User guide
Series SVT Solenoid Valve Enclosure with Timer
Specifications - Installation and Operating Instructions
Bulletin V-SVT
The  Series  SVT  Solenoid  Valve  Enclosure  with  Timer is  a
compact, reliable and economic package designed for small to
medium  filtration  systems.  It  combines  a  timer  board  and
solenoid valve enclosure into one package, eliminating the need
for separate enclosures and wiring. The SVT is available with 2,
4  or  6  valves.  For  larger  systems  expansion  modules  can  be
daisy  chained  to  the  SVT  for  a  maximum  of  60  outputs.  The
universal power supply accepts 90-240 VAC at either 50 or 60
Hz  for  both  domestic  and  international  requirements.  On-
Demand Cleaning  or Down  Time  Cleaning functions  can be
selected  with  a  simple  dip-switch.  Time-On  and  Time-Off
settings are selected using two potentiometers. 
For on demand systems, a  Dwyer
®
A3000 Photohelic
®
gage or
Series 1950 pressure switch may be used with the SVT. 
APPLICATIONS
• Dust Collection
• Pneumatic Conveying
• Down Draft Tables
• Industrial Vacuums
Installation
Warning:  Before  installation  make  sure  all  air
pressure has been released, electric power has been
turned  off,  and  air  pressure  sources  have  been
closed.  Turn  power  on  and  increase  pressure  only
after installation in completed. 
Location
Select a location  that  will  not  exceed the ambient temperature
specifications. The system must  be  located in area  that meets
enclosure ratings. The SVT can be mounted in any position. For
optimum life and performance it is recommended that the unit is
mounted horizontal and upright to reduce the chance of foreign
matter accumulating in the valves. 
DWYER INSTRUMENTS, INC. 
Phone: 219/879-8000 www.dwyer-inst.com
P.O. BOX 373 • MICHIGAN CITY, INDIANA 46360, U.S.A.  Fax: 219/872-9057 e-mail: info@dwyer-inst.com
SPECIFICATIONS 
Service: Compatible gasses, filtered and oil free.
Wetted Materials: Brass (pilot body), 302 SS (spring), NBR
(diaphragm).
Temperature Limits: 14 to 140°F (-10 to 60°C). 
Pressure Limit: 145 psi (10 bar).
Power Requirements: SVT: 90 to 240 VAC, 50 to 60 Hz;
SVT-DC: 24 VAC/VDC ±18%. 
Power Consumption: 25 VA.   
Fuse: 0.5 A delayed.    
Electrical Connection: 2 DIN 43652 connectors.
Enclosure Rating: NEMA 4X (IP65).
Enclosure Material: Polyamide with carbon fiber,
polycarbonate, TPE rubber.
Process Connection: 1/4˝ OD Push to Connect. 
Mounting Orientation: Any position.
On-Time: 150 msec to 700 msec.
Off-Time: 4 seconds to 210 seconds.
Pneumatic Connections
Verify  that  the  supply  pressure  is  within  the  required
specification.  Do  not  turn  on  the  system  before  installation  is
complete. Make  sure that  there is no  dirt or  other particles
between the RDCV diaphragm valve and the connections of the
SVT remoted solenoid valve, which would cause a restriction of
airflow. There should be no condensed water in the piping. The
use  of a  filter  may be  required to  avoid  this problem.  Leak
testing should be done prior to installation only.
2
-7/16
[
61.77]
9-55/64
[250.49]
9
-5/8
[
244.48]
5-3/16
[131.80]
TM