Installation Sheet
a. Close toilet supply valve and ush tank completely. Towel or sponge remaining water from tank and bowl.
b. Disconnect and remove supply line. NOTE: If replacing valve, first shut off main water supply!
c. Remove old mounting hardware, remove toilet and plug oor waste opening to prevent escaping sewer gases.
d. Remove closet bolts from ange and clean away old wax, putty, etc. from base area.
NOTE: Mounting surface must be clean and level before new toilet is installed!
SAVE FOR FUTURE USE
2a
Elongated with Seat - Model# D2205CA.101
Round Front with Seat - Model# D2205DA.101
Fitzgerald
™
1.28 gpf / 4.8 Lpf 2-Piece Toilet
INSTALLATION INSTRUCTIONS
ROUGHING-IN DIMENSIONS:
IMPORTANT: Water supply on the wall is required at 3" (76 or 229mm) from centerline of the toilet (see rough-in). First
suggested position is hidden behind the toilet. The geometry of the toilet gives space for this installation. The second
suggested position is next to the toilet. Between these two positions, the space for the supply between wall and toilet
is limited to 3-1/2" (89mm). In this case, check your supply and hose dimensions.
Product names listed herein are trademarks of AS America, Inc.
© AS America, Inc. 2013
REMOVE OLD TOILET
1
CAUTION: PRODUCT IS FRAGILE. TO AVOID BREAKAGE AND POSSIBLE INJURY HANDLE WITH CARE!
NOTE: Pictures may not exactly define contour of china and components.
Thank you for selecting DXV by American Standard. To ensure this product is installed properly, please read these instructions carefully
before you begin. (Certain installations may require professional help.) Also be sure your installation conforms to local codes.
!
Most of the procedures require the use of common tools and materials, which are available from hardware and plumbing,
supply stores. It is essential that the tools and materials be on hand before work is begun.
RECOMMENDED TOOLS AND MATERIALS
Adjustable Wrench GasketWax Ring
Regular Screwdriver
10'
Level Flexible Supply Tube
Closet Bolts
Putty Knife
Tape Measure
Hacksaw
Sealant
7302031-100 Rev. A
29-7/8"
(758mm)
7-7/16"
(189mm)
1"
(26mm)
18-1/2"
(470mm)
3-1/2"
(88mm)
3-3/8"
(85mm)
12"
(305mm)
14-1/2"
(368mm)
16-1/2"
(419mm)
15-1/16"
(383mm)
31-3/16"
(792mm)
FINISHED
FLOOR
C/L OF SEAT POST
HOLES 5-1/2"
(140mm) CENTERS
SUPPLY
AS
REQUIRED
(position 1 or
position 2)
6"
(152mm)
5-1/2"
(140mm)
14"
(356mm)
9"
(229mm)
3"
(76mm)
13-1/2"
(342mm)
12-3/8"
(315mm)
NOTE: Distance from wall to closet flange centerline must be as listed below:
ALL INSTALLATION PROCEDURES MUST COMPLY IN STRICT ACCORDANCE WITH APPLICABLE LOCAL PLUMBING
AND BUILDING CODES
- 1 -