#@220/,9/=074,-70the Flotect
®
L4 Level switch operates automatically
to indicate tank level. Perfect for starting or stopping pumps, opening or
closing valves, or actuate level alarm signals. A unique magnetically
actuated switching design gives superior performance. There are no
bellows, springs, or seals to fail. Instead, the free-swinging float attracts
a magnet within the solid metal switch body, actuating a snap switch by
means of a simple lever arm. Float arm hinge design limits the arm angle
to prevent vertical hangup.
%&#$
• Leak proof body machined from bar stock
• Choice of floats dependent on maximum pressure and specific gravity
• Weatherproof, designed to meet NEMA 4
• Explosion-proof (listings included in specifications)
• Installs directly and easily into tank with a thredolet or flange
(see application drawings on page 4)
• Electrical assembly can be easily replaced without removing the unit
from the installation so that the process does not have to be shut down
• Horizontal installation or optional top mount vertical installation
!!% $
• Direct pump control for maintaining level
• Automatic tank dump operations
• Control levels or provide alarms in sumps, scrubber systems, hydro-
pneumatic tanks, low pressure boilers, and various waste
water/sewage treatment processes
$!% $
$0=A4.0 Liquids compatible with wetted materials.
(0??0/,?0=4,7>
Float and Rod: 316 SS;
Body: Brass or 316 SS standard;
Magnet Keeper: 430 SS standard, 316 SS or nickel optional.
%08;0=,?@=0 484?> 4 to 275°F (-20 to 135°C) standard, MT high
temperature option 400°F (205°C) [MT option not UL, CSA, ATEX or
IECEx]. ATEX and IECEx options: Ambient temperature -4 to 163°F (-20
to 73°C); Process temperature -4 to 163°F (-20 to 73°C).
!=0>>@=0484? Brass body 1000 psig (69 bar), 316 SS body 2000 psig
(138 bar). Standard float rated 100 psig (6.9 bar). For other floats see
model chart on next page.
9.7:>@=0#,?492 Weatherproof and Explosion-proof. Listed with UL
and CSA for Class I, Groups C and D; Class II, Groups E, F, and G.
ATEX 0344 II 2 G Ex d IIB T6 Gb -20°C≤Tamb≤73°C.
-20°C≤Process Temp≤73°C.
EC-Type Certificate No.: KEMA 03 ATEX 2383.
ATEX Standards: EN60079-0: 2009; EN60079-1: 2007.
IECEx Certified: For Ex d IIB T6 Gb -20°C≤Tamb≤73°C. -20°C≤Process
Temp≤73°C.
IECEx Certificate of Conformity: IECEx DEK 11.0071.
IECEx Standards: IEC 60079-0: 2007; IEC 60079-1: 2007.
$B4?.3%D;0 SPDT snap switch standard, DPDT snap switch optional.
70.?=4.,7 #,?492 UL, FM, ATEX and IECEx models: 10A @ 125/250
VAC (V~). CSA models: 5A @ 125/250 VAC (V~); 5A res., 3A ind. @ 30
VDC (V ). MV option: 1A @ 125 VAC (V~); 1A res., .5A ind. @ 30 VDC
(V ). MT option: 5A @ 125/250 VAC (V~). [MT and MV option not UL,
CSA, FM, ATEX or IECEx].
70.?=4.,7:990.?4:9>UL and CSA models: 16 AWG, 6˝ (152 mm)
long. ATEX and IECEx unit: terminal block.
!=:.0>>:990.?4:9 1-1/2˝ male NPT standard, 2-1/2˝ male NPT
standard optional floats.
:@9?492 =409?,?4:9 Horizontal installation standard, optional vertical
top mount.
(0423? 4 lb 9 oz (2.07 kg).
0,/,9/3/4˝ (19 mm) for standard float.
$;0.414.=,A4?D 0.7 minimum with standard float. For other floats see
model chart.