Manual
8
. SIM Card*
A
Mini-SIM card must be inserted in the Series ULTM to allow use of the cellular
f
eature. Never insert or take out a SIM card when Series ULTM power is on. Follow
these instructions regarding your SIM card:
8.1 The SIM card must support SMS services with your local cellular operator. You
d
o not need any voice or browser capabilities in your cellular service.
D
epending on your cellular operator – you might be required to use a USIM
c
ard.
8
.2 Deactivate the SIM PIN code if the PIN code is active before inserting in the
ULTM. Deactivation is preformed by inserting the SIM card into a cellular phone
and following the instructions of the phone manufacturer. PIN code
configuration is usually found in your phone Settings – Security Settings – PIN
C
ode Request or similar.
8
.3 Always test your SIM card before inserting into Series ULTM. Test the SIM card
b
y inserting the card into a cellular phone and sending an SMS. Verify that no
PIN code is required, that the proper operator serves the cellular link and that
the SMS reaches its destination.
8.4 Turn off Series ULTM. Turn the Series ULTM top cap counter-clockwise and
expose the electrical connections board. Insert the SIM card into the proper slot
a
s described in the following figure. The SIM may be pulled out by pressing it
d
ownward again. Insert as shown in Figure 9 below.
8.5 Aim Series ULTM to proper target (e.g. floor), turn on Series ULTM and closely
observe the lower status line on the display (status lines are explained in the
Operating Instructions Chapter 3- Measurement Screen sub-chapter).
You should observe the report “GSM Initializing” for 30 to 60 seconds. Then you
should observe several additional status reports including “GSM Active”. This
indicates proper SIM card operation.
*Series ULTM only supports AT&T and T-Mobile mini-SIM cards. Make sure unit will
work with carrier.
Chapter 3. Operating Instructions
This chapter describes the keypad and display of the Series ULTM. The keypad
and display add the following functionality to Series ULTM:
• Viewing measurement results and viewing information related to the system
• Configuring Series ULTM
This chapter focuses on the structure and operation of the keypad and display.
Configuration of the system via a PC is described in following chapters. Expose the
keypad by turning the cap counterclockwise all the way.
1. Keypad
1.1 Navigation Keys
Use the navigation keys to scroll through the display.
Page 5
Figure 9: SIM Card.
1
. Choosing Location
D
istance to Tank Walls
Flange
Acoustic Noises
E
lectrical Interference
T
ank Installation
Sensor
E
xternal Thermistor
2
. Handling Dead Zone
E
xtension Pipes (1)
Extension Pipes (2)
E
xtension Pipes (3)
3
. Power Source
Voltage
Battery (Internal/External)
Ripple and Noise
T
ype
U
SB Power Source
4. Cellular Communications
SIM Card with SMS Service
Destination Phone Number
SMS Alerts
5. Measurement
Configuration
Full/Empty, Level/Distance
Filling Rate
False Echo Scan
Near Blocking Distance (NBD)
M
UST BE
M
UST BE
MUST BE
MUST BE
M
UST BE
M
UST BE
MUST BE
M
UST BE
MUST BE
MUST BE
M
UST BE
M
UST BE
MUST BE
M
UST BE
MUST BE
MUST BE
M
UST BE
MUST BE
MUST BE
MUST BE
MUST BE
MUST BE
A
t least 11.81˝ (30 cm) from walls
+
3.94/39.37˝ (+10 cm /1 m) range.
F
ixed on a horizontal surface.
Far away from acoustic noises and
vibrations.
Shielded away from power and sensor
c
ables.
F
ar away from tank inlets, outlets,
p
hysical obstacles.
E
xactly perpendicular to the surface of
the target.
In shaded location, attached to the tank
body.
O
f at least 3˝ (7.62 cm) internal
d
iameter and 5.91˝ (15 cm) above
target (from sensor face).
With completely smooth interior surface.
Installed with a flange/not protruding
into the tank.
A
t least 8 VDC on unit terminals.
R
ated higher than 8 VDC due to
voltage drop.
Not exceeding 100 mV.
P
referably regulated switching power
s
upply.
Accompanied by power source for field
operations.
Inserted in the SIM card slot.
S
et and formatted correctly.
Defined using correct limits.
Configured correctly.
Defined (consider the application).
Executed when the tank is empty.
Set up in flange and extension pipe
installations.
Figure 10: Navigation Keys.
9
. Must Be Pamphlet