Use and Care Manual
PROPANE CONSTRUCTION HEATER
9
INSTALLATION TO THE PROPANE GAS TANK
IMPORTANT: You must use a propane/LP gas supply cylinder that is compatible with the connection device 
provided with the hose and regulator.
REFILLING THE PROPANE GAS TANK
ALL NEW CYLINDERS MUST BE PURGED BEFORE THE FIRST FILLING.
• Turn heater gas valve knob and gas tank valve to OFF position.
• Propane tank valve equipped with the old style tting has LEFT HANDED THREADS. Turn POL tting
 CLOCKWISE to loosen. Protect POL tting when disconnected from tank.
• Have tank lled by your local Propane gas supplier.
• Fasten full Propane tank and connect POL tting to tank valve by turning COUNTERCLOCKWISE.
• With heater gas valve knob still in the OFF position, turn ON tank valve and check for leaks 
 with soap solution.
WARNING
: Purging and lling of LP gas tanks must be performed by personnel who
   has been thoroughly trained in accepted LP gas industry procedures. Failure to follow 
these instructions may result in explosion, re, severe personal injury, or death.
1. Provide propane/LP supply system. Ensure that the valve on the cylinder is fully closed by turning the knob 
 fully clockwise ( ). Ensure that the cylinder is fully upright for vapor withdrawl. (see size/capacity, page 7).
2. Connect hose to heater inlet. (See Figure 1). Tighten rmly using a wrench. You must use the regulator   
 supplied with heater.  
3. Connect fuel gas tting hose/regulator assembly to propane LP tank(s).
 (See gure 2) Turn POL Fuel tting counterclockwise into threads on tank. Tighten 
 rmly using a wrench. Some models have a hand wheel that can be used to tighten the tting. This hand 
 wheel can be slid off of the nut so that a wrench can also be used to tighten the tting. IMPORTANT: 
 Position regulator so that hose leaving the regulator is in a horizontal position.
4. Open propane/LP supply valve on propane/LP tank(s) slowly. NOTE: If not opened slowly, excess ow
 device in regulator may stop gas ow. If this happens, close propane/LP supply valve, wait one minute 
 (or until you hear a click) and open again slowly.
5. Check all connections for leaks. Apply a 50/50 solution of liquid dish soap and water to gas joints.
 Bubbles forming show a leak that must be corrected.
6. Close propane / LP supply valve before attempting to repair connection.
 FIGURE 2 
D
C
E
4
2 3
65 7 8 9
1
C
D
E
F
APPROVED FOR PRODUCTION
ECN# APPROVED
DATE
1 2
3
4
5
6
F
987
REV NO.
ECN NO.
REV DATE
REVISION DESCRIPTION
TOLERANCES UNLESS OTHERWISE SPECIFIED
±1.0mm
±.03inch
±2°Angular
±.08mm<=
∅12.7mm
±.003inch<=
∅0.50
±.25mm>
∅12.7mm
±.010inch>
∅0.50
BEND
RADIUS:
0.3970mm -0 +0.025 mm
0.0156inch -0 +0.001 inch
MATERIAL SPEC.
C
CRITICAL DIMENSION
DESCRIPTION
FINISH:
SCALE:DO NOT SCALE
DRAFTER
VERIFIED
APPROVED
DATE:
DATE:
DATE:
GHP GROUP INC
FIRST ANGLE
PROJECTION
FRONT
RIGHT SIDE
SHEETS:
1 of 1
MODEL NUMBER:
2019-4-3
FA60Q
Gavin TT
Yeah
Connector lnlet
Hose Fitting
Hose to Regulator
Connector Inlet
Hose to Regulator
Hose Fitting
 FIGURE 1 
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
Propane/LP
Supply Valve
Propane/LP
Tank
POL Fuel Gas
Fitting
Hose to Heater
Regulator