DLI2 Data Logger Manual P.O. Box 373 l 102 Indiana Hwy. 212, Michigan City, IN 46361 USA Phone: 219.879.8000 l Fax: 219.872.9057 www.dwyer-inst.com l info@dwyer-inst.
Table of Contents Data Logger Manual Section 1: Device Safety............................................................................3 1.1 Model information ...................................................................3 1.2 Specifications ...........................................................................3 1.3 Warranty ..................................................................................5 Section 2: Device Overview ..............................................................
Dwyer DLI2 6.7 Channel Statistics: ..................................................................21 6.8 Type Statistics: ........................................................................21 6.9 Statistics Information Screen: ..................................................22 6.10 Unit Selection Menu: ............................................................22 6.11 Device Configuration Menu:.................................................23 6.12 Adjust Visibility: ............................
Data Logger Manual Section 1: Device Safety CAUTION: DEVICE MUST BE USED ONLY IN A MANNER CONSISTENT WITH THIS MANUAL. NOTICE: WHEN 230VAC SUPPLY USED, DWYER SPECIFIES USE OF AC SUPPLY PART # T35-9-100R-3 MANUFACTURED BY ENG ELECTRIC. THIS SUPPLY IS AVAILABLE FROM DWYER. 1.1 Model information • Model: DLI2 • Description: Measure and record pressure with LCD display featuring real-time on screen graphing capabilities and a 1/4” NPT fitting. • Manufactured in the USA 1.
Dwyer DLI2 Calibration Date: Automatically recorded within device Battery Type: 6 alkaline AA batteries, user replaceable; optional AC adapter, 7-24 VDC, 100mA. For 230 VAC operation use AC supply T35-9-100 R-3 made by ENG Electric. Battery Life: 60 days typical with continuous screen use; 360 days with display off.
Data Logger Manual 1.3 Warranty Products manufactured by Dwyer Instruments, Inc., are warranted against defective material and workmanship for a period of one year, starting from the date of shipment. In the event that a Dwyer product is found to be defective, Dwyer will repair or replace the product at its sole discretion. Such repair or replacement shall be the sole remedy of this warranty.
Dwyer DLI2 Section 2: Device Overview Pressure Sensor Power Jack LED Indicators Communication Jack LCD Screen Up Key Okay Key Black anodized aluminum enclosure Down Key Function Keys Page 6 Cancel Key
Data Logger Manual Section 3: Important Status Icons 3.1 Battery Status Full Battery Empty Battery Battery status icons indicate the state of charge of the batteries. When the battery empty indicator is displayed, the battery should be replaced. 3.2 Memory Status Memory Empty Memory Full The memory status icons indicate the amount of memory left for data storage. If the DLI2 is in wraparound mode, the memory status icon will always indicate empty. 3.
Dwyer DLI2 3.4 Delay Start Indicator The delay start icon indicates that a logging operation is scheduled for the future. 3.5 Wait Icon The wait icon indicates that the device is busy. 3.6 Stop Icon Indicates that the DLI2 is not currently taking readings. 3.7 External Power Icon Indicates that the DLI2 is powered by an external source. 3.8 Reset Icon Indicates that the device has been reset.
Data Logger Manual Section 4: Front Panel Overview 4.1 Changing the display units The DLI2 comes with factory default display units of PSI for pressure and the real-time pressure graphing feature. These units can be easily changed by pressing the F3 button in the main screen and then selecting F1 for pressure or F2 for the pressure graph. After selecting the channel, the available units can be scrolled through by either pressing the channel’s function key repeatedly or using the UP and DOWN keys.
Dwyer DLI2 4.3 Checking the memory status A status icon appears on all screens representing memory, but further information including percent memory left and number of readings taken can also be viewed. From the Main Screen press the F1 key to enter the Status screens then press F2 to view memory status information. Button pressing chain: Main Screen -> F1 -> F2 4.
Data Logger Manual Section 5: DLI2 Function Reference 5.1 Main Screen The main screen of the DLI2 features a real-time display of most recently measured pressure data and a real-time graph of the 100 most recently recorded data points. At the bottom of the main screen are tabs corresponding to each of the four function keys. These tabs are used to access the four main function menus of the DLI2: status, statistics, units, and setup.
Dwyer DLI2 5.3 Statistics Menu Pressing the F2 key while in the Main Screen brings up the Statistics Menu. From the Statistics Menu, statistics generated from the conditions encountered by the device can be viewed in a variety of different styles including being sorted by channel and by type. The Statistics Menu also displays important statistics information as well as the option to clear the statistics at any time. 5.3.
