Installation Sheet

- 3 -
M965554 Rev. 1.6 (5/15)
5
ADJUST HOT LIMIT STOP (MUST BE DONE PRIOR TO TRIM INSTALLATION)
6 7
8
BACK TO BACK INSTALLATION
(SEE ILLUSTRATION STEP 8 FOR REFERENCE)
TEST INSTALLED FAUCET
TO GAIN ACCESS TO VALVE FOR SERVICING
Remove Handle and Trim from Valve.
See step 4 for reference.
Remove PRESSURE BALANCE UNIT (5).
Rotate PRESSURE BALANCE UNIT (5) 180˚ so that the
inlets face up and the large outlet port faces down.
Push PRESSURE BALANCE UNIT (5) in casting make sure
inlets line up with holes in bottom of casting. Top ange
should butt up against top of casting.
• Reassemble FIXATION RING (4) and CARTRIDGE (1).
• Turn VALVE “off”.
With HANDLE in “off” position, turn on water supplies
and check all connections for leaks.
Operate HANDLE and ush water lines thoroughly. Pull
DIVERTER and check SHOWER for proper operation.
• Check SPOUT and SHOWER connections for leaks.
• Remove Handle and Trim from Valve. See step 4 for reference.
• Shut off water supply by either closing off main water supply, or closing off the hot and cold CHECK STOPS on valve, if present.
VALVE LEAKS WHEN SHUT OFF
Remove CARTRIDGE (1) by removing CARTRIDGE SCREWS (2). Remove three SCREWS (3) from FIXATION RING (4) and
pull out PRESSURE BALANCING (5) unit.
Clean SEALS (9) on base of CARTRIDGE (1). Check base of PRESSURE BALANCING UNIT (5) and clean O-RINGS (6).
Remove CAPS (7) and check O-RINGS on inside of CAPS (7). Clean inside sealing surfaces of VALVE BODY (8).
Re-assemble PRESSURE BALANCING UNIT (5) and CARTRIDGE (1). Tighten all screws. Turn on water supply and see
above for installing TRIM and HANDLE.
UNABLE TO MAINTAIN CONSTANT TEMPERATURE
• Remove PRESSURE BALANCE UNIT (5). Remove CAPS (7) and clean valve thoroughly.
Examine balancing unit and check condition of O-ring on end of piston. Piston should move back and forth.
Order Repair Part M952100-0070A if balancing unit is defective.
Replace CAPS (7) and install PRESSURE BALANCE UNIT (5). Make sure inlets line up with two holes in bottom of casting.
Top ange should butt-up against top of casting.
1
5
1
3
1
1
9
7
5
3
1
0
1
5
1
3
1
1
9
7
5
3
1
1
5
1
3
1
1
9
7
5
3
1
COLDER
(Larger Numbers)
0 1 3 5 7 9 11 13 15
HOTTER
(Smaller Numbers)
0 1 3 5 7 9 11 13 15
1
5
1
5
4
4
3
3
2
2
By restricting HANDLE rotation and limiting the amount of hot water allowed to mix with the cold, the
HOT LIMIT SAFETY STOP (1) reduces risk of accidental scalding. To set the maximum hot water
temperature of your faucet, all you need to do is adjust the setting on the HOT LIMIT SAFETY STOP (1).
Turn CARTRIDGE STEM (2) to the OFF position (coldest setting) before making adjustment to
HOT LIMIT STOP (1). Use a at blade screwdriver to pry free the HOT LIMIT SAFETY STOP (1).
Pull forward and rotate counterclockwise one number to limit hot water temperature.
Use ARROW (3) on CARTRIDGE (4) and NUMBERS (5) on HOT LIMIT STOP (1)
for indication.
BACK TO BACK INSTALLATION
ROTATE 180
˚
1
9
5
5
7
8
6
4
3
INLETS
LARGE OUTLET
2