Mini Speed Dome Camera Indoor Dome Camera Installation Guide Version 1.
Installation Guide Preface The information given in this manual was current when published. The company reserves the right to revise and improve its products. All specifications are subject to change without notice. Notice This manual provides the installation information for indoor Mini Speed Dome Cameras.
Installation Guide This symbol on the product or on its packaging indicates that this product shall not be treated as household waste in accordance with Directive 2002/96/EC. Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment. By proper waste handling of this product you ensure that it has no negative consequences for the environment and human health, which could otherwise be caused if this product is thrown into the garbage bin.
Installation Guide Warnings and Cautions • Handle the camera carefully Do not abuse the camera. Avoid striking, shaking, etc. The camera could be damaged by improper handing or storage. • Installing electricity wiring carefully Ask qualified personnel of electrical wiring for the installation. Please note that input electricity to the unit is at tolerance of DC 12V/AC 24V ± 10%.
Installation Guide • Never face the camera towards the sun Do not aim the camera at bright objects. Whether the camera is in use or not, never aim it at the sun or other extremely bright objects. Otherwise, the camera may be smeared or damaged.
Installation Guide Table of Contents 1. 2. 3. Introduction.................................................................................................................7 Standard Package Contents ......................................................................................8 Camera Setups and Cable Connections .................................................................10 3.1 3.2 4. Switch Definition .......................................................................................
Installation Guide Appendix A: Technical Specification .............................................................................
Installation Guide 1. Introduction The Mini Speed Dome Camera is a new subcompact high speed dome camera designed to deliver superb performance and durability with an intelligent and stylish housing that is suitable in any security and surveillance installation. General Operation Requirements: A minimum of one control device is required for operation, such as a Control Keyboard, a DVR or a PC. The Mini Dome Cameras contain a built-in receiver that decodes commands originating from a control device.
Installation Guide 2. Standard Package Contents Before proceeding, please check the box contains the items listed here. If any item is missing, or if damage is evident, DO NOT install or operate the product and contact your dealer for assistance.
Installation Guide Network Model Data Cable for Power Supply, Video and Audio Dome Camera (DC 12V) Power Adaptor & Power Cord Data Cable for Power Supply, Video and Audio (DC model only) (AC 24V) Hard Ceiling Mount M3 Screw, & Fixing Plate Decoration Ring Quick Guide CD: Operation Manuals 9
Installation Guide 3. Camera Setups and Cable Connections Before installing or connecting the Dome Camera, please refer to this section and complete preparation, switch setting and communication switch settings. 3.1 Dome Camera Setups Before connecting the Dome Camera to other devices of CCTV system, please complete the Dome Camera’s ID and communication switch setting. These switches are located on the bottom of the Dome Camera.
Installation Guide The ID and Protocol numbers of an analog camera are set with a 10-bit and 6-bit dip switch respectively using binary system. For switch configuration details, please refer to Appendix B: Switch Settings Index Table in Mini Speed Dome Camera’s User Manual. NOTE: Please NO NOT change the factory default Communication Switch settings of the network Speed Dome Camera. 3.1.2 Communication Switch Setting The analog Dome Camera’s communication switches are specified in the table below.
Installation Guide 3.1.3 ID Setup Please change the analog Dome Camera’s ID if there is more than one Dome Camera in the same network. Use the switch to change your Speed Dome Camera’s ID by setting the 10-bit dip switch. For instance, if the camera’s ID is 006, set the SW 8 and SW 9 to “ON,” with the rest to “OFF,” as shown below. For switch configuration details, please refer to Appendix B: Switch Settings Index Table in the Dome Camera’s User Manual.
Installation Guide 3.1.4 Camera Control Protocol Setup Define the protocol you are going to use basing on the devices of your surveillance system. Generally, use one protocol even the devices are provided from different manufacturers. Please refer to the table below for all supported protocols with their matching switch numbers and baud rate and choose a protocol for your Speed Dome Camera. Switch No.
Installation Guide 3.2 Cables and Connections The Dome Camera is supplied with one integrated 22-pin Data Cable for connecting with the power, video, and RS-485/audio input & audio output cables. Please read the following sections thoroughly before making connections. 3.2.1 Cable Requirements For operation, the Integrated High Speed Dome Cameras require video, RS-485 and power cables as described below: • The video cable sends video signals to a remote viewing site.
