User Manual

LEGEND
T Included in Tune-Up Kit.
X Type of wear, no other
comments apply.
L Easily lost. Care during
assembly/disassembly.
D Easily damaged during
assembly/disassembly.
Parts Common to all Models:
Note: Please refer to page 4 of tool manual for specific part number.
Index Part Description Number High Wear Medium Wear Low Wear Non-Wear
# Number Required 100% 70% 30% 10%
1
See Note Back-Up Pad 1 X
2
See Note Lip-Seal Shroud 1 X
3
See Note Vacuum Shroud 1 X
4 57069 Balancer Shaft 1 X
5 95630 Snap Ring 1 L
6 59084 V-Seal 1 T
7 56052 Bearing 1 T
8
See Note Motor Shaft Balancer 1 X
9 56047 Key 1 T
10 57059 Lock Ring 1 X
11 95973 Washer 1 X
12 57055 Front Ring 1 X
13 57088 Bearing 1 T
14 57057 Front Bearing Plate 1 X
15 57113 Rotor/Blade Set 1 T
16 57058 Cylinder 1 X
17 95971 Line-Up Pin 1 T
18 57056 Rear Bearing Plate 1 X
19 01206 Bearing 1 T
20 57054 Rear Ring 1 T
21 95626 Snap Ring 1 T
22
See Note Housing 1 X
23 See Note Throttle Lever 1 X
24
94590 Pin
1
T
25 57041 Comfort Platform 1 X
26 95697 Retaining Ring 1 T
27 01464 Seal 1 T
28 01472 Tip Valve 1 T
29 01468 Spring 1 T
30 01494 Inlet Bushing 1 X
31 01025 O-Ring 2 T
32 01477 Valve Stem 1 T
33 57064 Speed Regulator 1 X
Machine Exhaust Parts (Reference page 5 for your machines specific components.)
1 69364 Shroud Adapter 1 X
2 57083 Vacuum Adapter 1 X
3 96197 Dowel Pin 1 L
4 57066 Muffler Body 1 X
5 95526 O-Ring 1 T
6 69353 Vacuum Nozzle 1 D
7 57067 Vacuum Tube 1 X
8 57093 Central Vacuum Adapter 1 X
9 56027 Muffler Inserts 3 T
10 69359 Muffler Body 1 X
57098 Full Service Repair Kit:
Includes special tools for proper
disassembly/assembly of the
Dynorbital
®
Supreme.
Includes: 57092 Repair Collar
56058 Lock Ring Wrench
56056 Bearing Puller
57091 Bearing Press Tool
57099 Bearing Puller
96034 12mm Hex Wrench
96066 3/4" Socket
96024 Tune-Up Kit
• Tune-Up Kit contains high
wear and medium wear parts.
This service chart is published as a guide to expectant life of component parts. The replacement levels are based on average tool usage over one
year. Dynabrade Inc. considers one year usage to be 1,000 hours.
Preventative Maintenance Schedule
For All Dynorbital
®
Supreme Sanders
7