POWER AMPLIFIER DPA 4120 / DPA 4140 BEDIENUNGSANLEITUNG OWNER'S MANUAL MODE D'EMPLOI DPA 4140 4 0 0 WATT S P OW E R A M PL I FI E R CLIP TEST 0dB -13dB READY STANDBY GROUND FAULT PROTECT Leistungsmerkmale Leistungsverstärker mit 200 W oder 400 W Ausgangsleistung nach IEC 283-3 19“ - Chassis (3 HE) ausgestattet mit folgenden Funktionen: x Netz-Betrieb 115/230V AC und Notstrom-Betrieb 24V DC x Endstufe DPA 4120 mit 200 W oder DPA 4140 mit 400 W Ausgangsleistung, leerlaufsicher und kurzschlußfest x Au
:,&+7,*( 6,&+(5+(,76+,1:(,6( 'DV %OLW]V\PERO LQQHUKDOE HLQHV JOHLFKVHLWLJHQ 'UHL HFNV VROO GHQ $QZHQGHU DXI QLFKW LVROLHUWH /HLWXQJHQ XQG .
Anzeigen, Bedienungselemente und Anschlüsse 1 2 DPA 4140 40 0 WATT S PO WER A MPLI FI ER TEST 3 READY STANDBY GROUND FAULT 4 PROTECT CLIP 0 dB -13 dB 5 7 6 8 A 9 10 A 11 T4A FOR 230V T8A FOR 115V POWER 12 NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
Inhaltsverzeichnis Leistungsmerkmale........................................................................................................................................ 1 Anzeigen, Bedienungselemente und Anschlüsse ......................................................................................... 3 1. Verwendung .................................................................................................................................................. 5 2. Installationshinweise ..........
1. Verwendung Die Verstärker DPA 4120 und DPA 4140 sind speziell für den leistungssicheren und zuverlässigen Betrieb von PASystemen ausgelegt. DPA 4120 und DPA 4140 sind besonders für Ruf- und Durchsageanlagen, Alarmierungsanlagen und für Musikübertragung in Betrieben, Büro- und Geschäftsräumen, Versammlungs- und Sportstätten, Schulen und Kirchen, Hotels, Krankenhäusern, Supermärkten, Fahrgastschiffen und andere ähnliche Anwendungen geeignet. 2.
Bei richtigem Anschluß und vorhandener Netz-Spannung leuchtet die grüne STANDBY Anzeige (4). Zum Einschalten des Verstärkers bei Netzbetrieb mit Ferneinschaltung ist an der Stiftleiste REMOTE CONTROL (16) Kontakt 3 POWER REMOTE mit Kontakt 2 - GROUND STANDBY zu verbinden (siehe Abschnitt 5.6). Für Servicezwecke ist der Netz-Funktionsschalter POWER (9) an der Geräterückseite vorgesehen, mit dem das Netz-Einschaltrelais überbrückt werden kann.
Bild 2 NF-Verbindungskabel zur Koppelung von zwei Verstärkern DPA 41xx 5. Ausgänge 5.1 Leistungsausgang POWER OUTPUT Der Leistungsausgang ist symmetrisch, erdfrei. Der Ausgang ist ab Werk für den Anschluß von 100VLautsprechern vorgesehen. Der Anschluß erfolgt über den mitgelieferten 5-poligen Stecker an der Buchsenleiste (17). Eine Umstellung der Ausgangsspannung auf 70V, 50V oder niederohmigen Betrieb (4 Ohm) kann durch die Steckbrücke B411 auf Printplatte 84187 (DPA 4120) bzw.
5.4 Leistungsausgang POWER OUTPUT für niederohmige Lautsprecher Bei Umschaltung des Ausgangs auf 4 Ohm können niederohmige Lautsprecher (4-16 Ohm) angeschlossen werden (siehe Abschnitt 7 und Bild 3). Wegen der Leitungsverluste soll die Entfernung zwischen Verstärker und Lautsprecher jedoch nicht mehr als etwa 50m betragen. Es ist darauf zu achten, daß die gesamte Lautsprecher-Impedanz von 4 Ohm nicht unterschritten wird und die für den einzelnen Lautsprecher angegebene Leistung nicht überschritten wird.
