Installation Sheet

- 4 -
M965850 (8/17)
11
6
7
8
With HANDLE (1) in OFF position, turn on WATER
SUPPLIES (2) and check all connections for leaks.
• Remove AERATOR (3) using KEY (6).
• Operate HANDLES (1) to ush water lines thoroughly.
• Replace AERATOR (3) and tighten.
Operate POP-UP KNOB (5) and ll SINK with water. Check
that DRAIN STOPPER (4) makes a good seal and retains
water in Sink. If DRAIN STOPPER (4) does not
seal properly, please refer to “Troubleshooting Guide” in
these instructions.
Push POP-UP KNOB (5) down and check all drain
connections and “P” trap for leaks. Tighten if necessary.
TEST INSTALLED FITTING
CHECK DRAIN CONNECTIONS
1
5
1
2
2
3
6
4
5
HOT
COLD
“P” TRAP
WASTE
OUTLET
MAKE WATER SUPPLY AND WASTE CONNECTIONS
NOTE: FLEXIBLE SUPPLIES OR BULL-NOSE RISERS NOT INCLUDED
AND MUST BE PURCHASED SEPARATELY.
Connect water supply to VALVE BODIES (1,1A) with 1/2" IPS
FLEXIBLE SUPPLIES (2) or 3/8" O.D. BULL-NOSE RISERS (3).
Use adjustable wrench to tighten connections. Do not over tighten.
Be careful not to kink copper supply when bending. Use tubing
cutter to cut to proper length.
Connect HOT water supply to inlet of left SHANK and COLD
water supply to right SHANK using sealant, appropriate
connectors, and COUPLING NUTS.
HOT
COLD
FERRULE
COMPRESSION
NUT
COUPLING
NUT
FLEXIBLE
SUPPLIES
3/8 O.D.
BULL-NOSE
RISERS
1/2" PIPE
THREAD
3/8 COMPRESSION
CONNECTION
2
3
1A
1