Data Logger Manual 5.4 Units Pressing the F3 key while viewing the Main Screen will access the Units Selection screen. Here the measurement units can be easily changed. In the Units Selection screen the F1 function key corresponds to the pressure channel and the F2 key corresponds to the pressure graph.
Dwyer DLI2 Note: Use of the DLI2’s graphing function will reduce the battery life of the device, particularly when not logging. To increase battery life either deactivate the graphing function by turning it to “Hide” in the Adjust Visibility screen, increase “auto time” in the Display Update Mode screen, or change the Graph Source from ‘auto’ to ‘reading’. Alternatively, use the AC adapter for continuous power and graphing ability. 5.5.i.
Data Logger Manual Display The DLI2’s LCD has options to be either on continuously or turn off automatically after five minutes of inactivity. This option can be changed by first pressing the F1 key to highlight the display parameter configuration tab. Once the tab is highlighted the option can be changed by pressing the F1 key repeatedly or using the UP and DOWN keys to select either “On” or “Auto”. Backlight Like the display, the LCD backlight also has power saving options.
Dwyer DLI2 5.5.ii.c Power Status Selecting “MORE” by either pressing the F4 key or the OK key while viewing the Display Update Mode screen brings up the Power Status screen. On this screen the battery type is displayed and should be changed by the user based on whether a Lithium or Alkaline battery is used in the DLI2. This can be changed by first pressing the F1 button to highlight the type parameter configuration tab.
Data Logger Manual 5.5.iii.d Device Version Pressing the F4 key while viewing the Maximum or Minimum Device Range screens will display the Device Version screen, containing information such as firmware revision number and communications baud rate. Values on this screen cannot be modified. 5.5.iii.e Firmware Version Firmware details can be viewed by pressing the F2 key while viewing the Device Version screens.
Dwyer DLI2 Section 6: DLI2 Screen Descriptions 6.1 Main Screen: Displays last measured values. F1 = STATUS: enters status screens F2 = STATS: shows statistics menu F3 = UNITS: enters unit selection screen F4 = SETUP: enters device configuration menu CANCEL = no function OK = no function UP = no function DOWN = no function 6.
Data Logger Manual OK = returns to main screen UP = no function DOWN = no function 6.3 Status Screens (Memory Status): Displays information about the device’s memory capabilities including percent of memory available (memory left), number of readings taken so far (readings), max number of readings (max readings), and wrap status.
Dwyer DLI2 F3 = TIME: displays date and time screen F4 = MORE: displays ID parameters status screen CANCEL = returns to main screen OK = returns to main screen UP = no function DOWN = no function 6.5 ID Parameters Displays information relating to device identity. For all status screens: F1 = ID: no function F3 = MORE: displays run parameters screen F4 = EXIT: returns to main screen CANCEL = returns to main screen OK = returns to main screen UP = no function DOWN = no function 6.
Data Logger Manual CANCEL = returns to main screen OK = returns to main screen UP = no function DOWN = no function 6.7 Channel Statistics: Displays statistics (maximum recorded value, minimum recorded value, and average recorded value) for the pressure channel. F1 = PRESS: Displays pressure statistics F2 = no function F3 = no function F4 = EXIT: returns to Statistics Menu Screen CANCEL = returns to Statistics Menu OK = returns to Statistics Menu UP = no function DOWN = no function 6.
Dwyer DLI2 F4 = EXIT: returns to Statistics Menu CANCEL = returns to Statistics Menu OK = returns to Statistics Menu UP = no function DOWN = no function 6.9 Statistics Information Screen: Displays current statistics information including the number of recorded readings, start date, and start time.
Data Logger Manual F4 = OK: returns to Main Screen Note: Unit selection can be changed by pressing the corresponding function key repeatedly or using the UP and DOWN arrows to select appropriate units. CANCEL = returns to main menu without accepting changes OK = accepts changes and returns to main menu 6.11 Device Configuration Menu: Displays options available within the device configuration menu.
Dwyer DLI2 F3 = SOURCE: first highlights and then changes the option for how often the graphing feature will update F4 = MORE: moves on to Display Configuration screen CANCEL= return to Display Configuration Menu OK = moves on to Display Configuration screen UP = once channel parameter configuration tab is highlighted scrolls through available options DOWN = once channel parameter configuration tab is highlighted scrolls through available options 6.
Data Logger Manual 6.14 Power Modes Screen: Displays information regarding the devices different power modes including the display visibility, backlight options, and LED modes.
