Installation Sheet

- 3 -
M965563 Rev. 1.9 (8/19)
3
4
4a
MAKE WATER SUPPLY CONNECTIONS
TEST INSTALLED FAUCET
Connect HOT water supply to LEFT INLET UNION (1)
and COLD water supply to RIGHT INLET UNION (2).
Pipe connections are 3/4" (19 mm) NPT. Use sealant
or Teon tape on pipe connections.
Do not solder directly to valve body.
Remove AERATOR from FAUCET.
With HANDLES in OFF position, turn
on WATER SUPPLIES and check all
connections for leaks.
Operate both HANDLES to ush water
lines thoroughly.
• Replace AERATOR.
Remove Hand Shower from the hose.
Turn water supplies on to ush water lines thoroughly.
Turn handles “off” and replace HAND SHOWER.
INSTALL VALVE BODIES
1-1/2''(38 mm) MAX.
6
1
3
4
8
12
HOT
13
14
9
11
10
7
5
2
"O" RING
TUB DECK OR
MOUNTING SURFACE
1A
HOT
COLD
3/4" (19mm) D.
3/4" X 3/4" NPT UNION
(NOT SUPPLIED) (19mm X 19mm)
HOT
COLD
3/4" NPT
(19 mm)
AERATOR
TRANSFER
KNOB
3/4" (19 mm) NPT
2
1
IMPORTANT: It is strongly recommended
that access be provided for all enclosed
mechanical parts to this system.
3
8
HAND SHOWER
HANDLE ASSEMBLIES (1, 1A) are installed on VALVE BODIES (2)
and must be removed to install VALVE BODIES (2) from under
tub deck or mounting surface.
• T o remove HANDLE ASSEMBLY (1), unthread HANDLE BASE (3)
with LEVER (4) from VALVE BODY (2). Pull HANDLE ASSEMBLY (1)
off VALVE STEM (5).
• Unthread and remove MOUNTING RING (6) and SPACER (7).
Thread LOCKNUT (8) to bottom of VALVE BODY (2). Make sure
FIBER WASHER (9) and RUBBER WASHER (10) are installed.
Insert VALVE BODY (2) through mounting hole from underside
of tub deck or mounting surface.
Note: VALVE BODY marked Hot is installed in the left Mtg.
hole, VALVE BODY marked Cold in the right when
facing front of fitting. Maximum mounting surface
thickness is 1-1/2" (38 mm).
From top install SPACER (7) onto VALVE BODY (2). Thread
MOUNTING RING (6) on VALVE BODY (2) until seated tightly against
SPACER (7). Set VALVE BODIES (2) so that their outlets are facing
toward SPOUT TEE (11) and then tighten LOCKNUT (8) using 35 mm
or adjustable wrench.
Insert FIBERWASHERS (12) into COUPLING NUTS (13) of SUPPLY HOSES (14) and tighten making water tight connection.
Important: Loop SUPPLY HOSES (14) as illustrated so they do not kink.
INSTALL HANDLES
Turn VALVE BODIES (2) to off position. Align HANDLES as shown or as desired and install HANDLE ASSEMBLY (1, 1A) onto
VALVE STEM (5). Thread HANDLE BASE (3) onto VALVE BODY (2) until seated tightly against mounting surface.