ASSEMBLY INSTRUCTIONS
Front View Rear View
Fully Assembled
The quick disconnect socket (Z) and supply gas line must be installed by a qualied service agency.
The supply connection must be made in accordance with local codes or, in the absence of local
codes, with either the National Fuel Gas Code, ANSI Z223.1/NFPA 54, in the USA, of the Natural
Gas and Propane Installation Code, CSA B149.1, in Canada.
A properly sized manual shut-off valve must be installed between the frill and the gas supply piping.
The grill and its individual shut-off valve must be disconnected from the gas supply piping system
during any pressure testing of that system at test pressures in excess of 0.5 PSI (3.5 kPa).
The grill must be isolated from the gas supply piping system by closing its individual manual shut-
off valve during any pressure testing of the gas supply piping system at test pressures equal to or
less than 0.5 PSI (3.5 kPa).
Always connect the exible gas supply hose to the gas supply before opening the manual shutoff
valve.
1. Ensure that the natural gas shut-off valve is closed.
2. Remove the protective rubber caps from the plug
and sleeve ends of the quick disconnect ttings.
Check that the ttings are clean.
3. Retract the sleeve on the coupling as illustrated.
4. Insert the plug and release the sleeve as illustrated.
5. Push the plug into the sleeve until the sleeve snaps
forward to lock the plug in the coupling.
6. Open the natural gas shut-off valve.
1. Close natural gas supply at shut-off valve.
2. Push the sleeve back and gently pull out the plug.
3. Replace the protective rubber caps on the plug and
sleeve ends of the quick disconnect couplings.
CONNECTING THE GRILL TO THE NATURAL GAS SUPPLY
TO CONNECT:
TO DISCONNECT:
Z
Retract Sleeve
Release Sleeve
Rear View
Front View
Fully Assembled