Use and Care Manual

PROPANE CONSTRUCTION HEATER
5
SPECIFICATIONS
USA 8-Hr Time weighted average
(OSHA 29 CFR 1926.55 App A)
CO 50 ppm
CO
2
5000 ppm
NO
2
USA – Ceiling Limit
(Short Term Exposure Limit = 15 minutes)
CO
CO
2
NO
2
5 ppm
Canada 8-hr time weighted average
WorkSafe BC OHS Guidelines Part 5.1
and Ontario Workplaces Reg 833
25 ppm
5000 ppm
3 ppm (Reg 833)
Canada STEL (15 minutes Reg 833/1 hour WSBC)
WorkSafe BC OHS Guidelines Part 5.1 and Ontario
Workplaces Reg 833
100 ppm
15000 ppm (WSBC)
30000 ppm (Reg 833)
1.0 ppm (WorkSafeBC)
5.0 ppm (Reg 833)
Ensure that the ow of combustion and ventilation air exchange cannot become obstructed.
As the building ‘tightens up’ during the construction phases ventilation may need to be increased.
Model No. FA 60 Series FA 125 Series
INPUT RATING 36000 BTU/hr , 60000 BTU/hr 70000 BTU/hr , 125000 BTU/hr
TYPE OF GAS PROPANE PROPANE
GAS SUPPLY PRESSURE TO REGULATOR MAXIMUM BOTTLE PRESSURE BOTTLE PRESSURE
MINIMUM (FOR PURPOSE OF INPUT ADJUSTMENT) 25 PSI / 172 KPa 25 PSI / 172 KPa
MANIFOLD PRESSURE 5 PSI 5 PSI
GAS CONSUMPTION (Lb/Hr) High-2.78 Low-1.67 High 5.79 Low-3.29
GAS CONSUMPTION (Kg/Hr) High-1.26 Low-0.76 High 2.63 Low-1.49
ELECTRICAL INPUT 120 V , 60 Hz 120 V , 60 Hz
AMPERAGE LOAD 0.22 AMPS 0.35 AMPS
IGNITION ELECTRONIC SPARK ELECTRONIC SPARK
SPARK GAP 4 mm (0.157”) 4 mm (0.157”)
SIZE (LxWxH)
43.9 cm x 19.8 cm x 35.1 cm
(17.3” x 7.8” x 13.8”)
56.9 cm x 22.1 cm x 43.7 cm
(22.4” x 8.7” x 17.2”)