Manual

A
ll notes are explained in section 5.4.
Page 11
L
PST (
1
4
)
Low power timer
1-99999, 0.150 8.000,
1-99999, 0.150 8.000, 0-1, 0-1
Long standby interval in minutes
Distance to low level in meters
Short standby interval in minutes
D
istance to high level in meters
D
isable (0) or enable (1)
0
- No SMS are sent when in the “Long Standby Mode”. 1 – SMS are sent
w
hen in “Long Standby Mode”.
C
ommunication and Alert Items (Metric)
Item
A
PP (
1
)
E
MP (
2
)
FUL (
2
)
VAL (
3
)
UNT (
3
)
UNT (
3
)
FBD (
2
)
N
BD (
2
)
R
AT (
4
)
TMP (
5
)
SNS (
5
)
RSD (
6
)
RSC (
6
)
RST (
6
)
GMAN
ENDT (
8
)
DSDT (
8
)
CUB (
7
)
CYLV (
7
)
CYLV (
7
)
CYLH (
7
)
CYLH (
7
)
TEL1 (9)
TEL1 (
9
)
SMST (
10
)
AFE (
11
)
ATF (
12
)
ATF (
12
)
ARF (
13
)
ARF (
13
)
Description
A
pplication type
E
mpty level
Full level
Value to display
U
nits for VAL=1,2,4,5
Units for VAL=3,6
Far blocking distance
N
ear blocking distance
F
illing (tracking) rate
Temperature unit system
Temperature sensor
Reset to factory defaults
Reset hour counter
Restart ULTM
Get manufacturer data
Enable USB monitoring
Disable USB monitoring
Cubic tank
Vertical cylindrical tank
Vertical cylindrical tank
with concave bottom
Horizontal cylindrical tank
with curved sides
Horizontal cylindrical tank
with flat sides
Cell-phone destination
SMS periodic interval
Full / Empty alerts
Theft alert for VAL=1,2,4,5
Theft alerts for VAL=3,6
Refill alerts for
VAL=1,2,4,5
Refill alerts for VAL=3,6
P
ossible values
0
1
0.50 – 26.00
0.50 – 26.00
1
2
3
4
5
6
1
2
3
4
0.50 – 26.00
0.50 – 26.00
0
1
2
3
3
4
0
1
2
None
None
None
None
None
None
0.00-300.00, 0.00-300.00
0.00-300.00, 0.00-300.00, 0
0.00-300.00, 0.00-300.00,
0.01-300.00
0.000-99.99, 0.000-99.99,
0.001-99.99
0.000-99.99, 0.000-99.99, 0
XXXXXXXXXXXXXX
XXXXXXXXXXXXXX
0
180-3999999
0
1
0, 0
0.16-4.00, 0
0, 0
0.16-4.00, 0
0, 1.4-26.00
0, 0, 1
0.16-4.00, 0, 1-3
0, 0, 1
0.16-4.00, 0, 1-3
0, 0.8-26, 1-3
Basic Setup (English)
Advanced Setup (English)
Resetting and ID Options (English)
Tank Shapes and Dimensions (English)
5
.3 List for English Unit System
Communication and Alert Items (English)
V
alue description
H
igh power
Low power
Distance in feet
Distance in feet
L
evel
D
istance
V
olume (set also tank shape)
% Level
% Distance
% Volume (set also tank shape)
Meter (see list for metric units)
F
eet
L
iter (see list for metric units)
G
allons (US)
Distance in feet
Distance in feet
3 feet / minute
6
feet / minute
1
5 feet / minute
30 feet / minute
Celsius
Fahrenheit
Internal sensor
External sensor
Average of both
Response is serial number and manufacturer date: dd-mm-yyyy
-
Width and depth (horizontal dimensions) in feet
Height of tank = EMP value in feet
Diameter of tank in feet
Height of tank = EMP value in feet
Diameter of tank in feet
Breadth of bottom in feet
Length, diameter and curved breadth in feet
Length and diameter in feet
Exactly 14 digits where X is any digit 0-9 or *,+,-
No periodic reports
Interval in seconds
No alerts
Alerts activate
No alerts
Normal consumption in inch/minute
No alerts
Normal consumption in inch/minute
Normal consumption in gallon/minute
No alerts
Minimal alerted level change in inch and minimum fill duration in minutes
No alerts
Minimal alerted level change in inch and minimum fill duration in minutes
Minimal alerted level change in gallons and minimum fill duration in minutes