;
A serial port cable;
A computer which has a hardware serial port and serial debugging assistant SSCOM3.2 software or any similar
software under different OS.
The Steps instruction of Update:
a. Turn off the DWIN Module and make sure serial port is connected to the computer’s COM port.(eg:com1)
b. Open the SSCOM3.2 software and click "Open File" to select DGUS_V2.0.BIN;
c. Write "DWIN_M600_BOOT!" in data input column and set send-eve interval to 10ms/Time;
d. Select "Send New" and "Send-eve", then power DWIN module again.
e. The serial port will receive "Erase ......”. If no response, please check the connection.
f. It will receive "Please Tx File!" after one second, then hook off "Send New" and click "Send File".
g. Wait another 3 to 10 seconds. If the serial port receives "***************END***************", it means the
download is finished.
h. Restart the module. Update finished.