Exploded Parts

- 1 -
INSTALLATION INSTRUCTIONS
Product names listed herein are trademarks of AS America, Inc.
© AS America, Inc. 2017
SAVE FOR FUTURE USE
M965842 (5/17)
Model D35120460
DXV
Grid Drain
ROUGHING-IN
DIMENSIONS:
• For reference
In the United States:
DXV
One Centennial Avenue
Piscataway, New Jersey 08855
Attention: Director of Customer Care
For residents of the United States, warranty
information may also be obtained by calling
the following toll free number: (800) 227-2734
www.DXV.com
In Canada:
DXV
5900 Avebury Road
Mississauga, Ontario
L5R 3M3
Canada
Toll Free: 1-800-387-0369
Local: 905-306-1093
Fax: 1-800-395-1498
www.DXV.ca
In Mexico:
DXV
Via Morelos 330
Col. Santa Clara Coatitla
Ecatepec, Estado de México 55540
Toll Free: 01-800-8391200
www.DXV.mx
Thank you for selecting DXV. To ensure that your
installation proceeds smoothly, please read these
instructions carefully before you begin.
2-3/8"
(60 mm)
7-11/16"
(195 mm)
1-1/4" O.D.
(32 mm)
WASTE
OUTLET
1-1/4" O.D.
TAILPIECE
1
2
Apply a bead of PUTTY to underside of
DRAIN BODY FLANGE (1).
• Feed DRAIN BODY (1)) down through lavatory.
Assembly GASKET (2) WASHER (3) and LOCKNUT (4)
onto DRAIN BODY (1). Tighten LOCKNUT (4) rmly.
• Assembly TAILPIECE (5) to DRAIN BODY (1).
Connect 1-1/4" O.D. tailpiece on
POP-UP DRAIN to waste outlet.
DRAIN INSTALLATION
CONNECT DRAIN
PUTTY
2
1
3
4
5
3
Check all drain connections and “P” trap for leaks.
Tighten if necessary.
CHECK DRAIN CONNECTIONS
“P” TRAP
WASTE
OUTLET