Installation Guide AC 24V Data Cable NOTE: Be careful not to pull the cables improperly during installation. Additionally, it is suggested to fasten the cables after cable connection is completed. Furthermore, when wiring the power cable, make sure the Ground wire inserted into the mid-pin of the terminal block. Network Model The network Speed Dome Camera’s Data Cables are illustrated as shown below. AC 24V Data Cable DC 12V Data Cable 3.2.
Installation Guide Analog Model The analog Dome Camera’s 22-pin connector definition is listed as follows: Pin Definition Cable Pin 1 AC 24-1/DC (+) 20AWG/18AWG 12 ALM-1 2 ALM NC 13 ALM-3 3 AC 24-2/DC (-) 14 ALM-2 4 ALM NO 15 ALM-4 5 FG 16 ALM-5 6 ALM COM 17 ALM-6 7 T+ 18 ALM-7 8 R- 19 ALM-8 9 T- 20 ALM GND 10 R+ 21 VGND 11 ISOG 22 Video 20AWG/18AWG 20AWG/18AWG 24AWG Definition Cable 20AWG Network Model The network Speed Dome Camera’s 22-pin connector d
Installation Guide 3.2.4 RS-485 Connector RS-485 is the interface that communicates the Dome Camera and its control device. Please connect the Control Keyboard to the Speed Dome Camera through the terminal block. The recommended cables for RS-485 communication are CAT 5 cables; maximum cable length for over 24-gauge wire is 4000 feet (1219 meters). If the total cable length exceeds 4000 feet, using a repeater to maintain the signals is recommended.
Installation Guide Insert the terminal into the pin holes on the connector housing, with the hook outward, as indicated in the figure. To unlock the terminal, press the hook, as indicated in the figure, with a proper tool and pull it out gently. Connect the 22-pin connector to its mating port on the back plate of the Dome Camera. NOTE: The figure on the right side is for illustration only. Please refer to section 3.1.1 Switch Definition for correct back plate layout. 3.2.
Installation Guide 4. Dome Camera Installation In the following sections, various Dome Camera installation accessories, installation methods and installation procedures will be described in detail. The next section will provide the Dome Camera’s dimensions for your reference before installation. 4.1 Camera Dimensions The indoor Dome Camera’s dimensions are Ø131 x 200 mm (5.2 x 7.9 Inches) as shown in the diagram below.
Installation Guide 4.2 Optional Accessories Indoor Dome Camera Accessories Power Adapter 77H07-A1015 (Input: 100~115VAC/Output: 24VAC 36VA 77H07-A2015 (Input: 220~230VAC/Output: 24VAC 36VA) NOTE: When wiring, make sure the Ground wire inserted into the mid-pin of the terminal block Mounting Accessories Indoor Mount Kit For mounting the indoor Dome Camera onto a Standard Pendent Mount/Straight Tube. White; Diameter: 140 mm (5.5 inches); Height: 74 mm (2.9 inches); 0.3 kg (0.
Installation Guide In-Ceiling (T-Bar) Mount For in-ceiling installation use. Diameter: 179.3 mm (7.1 inches); Height: 131.4 mm (5.2 inches). Ceiling Sticker: 162 mm (6.4 inches); Supplied with M3x6 screw x2, lock bar x1and ceiling sticker x1. Standard Pendent Mount White; 348×104×138.6 mm (13.7×4.1×5.5 inches); 1.5 kg (3.3 lbs); Diameter: 45 mm (1.8 inches). Supplied with M8x12 screw x1, spring washer-8 x1, pendent tube washer x1, rubber washer-8 x1 and sponge x2. Compact Pendent Mount White; 184×104×115.
Installation Guide Straight Tube White, Iron, Height: 250/500 mm (9.8/19.7 inches) ,Diameter: 50 mm (2 inches) 1 kg (2.2 lbs) / 1.8 kg (4 lbs), Supplied with M8x12 screw x1, spring washer-8 x1, pendent tube washer x1, rubber washer-8 x1 and waterproof rubber x1. Swan Tube For mounting with Swan Tube. White; Iron, Dimension: 835 x 300 mm (32.9×11.8 inches); Diameter: 45 mm (1.8 inches); Weight: 3.8 kg (8.
