User Manual
22of30 MN890570 RevA
INSTALLATION StepNine
3. Flange(SeriesULSS&ULSM):Ifinstallingonaflange,selecta flangewithathreadthatisabovethe
planeoftheflange,suchastheULS‐ACC‐312.
a. TheSeriesULSLworkswellwithflangeinstallations.
b. Avoidtheuseofblindflangeswithtappedthreadsorflangeswherethethreadsareevenwith
theplaneoftheflange,suchastheBanjo1"PolyANSIFlange(seriesAF100).
c. Useaflangewitha2”threadandadda2”to1”reducerbushingtocompletetheinstallation.
2”Flangew/
threadoutofplane
(ULS‐ACC‐312)
1”Flangew/
threadinplane
2”Flangew/
reducerbushing
(ULS‐ACC‐121)
Donotusethreadinplane
4. SideMountBracket:Forinstallationsinopentanksandsumps,usetheULS‐ACC‐510orULS‐ACC‐520
sidemountbracket.
a. FortheSeriesULSS&ULSM,ordertheULS‐ACC‐510,whichincludesa2”x1”ReducerBushing.
b. FortheSeriesULSL,ordertheULS‐ACC‐520sidemountbracket.