DLI-P Data Logger Manual P.O. Box 373 l 102 Indiana Hwy. 212, Michigan City, IN 46361 USA Phone: 219.879.8000 l Fax: 219.872.9057 www.dwyer-inst.com l info@dwyer-inst.
Table of Contents Data Logger Manual Section 1: Device Safety............................................................................3 1.1 Model information ...................................................................3 1.2 Specifications ...........................................................................3 1.3 Warranty ..................................................................................5 Section 2: Device Overview ..............................................................
Dwyer DLI-P 6.7 Channel Statistics: ..................................................................21 6.8 Type Statistics: ........................................................................21 6.9 Statistics Information Screen: ..................................................22 6.10 Unit Selection Menu: ............................................................22 6.11 Device Configuration Menu:.................................................23 6.12 Adjust Visibility: ...........................
Data Logger Manual Section 1: Device Safety CAUTION: DEVICE MUST BE USED ONLY IN A MANNER CONSISTENT WITH THIS MANUAL. NOTICE: WHEN 230VAC SUPPLY USED, DWYER SPECIFIES USE OF AC SUPPLY PART # T35-9-100R-3 MANUFACTURED BY ENG ELECTRIC. THIS SUPPLY IS AVAILABLE FROM DWYER. 1.1 Model information • Model: DLI-P • Description: Measure & record temperature, humidity, atmospheric pressure with LCD display • Manufactured in the USA 1.
Dwyer DLI-P Start/Stop Time: Software programmable start time and date, up to six months in advance; programmable stop time Memory: 87,381 readings per channel; 262,143 total readings; software configurable memory wrap Reading Rate: 1 reading every 2 seconds to 1 every 24 hours Calibration: Digital calibration through software Calibration Date: Automatically recorded within device Battery Type: 9V lithium battery included, user replaceable; optional AC adapter, 7-24 VDC Volts, 100mA.
Data Logger Manual 1.3 Warranty Products manufactured by Dwyer Instruments, Inc., are warranted against defective material and workmanship for a period of one year, starting from the date of shipment. In the event that a Dwyer product is found to be defective, Dwyer will repair or replace the product at its sole discretion. Such repair or replacement shall be the sole remedy of this warranty.
Dwyer DLI-P Section 2: Device Overview Pressure Sensor Power Jack Temperature and Humidity Sensor Ventilation Holes LED Lights Communication Jack LCD Display Screen Bleach anodized aluminum enclosure Page 6 Up Key Okay Key Down Key Function Keys Cancel Key
Data Logger Manual Section 3: Important Status Icons 3.1 Battery Status Full Battery Empty Battery Battery status icons indicate the state of charge of the batteries. When the battery empty indicator is displayed, the battery should be replaced. 3.1 Memory Status Memory Empty Memory Full The memory status icons indicate the amount of memory left for data storage. If the DLI-P is in wraparound mode, the memory status icon will indicate empty. 3.
Dwyer DLI-P 3.2 Delay Start Indicator The delay start icon indicates that a logging operation is scheduled for the future. 3.3 Wait Icons The wait icons indicate that the device is busy. 3.4 Stop Icon Indicates that the DLI-P is not currently taking readings. 3.5 External Power Icon Indicates that the DLI-P is powered by an external source. 3.1 Reset Icon Indicates that the device has been reset.
Data Logger Manual Section 4: Front Panel Overview 4.1 Changing the display units The DLI-P comes with factory default display units of °C for temperature, %RH for humidity, and PSIA for pressure. These units can be easily changed by pressing the F3 button in the main screen and then selecting either F1 for temperature, F2 for humidity or F3 for pressure.
Dwyer DLI-P Large: Up to two channels can be displayed at a time with the option of using the UP and DOWN buttons to scroll to view the third. Button pressing chain: Main Screen -> F4 -> F1 -> F4 -> F2 repeatedly to scroll 4.3 Checking the memory Status A status icon appears on all screens representing memory, but further information including percent memory left and number of readings taken can also be viewed.
Data Logger Manual Section 5: DLI-P Function Reference 5.1 Main Screen The main screen of the DLI-P features a real-time display of most recently measured temperature, humidity, and pressure data. At the bottom of the main screen are tabs corresponding to each of the four function keys. These tabs are used to access the four main function menus of the DLI-P: status, statistics, units, and setup.
