User Manual
Rev5 MN890570 25of30
ADVANCEDFEATURES StepTen
IncreaseOutputFiltering:Placing acheckmarkintheboxwillincreasethe filtering(averaging)ofthe
analogoutput.Usethis filterif the 4to 20mA outputrequiresasmoothoutputforthe application
suchasopenchannelflowmeasurement.
DecreaseOutputFiltering:Placingacheckmarkintheboxwilleliminateallfiltering(averaging)ofthe
analogoutput.Enablesapulsebypulselevelreading.Usethisfiltertoseechangesinlevelafterevery
soundpulse.
Note:Nevercheckincreaseoutputfilteringanddecreaseoutputfilteringatthesametime.
StabilizeOutputinDead band:Placingacheckmarkintheboxwillactivateafiltertoholdtheoutput
atFullLevelifthelevelentersthedeadbandoftheSeriesULS.Thisfilterrequiresthe leveltoleave
thedeadbandatasmoothandsteadyrate.
Turn
OFFFastLevelChanges:Placingacheckmarkintheboxwillturnoffthefilterenablingfastlevel
changes.Usethisfilterifyourapplicationhasverysmooth,slowandsteadylevelchanges.Thefilter
instructsSeriesULStolookonlyforsmallincrementalchangesinlevel.
Turn ON Noisy Mount Start Filter: Placing a checkmark inthe box will activate a filter that reduces
soundinterferencefromtheinstallationmount.UsethisfilteriftheSeries ULSwillnotgotofullrange
intheinstallation.
InvertRelayStates:Placingacheckmarkinanyofthefourboxeswillreversethestateofthatrelay.
Forexample,ifrelay4isahighalarmthatenergizesabove50”ofliquid,checkingtheinvertboxwill
reversesotherelaywillenergizewhenitisbelow50”ofliquid.Invertingtherelaywillalsoinvertthe
fail‐safeoftherelay.Iftherelayisfail‐safeOn,invertingtherelaywillmakeitfail‐safeOff.
Fail‐Safewillalsoinvertunlessyoucheckbelow:Thisbuttonwill notinvertthefail‐safewhenarelay
isinverted.