Installation Guide Corner Standard Mounting Plate White, 222×204×117 mm (8.7×8×4.6 inches); 2 kg (4.4 lbs); Supplied with washer-8 x4, spring washer-8 x4, M8x16 screw x4, and M8 nut x4. Corner Thin Box Mounting White/Ivory, 300×164×222 mm (11.8×6.5×8.7 inches); 3 kg (6.7 lbs); Supplied with M8x16 screw x4, washer-8 x4, and spring washer-8 x4. Corner Wide Box Mounting White/Ivory; 232×234×210 mm (9.1×9.2×8.3 inches); 2.7 kg (6 lbs); Supplied with M8x16 screw x4, washer-8 x4, and spring washer-8 x4.
Installation Guide Pole Thin Box Mounting White/Ivory; 291×136×242 mm (11.5×5.4×9.5 inches); 3.1 kg (6.9 lbs); Supplied with M8x16 screw x4, washer-8 x4, spring washer x4 and stainless steel straps x4. Pole Wide Box Mounting White/Ivory, 270×166×155 mm (10.6×6.5×6.1 inches); 3.2 kg (7.1 lbs); Supplied with M8x16 screw x4, washer-8 x4, spring washer-8 x4 and stainless steel straps x4. Wall Box Mounting Ivory, 270(L)×166(W)×95(D) (10.6×6.5×3.7 inches); 2.2 kg (4.
Installation Guide Pole Thin Direct Mounting White/Ivory, 232×136×60 mm (9.1×5.4×2.4 inches); Diameter: 112~140 mm (4.4~5.5 inches); 0.7 kg (1.6 lbs); Supplied with stainless steel straps x4, M8x16 screw x4, washer x4 and spring washer-8 x4. Pole Wide Direct Mounting White/Ivory, 270×170×60 mm (10.6×6.7×2.4 inches); Diameter: 112~130 mm (4.4~5 inches); 1 kg (2.2 lbs); Supplied with M8x16 screw x4, washer x4, stainless steel straps x4, spring washer-8 x4.
Installation Guide Other Application Accessories Repeater/Converter D77R1: RS-485/RS-422 Repeater D77R2: RS-232 between RS-485/RS-422 D77R3: Bi-phase to RS-485/RS-422 D77R1 D77R2 D77R3 Connector Box (Indoor Application) Recommended for wiring indoor dome alarm cables. White Color. 92×42 mm (3.7×1.7 inches); 0.13 kg (0.3 lbs); Supplied with cable×1, bracket×1 and M3x6 screw×2. Signal Distribution Unit Relay control codes to speed dome cameras. Dimension: 432×44×90 mm (17×17.32×35.
Installation Guide 4.3 Ceiling Mount The Dome Camera can be mounted to the concrete ceiling with the supplied Hard Ceiling Mount and optional accessory: Straight Tube. 4.3.1 Hard Ceiling Mount The indoor Dome Camera can be mounted to the concrete ceiling with the supplied Hard Ceiling Mount. The items and tools needed for hard ceiling installation are listed as follows; all the supplied items are available in the Dome Camera’s standard package.
Installation Guide STEP 1 Fasten the Fixing Plate on the Dome Camera’s back plate by first inserting the side with three holes into its mate slot on the camera’s back plate. Push the plate inside the slot to the left, aligning the three holes on the Fixing Plate to the ones on the back plate, and then screw the Fixing Plate tightly using the supplied M3 screw. NOTE: The orientation of the Fixing Plate is shown in the figure on the right side. STEP 2 Remove the Decoration Ring from the Hard Ceiling Mount.
Installation Guide STEP 5 Fix the Mount with three screws. STEP 6 Remove the Optical Cover of the Dome Camera. STEP 7 Connect the Data Cable and/or Ethernet cable through the central hole of the Mount to the Dome Camera’s corresponding connector. NOTE: If use the network Speed Dome Camera, an Ethernet cable is needed other than the Data Cable. STEP 8 Attach the Dome Camera to the Mount and rotate it clockwise. Make sure that the central part of camera bottom is locked into the central hole of the Mount.
Installation Guide STEP 9 Tighten the fixing screw of the Fixing Plate as shown in the figure. STEP10 Assemble the Decoration Ring to the Mount by pushing it up through the camera body and aligning the three pillar-like fasteners to the corresponding holes of the Decoration Ring. STEP 11 Replace the Dome Camera’s Optical Cover. The hard ceiling installation is complete.
