Installation Sheet

- 5 -
M965829 (4/17)
5
MAINTANENCE
If water ow rate is lower than stated, ow regulator might be clogged by debris in the water lines.
Clean lter screen at inlet hoses.
TO REPLACE FLOW REGULATOR
• Turn water supplies off.
Use a SHARP TOOL (1) to loosen DECORATIVE RING (2). Figure A.
• Lift up DECORATIVE RING (2) and use hex key to remove SET SCREW (3). Figure B.
• Remove BASE (4) and pull whole handle assembly off. Figure B.
• Unthread CARTRIDGE NUT (5) to remove CARTRIDGE (6). Figure C.
• Replace FLOW REGULATOR (7) with new one.
• Follow the above steps in reverse to install faucet components.
Clean the Nozzles on the Aerator by massaging each nozzle using your nger.
6
CARE INSTRUCTIONS:
DO: SIMPLY RINSE THE PRODUCT CLEAN WITH CLEAR WATER. DRY WITH A SOFT COTTON FLANNEL CLOTH.
DO NOT: DO NOT CLEAN THE PRODUCT WITH SOAPS, ACID, POLISH, ABRASIVES, HARSH CLEANERS, OR A
CLOTH WITH A COARSE SURFACE.
1
2
Figure A.
Figure C.
Figure B.
2
3
6
4
5
7