5.2.2 Text Display (0x11)
Address
Definition
Data Length
Description
0x00
0x5A11
2
0x02
*SP
2
Variable description pointer, 0xFFFF indicates it loaded by config. file
0x04
0x000D
2
0x06
0x00
*VP
2
Text pointer
0x08
0x01
X,Y
4
Starting display position. The coordinate is upper left point of
displayed string.
0x0C
0x03
Color
2
Text color
0x0E
0x04
Xs Ys Xe Ye
8
Text box
0x16
0x08
Text_length
2
Amount of displaying bytes. It will be shown unless 0xFFFF or texting
towards the end of the textbox.
0x18
0x09:H
Font0_ID
1
Font location of the ASCII in coding 0x01-0x04
0x19
0x09:L
Font1_ID
1
Font location of coding 0x00&0x05 and non-ASCII in coding
0x01-0x04
0x1A
0x0A:H
Font_X_Dots
1
Dot matrix of the font X-Direction(0x01-0x04 mode,ASCII character
X is accounted by X/2 )
0x1B
0x0A:L
Font_Y_Dots
1
Dot matrix of the font Y-Direction
0x1C
0x0B:H
Encode_Mode
1
Coding method:
0=8bit coding 1=GB2312 2=GBK 3=BIG5 4=SJIS 5=UNICODE
0x1D
0x0B:L
HOR_Dis
1
Character horizontal interval
0x1E
0x0C:H
VER_Dis
1
Character vertical interval
Note: dot matrix of Y-Direction should be even number when text displayed.