6.3 PROTECT Anzeige Bei Übertemperatur im Netztransformator oder in der Endstufe leuchtet die rote PROTECT Anzeige (5) und das READY-Störungsmelde-Relais schaltet in Ruhelage. Nach Abkühlung des Verstärkers erlischt die rote PROTECT Anzeige (5) automatisch und das Gerät schaltet in den Normalbetrieb. Die Ursache dieses Fehlerzustandes kann Überlast, zu hohe Umgebungstemperatur oder ein Fehler im Lüftungssystem sein. 6.
Vorsicht Die Ausgänge an der Anschlußbuchse POWER OUTPUT können im Betrieb berührungsgefährliche Werte annehmen (>34V Spitzenwert). Die angeschlossenen Lautsprecherkreise sind aus diesem Grunde gemäß den geltenden Sicherheitsbestimmungen zu installieren (siehe auch Abschnitt 8.5.2). 8. Erweiterung des Anwendungsbereiches 8.
x x x x Monitoring: Input- / Outputsignal auf Monitorbus schalten Eingangsübertrager für erdfrei, symmetrischen Eingang (optional) Ausgangsübertrager für erdfrei, symmetrischen Monitor-Ausgang (optional) Pilottonsignal ON/OFF (optional) Das Remote Modul dient als Fernsteuer-Einschub für die Endstufen DPA 4120 und DPA 4140. Damit können diese Endstufen vom PROMATRIX Manager DPM 4000 gesteuert und überwacht werden (siehe PROMATRIX Handbuch).
Input Transformer NRS 90208 Output Transformer NRS 90227 Bild 6 Printplatte 81338 mit Lage des Eingangsübertragers NRS 90208 und des Ausgangsübertragers NRS 90 227 Input Transformer NRS 90208 Output Transformer 90 227 Bild 7 Printplatte 81339 mit Lage des Eingangsübertragers NRS 90208 und des Ausgangsübertragers NRS 90 227 12
8.5 Pilotton & Erdschluß Überwachung NRS 90224 Der Nachrüstsatz NRS 90224 ist steckbar und besteht aus einem 19 kHz-Generator und einem selektiven 19 kHzEmpfänger mit Auswertestufe für die Pilotton-Überwachung sowie einer Überwachungsschaltung für die an den Ausgang angeschlossenen Leitungen mit Fehlerspeicher und Anzeigetreiber. 8.5.1 Pilotton-Überwachung: Bei Verwendung des Nachrüstsatzes NRS 90224 findet eine kontinuierliche Selbstüberwachung des Verstärkers statt.
NRS 90 224 S 406 S 405 B 411 Bild 8 Printplatte 84187 in DPA 4120 mit Lage des NRS 90224 Pilotton & Erdschluß Überwachung, der Steckbrücke B411 und S405, S406 zur Ausgangsspannungs-Umschaltung 14
NRS 90 224 S 406 S 405 B 411 Bild 9 Printplatte 84175 in DPA 4140 mit Lage des NRS 90224 Pilotton & Erdschluß Überwachung, der Steckbrücke B411 und S405, S406 zur Ausgangsspannungs-Umschaltung Prüfung der Funktion Pilotton-Überwachung: Bei eingebautem NRS 90224 und eingeschaltetem Verstärker muss die grüne READY-Betriebsanzeige (7) leuchten. Zur Funktionskontrolle der Pilotton-Überwachung dient die Prüf- und Reset-Taste TEST (3).
Prüfung der Funktion Erdschluß-Überwachung: Bei eingebautem NRS 90224 und eingeschaltetem Verstärker muss die grüne READY-Betriebsanzeige (7) leuchten. Schaltet man mit Hilfe einer externen Taste einen 47kOhm Widerstand ca. 5 sek lang von einem Pol des 100V-Lautsprechernetzes gegen Schutzerde, muß die entsprechende rote GROUND FAULT Anzeige (6) aufleuchten und das READY-Störungsmelde-Relais des INPUT MODUL NRS 90225 schaltet in Ruhelage, die grüne READY-Betriebsanzeige (7) bleibt erhalten.
