Instruction Manual

@770?49
$;0.414.,?4:9>9>?,77,?4:9,9/ ;0=,?4929>?=@.?4:9>
7:,?$B4?.3
(#$ '(*#$%#&%$
!  )O%*&$
!3:90 BBB/BD0=49>?.:8
,C 08,47491:/BD0=49>?.:8
$0=40>
#@220/,9/=074,-70the Flotect
®
L4 Level switch operates automatically
to indicate tank level. Perfect for starting or stopping pumps, opening or
closing valves, or actuate level alarm signals. A unique magnetically
actuated switching design gives superior performance. There are no
bellows, springs, or seals to fail. Instead, the free-swinging float attracts
a magnet within the solid metal switch body, actuating a snap switch by
means of a simple lever arm. Float arm hinge design limits the arm angle
to prevent vertical hangup.
%&#$
Leak proof body machined from bar stock
Choice of floats dependent on maximum pressure and specific gravity
Weatherproof, designed to meet NEMA 4
Explosion-proof (listings included in specifications)
Installs directly and easily into tank with a thredolet or flange
(see application drawings on page 4)
• Electrical assembly can be easily replaced without removing the unit
from the installation so that the process does not have to be shut down
Horizontal installation or optional top mount vertical installation
!!% $
Direct pump control for maintaining level
Automatic tank dump operations
Control levels or provide alarms in sumps, scrubber systems, hydro-
pneumatic tanks, low pressure boilers, and various waste
water/sewage treatment processes
$!% $
$0=A4.0 Liquids compatible with wetted materials.
(0??0/,?0=4,7>
Float and Rod: 316 SS;
Body: Brass or 316 SS standard;
Magnet Keeper: 430 SS standard, 316 SS or nickel optional.
%08;0=,?@=0 484?> 4 to 275°F (-20 to 135°C) standard, MT high
temperature option 400°F (205°C) [MT option not UL, CSA, ATEX or
IECEx]. ATEX and IECEx options: Ambient temperature -4 to 163°F (-20
to 73°C); Process temperature -4 to 163°F (-20 to 73°C).
!=0>>@=0484? Brass body 1000 psig (69 bar), 316 SS body 2000 psig
(138 bar). Standard float rated 100 psig (6.9 bar). For other floats see
model chart on next page.
9.7:>@=0#,?492 Weatherproof and Explosion-proof. Listed with UL
and CSA for Class I, Groups C and D; Class II, Groups E, F, and G.
ATEX 0344 II 2 G Ex d IIB T6 Gb -20°C≤Tamb≤73°C.
-20°C≤Process Temp≤73°C.
EC-Type Certificate No.: KEMA 03 ATEX 2383.
ATEX Standards: EN60079-0: 2009; EN60079-1: 2007.
IECEx Certified: For Ex d IIB T6 Gb -20°C≤Tamb≤73°C. -20°C≤Process
Temp≤73°C.
IECEx Certificate of Conformity: IECEx DEK 11.0071.
IECEx Standards: IEC 60079-0: 2007; IEC 60079-1: 2007.
$B4?.3%D;0 SPDT snap switch standard, DPDT snap switch optional.
70.?=4.,7 #,?492 UL, FM, ATEX and IECEx models: 10A @ 125/250
VAC (V~). CSA models: 5A @ 125/250 VAC (V~); 5A res., 3A ind. @ 30
VDC (V ). MV option: 1A @ 125 VAC (V~); 1A res., .5A ind. @ 30 VDC
(V ). MT option: 5A @ 125/250 VAC (V~). [MT and MV option not UL,
CSA, FM, ATEX or IECEx].
70.?=4.,7:990.?4:9>UL and CSA models: 16 AWG, 6˝ (152 mm)
long. ATEX and IECEx unit: terminal block.
!=:.0>>:990.?4:9 1-1/2˝ male NPT standard, 2-1/2˝ male NPT
standard optional floats.
:@9?492 =409?,?4:9 Horizontal installation standard, optional vertical
top mount.
(0423? 4 lb 9 oz (2.07 kg).
0,/,9/3/4˝ (19 mm) for standard float.
$;0.414.=,A4?D 0.7 minimum with standard float. For other floats see
model chart.