Dwyer DLI2 F4 = MORE: moves to Power Status screen CANCEL = returns to Device Configuration Menu OK = moves to Power Status screen UP = once parameter configuration tab is highlighted scrolls through available options DOWN = once parameter configuration tab is highlighted scrolls through available options 6.16 Power Status Screen: Displays details about power available to the device including the battery type, battery voltage, and external voltage.
Data Logger Manual For all Device Information Screens: F1 = MIN: no function F2 = MAX: shows Device Range (Maximum) screen F3 = CAL: shows Calibration Information screens F4 = MORE: shows further Device Information screens CANCEL = returns to Device Configuration Menu OK = returns to Device Configuration Menu UP = no function DOWN = no function 6.18 Device Information Screens (Maximum Device Range): Displays values indicating maximum pressure detectable by the DLI2. 6.
Dwyer DLI2 6.20 Device Information Screens (Firmware Version): Displays device firmware version information. F1 = VERS: shows Device Version screen F2 = FIRM: no function F3 = MORE: shows Device Range (Minimum) screen F4 = EXIT: returns to Device Configuration Menu CANCEL = returns to Device Configuration Menu OK = returns to Device Configuration Menu UP = no function DOWN = no function 6.
Data Logger Manual 6.22 Calibration Information Screens (Pressure Calibration): Displays calibration information for pressure channel. For all Device Information Screens: F1 = DATE: returns to Calibration Date screen F2 = PRESS: no fucntion F4 = EXIT: returns to Device Information screens CANCEL = returns to Device Information screens OK = returns to Device Information screens UP = no function DOWN = no function 6.
Dwyer DLI2 6.24 Device Reset Screen (Power Interruption): Displayed as notification when power is interrupted during device operation.
Data Logger Manual Section 7: Computer Interface: 1. Insert the USB connector of the DL700 into an available USB port. Fully insert male connector of the DL700 interface cable into the female receptacle of the data logger*. *WARNING: Install driver before connecting a device using a USB for the first time. See the Dwyer Data Logger Software manual for further information.
Dwyer DLI2 Section 9: Maintenance BATTERY WARNING Many Dwyer data loggers contain a lithium battery. Do not cut the battery open, incinerate, or recharge. Do not heat lithium batteries above the specified operating temperature.* Dispose of the battery in accordance with local regulations. *See the individual specification sheets at www.Dwyer-inst.com. The DLI2 does not have any user-serviceable parts except the battery which should be replaced periodically.
Data Logger Manual Section 10: Terms and Conditions All products furnished by Dwyer, Inc. (“Seller”) shall be in accordance with the following terms and conditions unless otherwise stated in writing: These Terms and Conditions (“Terms and Conditions”) govern (a) all sales quotations and sales of components, equipment, parts, and other products (“Product”) from, and (b) all service proposals and provisions of services by Seller to the buyer of the Products (“Buyer”).
Dwyer DLI2 defects that are found by Seller, or repair or replace F.O.B. point of manufacture that portion of the Seller manufactured Products, consumables or Software found by Seller to be defective, or refund the price of the defective portion of the Seller manufactured Products, consumables or Software, or of the defective portion of the Seller provided services.
Data Logger Manual OR ACCURACY, ADEQUACY OR COMPLETENESS OF DATA MEASUREMENT, WITH RESPECT TO ANY EQUIPMENT, COMPONENTS, PARTS, CONSUMABLES, SOFTWARE OR SERVICES SOLD TO BUYER BY SELLER THAT ARE NOT MANUFACTURED OR PROVIDED BY SELLER. Seller shall assign the manufacturer’s or service provider’s warranty applicable to such equipment, components, parts, consumables, Software and services to the extent permitted, to Buyer. Seller will provide Buyer with available warranty information. 10.2 Limitations.
Dwyer DLI2 the Software or merge it with another program; (iii) reverse engineer, disassemble, decompile, or make any attempt to discover the source code of the Software; (iv) translate or create derivative works based on the Software; (v) remove, obscure, or alter any notice of the patent, copyright, or other proprietary rights related to the Software; (vi) sub-license, sell, lend, rent, or lease any portion of the Software; (vii) copy any portion of the Software; (viii) operate the Software other than in
DLI2 Data Logger Manual P.O. Box 373 l 102 Indiana Hwy. 212, Michigan City, IN 46361 USA Phone: 219.879.8000 l Fax: 219.872.9057 www.dwyer-inst.com l info@dwyer-inst.