Installation Guide 4.3.2 In-Ceiling (T-Bar) Mounting The indoor Dome Camera can be mounted with the optional accessory: In-Ceiling (T-Bar) Mount. The items and tools needed for in-ceiling installation are listed as follows.
Installation Guide STEP 2 Place the supplied Ceiling Sticker onto the ceiling, and cut the circle part (Diameter: 162 mm) out of the ceiling. STEP 3 Hold up the In-Ceiling (T-Bar) Mount and put it into the opening. STEP 4 Tighten the three fixing screws on the In-Ceiling (T-Bar) Mount as shown in the figure.
Installation Guide Figure Top view of fixed In-Ceiling (T-Bar) Mount. When screwing the In-Ceiling (T-Bar) Mount’s wing will keep approaching to the ceiling board until it is completely flush with the board. NOTE: Please make sure the In-Ceiling Mount’s wings are completely flush with the ceiling board STEP 6 Run the Data Cable through the center hole of the In-Ceiling Mount. Then Connect the cable to the mating 22-pin port on the Dome Camera’s base plate.
Installation Guide STEP 7 Mount the Dome Camera onto the In-Ceiling Mount with the exact orientation as indicated. Firstly, align the fixing screw hole on the Lock Bar with the mating slot on the ring of the In-Ceiling Mount. Then rotate the camera clockwise, and let the screw hole on the Lock Bar align with the fixing screw hole on the In-Ceiling Mount’s ring. STEP 8 Screw the Dome Camera onto the In-Ceiling Mount with the supplied M3 screw. Installation is finished. 4.3.
Installation Guide Items Needed: • Dome Camera • Data Cable (supplied) • Ethernet Cable (network Dome Camera) • Straight Tube and equipped items (optional accessory) • Indoor Mount Kit (optional accessory) • Waterproof Rubber (Indoor Mount Kit’s accessory ) • Screws and Screw Anchors for fixing the Straight Tube onto the ceiling (not supplied) Tools Needed: • Tool for drilling • Tool for screwing Follow the steps to mount the Dome Camera with the Straight Tube.
Installation Guide Ceiling Mount: Straight Tube + Indoor Mount Kit 36
Installation Guide 4.4 Wall Mount The Dome Camera can be mounted on the wall with Compact Pendent Mount, Standard Pendent Mount and Wall Box. Please follow the installation instructions below for mounting the Dome Camera via different ways. 4.4.
Installation Guide Wall Mount: Swan Tube + Indoor Mounting Kit 4.4.
Installation Guide Follow the steps below to mount the Dome Camera with the Compact Pendent Mount. 1) Make a cable entry hole on the wall to recess the cables. Otherwise, users could push up the Cable Entry Board on the Compact Pendent Mount’s Mounting Plate to place the cables, as shown in the photo below. Mounting Plate Cable Entry Board 2) Fix the Compact Pendent Mount on the wall with proper screws and screw anchors. 3) Attach the Waterproof Rubber to the Compact Pendent Mount.
Installation Guide Wall Mounting: Compact Pendent Mount + Indoor Mount Kit 4.4.
Installation Guide 1) Make a cable entry hole on the wall to recess the cables. Otherwise, users could push up the cable entry board on the Standard Pendent Mount’s mounting plate to place the cables (see the illustration in section 4.4.2 Compact Pendent Mount > Step 1). 2) Fix the Standard Pendent Mount on the wall with proper screws and screw anchors. 3) Attach the Waterproof Rubber to the Standard Pendent Mount.
Installation Guide 4.4.
Installation Guide 5) Thread the cable(s) through the Indoor Mount Kit and join the Indoor Mount Kit to the Standard/ Compact Pendent Mount with the supplied screws and washers. Then adjust the Waterproof Rubber to the joint. 6) Connect the cable(s) to the Dome Camera. 7) Join the Dome Camera to the Indoor Mount Kit with the supplied screw and washers.
Installation Guide 4.5 Corner Mount 4.5.
Installation Guide 4) Attach the Waterproof Rubber to the Standard/ Compact Pendent Mount. 5) Thread the cable(s) through the Indoor Mount Kit and join the Indoor Mount Kit to the Standard/ Compact Pendent Mount with the supplied screws and washers. Then adjust the Waterproof Rubber to the joint. 6) Connect the cable(s) to the Dome Camera. 7) Join the Dome Camera to the Indoor Mount Kit with the supplied screw and washers.