F 503 F 502 Bild 10 Printplatte 85270 in DPA 4120 mit Lage der DC Sicherungen F502 und F503 17
F 503 F 502 Bild 11 Printplatte 85268 in DPA 4140 mit Lage der DC Sicherungen F502 und F503 18
F 601 F 602 Bild 12 Printplatte 86243 DPA 4120 und DPA 4140 mit Lage der AC Sicherungen F601 und F602 Vorsicht Vor dem Öffnen des Gerätes ist der Netzstecker zu ziehen und eventuell angeschlossene Batterieleitungen sind abzustecken ! Auswechseln der Sicherungen F502 und F503 (Nur vom Fachmann auszuführen!) Die Batteriesicherungen F502 und F503 befinden sich auf der Netzteil-Printplatte 85270 (DPA 4120) bzw. 85268 (DPA 4140) hinter den AMP-Batterie-Anschlüssen (siehe Bild 10 bzw. Bild 11).
12. Technische Daten 12.1 DPA 4120 Leistungsverstärker 200 W Stromversorgung: Netzbetrieb Netzfrequenz Schutzklasse 115 V / 230 V~ AC, r10 % 50 - 60 Hz , Netzbetrieb Leerlauf Normalbetrieb (-10 dB) Alarm (-3 dB) Nennbedingungen Netz-Einschaltstoßstrom Netzbetrieb Leerlauf Normalbetrieb (-10 dB) Alarm (-3 dB) Nennbedingungen Netz-Einschaltstoßstrom Unetz / V Inetz / A Pnetz / VA Pnetz / W Pout / W Pv / W 230 230 230 230 0.13 0.83 1.67 2.
12.2 DPA 4140 Leistungsverstärker 400 W Stromversorgung: Netzbetrieb Netzfrequenz Schutzklasse 115 V / 230 V~ AC, r10 % 50 - 60 Hz , Netzbetrieb Leerlauf Normalbetrieb (-10 dB) Alarm (-3 dB) Nennbedingungen Netz-Einschaltstoßstrom Netzbetrieb Leerlauf Normalbetrieb (-10 dB) Alarm (-3 dB) Nennbedingungen Netz-Einschaltstoßstrom Unetz / V Inetz / A Pnetz / VA Pnetz / W Pout / W Pv / W 230 230 230 230 0.19 1.60 3.10 4.
13. Technische Daten der Nachrüstsätze für den Verstärker DPA 4120 / DPA 4140 13.1 NRS 90225 Standard Eingangsmodul siehe technische Daten DPA 4120 / DPA 4140 13.2 NRS 90222 Remote Modul siehe technische Daten DPA 4120 / DPA 4140 13.3 NRS 90208 Eingangs-Übertrager für erdfrei, symmetrischen Eingang Übertragungsbereich Eingangsimpedanz Leerlauf-Übersetzungsverhältnis Wicklungswiderstand primär Wicklungswiderstand sekundär 13.4 20 Hz ..
POWER AMPLIFIER DPA 4120 / DPA 4140 OWNER'S MANUAL DPA 4140 4 0 0 WATT S P OW E R A M PL I FI E R CLIP TEST 0dB -13dB READY STANDBY GROUND FAULT PROTECT Performance Features Power amplifier with 200 W or 400 W output power according to the IEC 283-3 standard within a 19“ - cabinet (3 HU) providing the following functions: x supported are 115/230V AC mains as well as 24V DC emergency power source x power amplifiers DPA 4120 providing 200 W or DPA 4140 providing 400 W output power, idling and short-c
,03257$17 6$)(7< ,16758&7,216 7KH OLJKWQLQJ ÀDVK ZLWK DUURZKHDG V\PERO ZLWKLQ DQ HTXLODWHUDO WULDQJOH LV LQWHQGHG WR DOHUW WKH XVHU WR WKH SUHVHQFH RI XQLQVXODWHG ÄGDQJHURXV YROWDJH³ ZLWKLQ WKH SURGXFW¶V HQFORVXUH WKDW PD\ EH RI VXI¿FLHQW PDJQLWXGH WR FRQVWLWXWH D ULVN RI HOHFWULF VKRFN WR SHUVRQV 7KH H[FODPDWLRQ SRLQW ZLWKLQ DQ HTXLODWHUDO WULDQJOH LV LQWHQGHG WR DOHUW WKH XVHU WR WKH SUHVHQFH RI LPSRUWDQW RSHUDWLQJ DQG PDLQWDQFH VHUYLFLQJ LQVWUXFWLRQV LQ WKH OLWHUDWXUH DFFRPSDQ\
Indicators, controls and connections 1 2 DPA 4140 400 WATT S PO WER A MPLI FI ER TEST 3 READY STANDBY GROUND FAULT 4 PROTECT CLIP 0 dB -13 dB 5 7 6 8 A 9 10 A 11 T4A FOR 230V T8A FOR 115V POWER 12 NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
Contents Performance Features ................................................................................................................................. 23 Indicators, controls and connections ........................................................................................................... 25 1. Utilization ..................................................................................................................................................... 27 2. Installation ..............