Dwyer DLI-P 5.3 Statistics Menu Pressing the F2 key while in the Main Screen brings up the Statistics Menu. From the Statistics Menu, statistics generated from the conditions encountered by the device can be viewed in a variety of different styles including being sorted by channel and by type. The Statistics Menu also displays important statistics information as well as the option to clear the statistics at any time. 5.3.
Data Logger Manual 5.4 Units Pressing the F3 key while viewing the Main Screen will access the Units Selection screen. Here the measurement units can be easily changed. In the Units Selection screen the F1, F2, and F3 function keys correspond to the three channels temperature, humidity, and pressure respectively.
Dwyer DLI-P 5.5.i.b Display Configuration By selecting “MORE” (either by pressing the F4 key on the Adjust Visibility Screen or by pressing the OK button) in the Display section the Display Configuration screen can be viewed. Here LCD screen contrast values can be set as well as the size the channels are displayed on the Main Screen. Contrast To change the LCD screen contrast view while viewing the Display Configuration screen first select the contrast configuration parameter by pressing the F1 key.
Data Logger Manual Display The DLI-P’s LCD screen display has options to be either on continuously or turn off automatically after 5 minutes of inactivity. This option can be changed by first pressing the F1 key to highlight the display parameter configuration tab. Once the tab is highlighted the option can be changed by pressing the F1 key repeatedly or using the UP and DOWN keys to select either “On” or “Auto”. Backlight Like the display, the LCD screen’s backlight also has power saving options.
Dwyer DLI-P changed by the user based on whether a Lithium or Alkaline battery is used in the DLI-P. This can be changed by first pressing the F1 button to highlight the type parameter configuration tab. Once the tab is highlighted, the battery type can be changed by either pressing the F1 key repeatedly or by using the UP and DOWN arrows to select the correct battery type.
Data Logger Manual 5.5.iii.d Device Version Pressing the F4 key while viewing the Maximum or Minimum Device Range screens will display the Device Version screen, containing information such as firmware revision number and communications baud rate. Values on this screen cannot be modified. 5.5.iii.e Firmware Version Firmware details can be viewed by pressing the F2 key while viewing the Device Version screens.
Dwyer DLI-P Section 6: DLI-P Screen Shot Descriptions 6.1 Main Screen: Displays last measured values. F1 = STATUS: goes to status screens F2 = STATS: shows statistics menu F3 = UNITS: goes to unit selection screen F4 = SETUP: shows device configuration menu CANCEL = no function OK = no function UP = scrolls channel readings (only available while using large text) DOWN = scrolls channel readings (only available while using large text) 6.
Data Logger Manual OK = returns to main screen UP = no function DOWN = no function 6.3 Status Screens (Memory Status): Displays information about the device’s memory capabilities including percent of memory available (memory left), number of readings taken so far (readings), max number of readings (max readings), and wrap.
Dwyer DLI-P F3 = TIME: displays time information screen F4 = MORE: displays the second status screen CANCEL = returns to main screen OK = returns to main screen UP = no function DOWN = no function 6.5 ID Parameters Displays information relating to device identity. For all status screens: F1 = ID: no function F3 = MORE: displays the first status screen F4 = EXIT: returns to main screen CANCEL = returns to main screen OK = returns to main screen UP = no function DOWN = no function 6.
Data Logger Manual CANCEL = returns to main screen OK = returns to main screen UP = no function DOWN = no function 6.7 Channel Statistics: Displays statistics (Maximum recorded value, Minimum recorded value, and average recorded value) based on channel (Temperature, Humidity, or Pressure).
Dwyer DLI-P F4 = EXIT: Returns to Statistics Menu CANCEL = returns to Statistics Menu OK = returns to Statistics Menu UP = no function DOWN = no function 6.9 Statistics Information Screen: Displays current statistics information including the number of recorded readings, start date, and start time.
Data Logger Manual F4 = OK: returns to Main Screen Note: unit selection can be changed by pressing the corresponding function key repeatedly or using the UP and DOWN arrows to select appropriate units. CANCEL = returns to main menu without accepting changes OK = accepts changes and returns to main menu 6.11 Device Configuration Menu: Displays options available within the device configuration menu.
Dwyer DLI-P F3 = PRESS: first highlights and then changes the viewing options of the pressure channel F4 = MORE: moves on to Display Configuration screen CANCEL= return to Display Configuration Menu OK = moves on to Display Configuration screen UP = once channel parameter configuration tab is highlighted scrolls through available options DOWN = once channel parameter configuration tab is highlighted scrolls through available options 6.
