User Manual
1
5011654201-SCD1
2007-01-12
  SCD1000/2000 
Temperature Controller 
Instruction Sheet 
Thank you very much for choosing Love Controls SCD Series Temperature Controller. Please read this 
instruction sheet before using your SCD series to ensure proper operation and please keep this instruction sheet 
handy for quick reference. 
1
PRECAUTIONS 
DANGER: ELECTRIC SHOCK! 
SCD1000 is an OPEN-TYPE Process Control Equipment and SCD2000 is an OPEN-TYPE Process Control 
Accessory. These devices are microprocessor-based temperature regulating controllers which may be 
provided with normally closed and/or open contacts. They are intended for installation completely within an 
overall panel or process control enclosure and are used in heating or cooling applications. Please 
Install within 
a separate UL Listed enclosure only, keep the enclosure away from airbome dust 
or high humidity and prevent 
electric shock or sudden shock. Also, it is equipped with protective methods such as some special tool or key 
to open the enclosure, so as to avoid the hazard to users or any damage to the controller. 
1.  Prevent dust or metallic debris from falling into the controller that will cause malfunction.   
2.  Do NOT modify or disassemble the controller.   
3.  Do NOT connect the controller to “No Used” terminal. 
4.  Do not install and/or use the controller in places of: 
(a) dust or corrosive gases and liquid; (b) high humidity and high radiation; (c) vibration and shock; (d) high 
voltage and high frequency. 
5.  Switch of the power when wiring and changing the input sensor. 
6.  Make sure to use compensating wires that match the thermocouple types when extending or connecting the     
thermocouple wires. 
7.  Shorten the wire when wiring a platinum resistance thermometer (RTD) to the controller and separate power 
cable from load wires to prevent interference and conductive influence. 
8.  Make sure power cables and signal devices are installed properly before switching on the power; otherwise 
serious damage may occur. 
9.  Do NOT touch the terminals or repair the controller when the power is switched on to prevent electric shock. 
10. Wait at least one minute after the power is switched off to allow capacitors to discharge, and DO NOT touch 
any internal circuit within this period. 
11. Do NOT touch internal terminals no matter power is switched on or off. 
12. To ensure temperature accuracy, keep the controller away from the heating source. 
2
MODEL NAME EXPLANATION 
SCD    SCD series Temperature Controller 
 1  Controller Position 
1: first controller 
2: controller in parallel 
  2 Auxiliary Output 
Groups 
0: standard, 2 groups output, no auxiliary output 
1: 1 group auxiliary output. Not available now. 
2: 2 groups auxiliary output. Not available now. 
 3 4  Optional 
00: standard 
01: CT input. Not available now. 
02: Event input. Not available now. 
 5 Main Output Type 
R: Relay output SPST, 250VAC, 3A 
V: Voltage Pulse output 12V +10%~ -20% 
C: Current output 4 ~ 20mA 
L: Linear Voltage output 0 ~ 10V 
 Standard: DC24V input, Relay output for 2
nd
 group, RS-485 communication. 