Installation Guide 4.5.
Installation Guide screws and washers. Then adjust the Waterproof Rubber to the joint. 6) Connect the cable(s) to the Dome Camera. 7) Join the Dome Camera to the Indoor Mount Kit with the supplied screw and washers.
Installation Guide 4.6 Pole Mount 4.6.
Installation Guide 4) Attach the Waterproof Rubber to the Standard/ Compact Pendent Mount. 5) Thread the cable(s) through the Indoor Mount Kit and join the Indoor Mount Kit to the Standard/ Compact Pendent Mount with the supplied screws and washers. Then adjust the Waterproof Rubber to the joint. 6) Connect the cable(s) to the Dome Camera. 7) Join the Dome Camera to the Indoor Mount Kit with the supplied screw and washers.
Installation Guide 4.6.
Installation Guide screws and washers. Then adjust the Waterproof Rubber to the joint. 6) Connect the cable(s) to the Dome Camera. 7) Join the Dome Camera to the Indoor Mount Kit with the supplied screw and washers.
Installation Guide 5. System Expansion 5.1 Connecting with Connector Box Ideally being used in indoor installation circumstances, a Connector Box provides easy wiring and well organized connection between alarms, cameras and other devices, for easy installation. To connect the connector box with other devices: • Use a RS-485 cable (CAT 5 is recommended) to complete RS-485 communication wiring with control devices such as DVRs and Control Keyboards.
Installation Guide 5.2 Data Formats Transforming To integrate other surveillance devices with the Speed Dome Cameras, we provide three kinds of converter/repeater to transform the communication formats between devices. If a converter/repeater is used, the total network distance of the surveillance system can be extended, and the connected devices will also be protected. Up to 10 devices are allowed to connect to each repeater.
Installation Guide 5.3 Signal Distribution Unit The RS-485 Signal Distribution Unit (SDU) is designed to relay control codes to Speed Dome Cameras. It is capable of communicating with cameras up to 1.0 kilometers away. Additionally, the SDU can be installed in either “star” or “daisy chain” configuration with up to 160 cameras (see the diagrams below). Its versatile installation configuration makes an easy integration into expanding surveillance systems.
Installation Guide 6. System Integration The Dome Camera is allowed to be integrated into other suppliers' surveillance systems with large set of built-in protocols. Refer to the following sections for more information. 6.1 Using Pelco Keyboard The Speed Dome Camera can be controlled through a Pelco keyboard which built in with D protocol and P protocol. Please follow the instruction to manipulate our speed dome by a keyboard with D and P protocols.
Installation Guide 6.2 Using Philips Allegiant Keyboard The Dome Cameras can be integrated into Philips Allegiant systems through D77R3 repeaters. Please follow the instructions to control Dome Cameras through Philips Allegiant systems. Symbol Definition Command dome cameras to go to a specific preset position. Set preset position. Special Function 7 6 Exit the OSD menu directly. 1. Display or hide the OSD menu. 7 7 2.
Installation Guide Appendix A: Technical Specification Item Mini Speed Dome Camera CAMERA CCD Sensor Sony CCD Optical Zoom 12x Digital Zoom 1× ~ 12× variable Effective Pixels NTSC 380k/480k PAL 440k/570k Horizontal Resolution 540 TVL/ 650 TVL Scanning System NTSC / PAL Synchronization Internal / Line Lock Video Output 1.0 Vp-p / 75 Ω, BNC Minimum Illumination 0.1 lux; 0.01 lux (B/W) Focal Length 3.8 ~ 45.
Installation Guide Item Mini Speed Dome Camera Wide Dynamic Range On / Off Day/Night: IR Cut Filter On / Off Image Freeze On / Off Image Inverse On / Off Noise Reduction 2D On / Off 3D On / Off Alarm Input 8 Alarm Output 1 Alarm Reaction Preset, Sequence, Auto pan, Cruise GENERAL Environment Indoor Controller Interface RS-485 Operating Temperature Dimension Weight Power Source 0°C ~ 40°C (32°F ~ 104°F) ∅131 x 200 mm (5.2 x 7.9 Inches) 1.2 kg (2.