Data Logger Manual 6.14 Power Modes Screen: Displays information regarding the devices different power modes including the display visibility, backlight options, and LED modes.
Dwyer DLI-P UP = once parameter configuration tab is highlighted scrolls through available options DOWN = once parameter configuration tab is highlighted scrolls through available options 6.16 Power Status Screen: Displays details about power available to the device including the battery type, battery voltage, and external voltage.
Data Logger Manual F3 = CAL: shows Calibration Information screens F4 = MORE: shows further Device Information screens CANCEL = Returns to Device Configuration Menu OK = Returns to Device Configuration Menu UP = No function DOWN = No function 6.18 Device Information Screens (Maximum Device Range): Displays values indicating maximum temperature, pressure and humidity detectable by the DLI-P. 6.19 Device Information Screens (Device Version): Displays device version information.
Dwyer DLI-P 6.20 Device Information Screens (Firmware Version): Displays device firmware version information. F1 = VERS: shows Device Version screen F2 = FIRM: no function F3 = MORE: shows Device Range (Minimum) screen F4 = EXIT: Returns to Device Configuration Menu CANCEL = Returns to Device Configuration Menu OK = Returns to Device Configuration Menu UP = No function DOWN = No function 6.
Data Logger Manual 6.22 Calibration Information Screens (Temperature Calibration): Displays calibration information for temperature channel. F1 = DATE: shows calibration date information F2 = TEMP: no function F3 = HUMID: shows humidity calibration information F4 = MORE: shows further calibration information screens CANCEL = Returns to Device Configuration Menu OK = Returns to Device Configuration Menu UP = No function DOWN = No function 6.
Dwyer DLI-P 6.24 Calibration Information Screens (Pressure Calibration): Displays calibration information for pressure channel. For all Device Information Screens: F1 = PRESS…: no function F3 = MORE: shows further calibration information screens F4 = EXIT: Returns to Device Configuration Menu CANCEL = Returns to Device Configuration Menu OK = Returns to Device Configuration Menu UP = No function DOWN = No function 6.
Data Logger Manual 6.26 Device Reset Screen (Power Interruption): Displayed as notification when power is interrupted during device operation.
Dwyer DLI-P Section 7: Computer Interface: 1. Insert the USB connector of the DL700 into an available USB port. Fully insert male connector of the DL700 interface cable into the female receptacle of the data logger*. *WARNING: Install driver before connecting a device using a USB for the first time. See the Dwyer Data Logger Software manual for further information.
Data Logger Manual Section 8: Wall Mounting Power Supply Cable Slot Page 33
Dwyer DLI-P Section 9: Maintenance BATTERY WARNING Most Dwyer data loggers contain a lithium battery. Do not cut the battery open, incinerate, or recharge. Do not heat lithium batteries above the specified operating temperature.* Dispose of the battery in accordance with local regulations. *See the individual specification sheets at www.dwyer-inst.com. The DLI-P does not have any user-serviceable parts except the battery which should be replaced periodically.
Data Logger Manual Terms and Conditions All products furnished by Dwyer Instruments, Inc. (“Seller”) shall be in accordance with the following terms and conditions unless otherwise stated in writing: These Terms and Conditions (“Terms and Conditions”) govern (a) all sales quotations and sales of components, equipment, parts, and other products (“Product”) from, and (b) all service proposals and provisions of services by Seller to the buyer of the Products (“Buyer”).
Dwyer DLI-P WHETHER EXPRESSED, IMPLIED OR STATUTORY, INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, NONINFRINGEMENT OR ACCURACY, ADEQUACY OR COMPLETENESS OF DATA MEASUREMENT, WITH RESPECT TO ANY OF THE SELLER MANUFACTURED PRODUCTS, CONSUMABLES OR SOFTWARE, OR ANY OF THE SELLER PROVIDED SERVICES. Any drawings submitted with the Products are only to show the general style, arrangement, and approximate dimensions of the Products. B.
DLI-P Data Logger Manual P.O. Box 373 l 102 Indiana Hwy. 212, Michigan City, IN 46361 USA Phone: 219.879.8000 l Fax: 219.872.9057 www.dwyer-inst.com l info@dwyer-inst.