1. Utilization The amplifiers DPA 4120 and DPA 4140 are specially designed for the power-consistent and reliable operation of PA-systems. The DPA 4120 and DPA 4140 are intended to be used in company intercom, alarm and background music transmission installations, offices and commercial areas, congregation and sport centers, schools, churches, hotels, hospitals, shopping malls and super markets, cruise ships, and other similar applications. 2.
If the appliance is correctly connected and mains is present the green STANDBY indicator (4) will light. To remotely start the amplifier when it is being operated on the mains, it is necessary to interconnect the contacts 3 - POWER REMOTE and 2 - GROUND STANDBY on the pin terminal strip REMOTE CONTROL (16) (see also paragraph 5.6). The main power switch POWER (9) on the rear of the appliance is meant for service and maintenance purposes.
figure 2 LF cable for coupling two amplifiers DPA 41xx 5. Outputs 5.1 POWER OUTPUT The power output is balanced and off-ground potential. The output is factory-configured for the connection of 100V loudspeaker systems. Connection has to be performed by inserting the supplied 5-pole plug into the power output socket (17).
5.5 MONITOR output The MONITOR output (16) on the NRS 90225 allows the connection of an additional power amplifier for monitoring purposes. The low impedance output is electronically balanced, which offers the possibility to achieve cable lengths of up to 200 m. Connection is performed via the REMOTE CONTROL pin-connector strip (see also figure 4). For the remote control module NRS 90222, the MONITOR output is located on the REMOTE CONTROL connector (22).
6.5 Level meter and CLIP indicator The green LED-indicators -13dB and 0dB (1) together with the red CLIP-LED (2) allow to monitor the output level, effectively avoiding overdrive conditions that lead to distortion and overload at the power outputs which could damage the connected loudspeaker systems. - If the red CLIP-LED (2) shortly lights during program peaks, maximum non-distorted modulation is achieved. - Continuous lighting or blinking of the red CLIP-LED (2) signals overdrive.
8. Enhanced application field 8.1 Standard input module NRS 90225 This input module for the power amplifiers DPA 4120 and DPA 4140 is meant for insertion at the power amplifiers' rear.
The remote module allows to remotely control and monitor the operation of the power amplifiers DPA 4120 and DPA 4140 from the PROMATRIX manager DPM 4000 (for further details please refer to the PROMATRIX handbook). Caution: Before installing the input module NRS 90222, you have to unplug the mains connector as well as a presumably connected battery cord. Before installing the input module, it is necessary to remove the two locking screws B on the rear panel of the appliance.
Input Transformer NRS 90208 Output Transformer NRS 90227 figure 6 printed board assembly 81338 showing the input transformer NRS 90208 and the output transformer NRS 90 227 Input Transformer NRS 90208 Output Transformer 90 227 figure 7 printed board assembly 81339 showing the input transformer NRS 90208 and the output transformer NRS 90 227 34
8.5 NRS 90224 pilot tone & ground fault surveillance The extension NRS 90224 is meant for insertion. It includes a 19 kHz tone generator and a selective 19 kHz receiver with evaluation stage for pilot tone surveillance. Also incorporated is a monitoring circuit with fault storage and display driver, to guard the cable network connected to the output. 8.5.1 Pilot tone surveillance: Integration of the extension NRS 90224 provides continuous self-monitoring of the amplifier.
NRS 90 224 S 406 S 405 B 411 figure 8 printed board assembly 84187 in the DPA 4120 showing the NRS 90224 pilot tone & ground fault surveillance and the bridges B411 and S405, S406 for switching the output voltage; inserted 36
NRS 90 224 S 406 S 405 B 411 figure 9 printed board assembly 84175 in the DPA 4140 showing the NRS 90224 pilot tone & ground fault surveillance and the bridges B411 and S405, S406 for switching the output voltage; inserted Checking the pilot tone surveillance function: When the NRS 90224 is installed and the power amplifier is switched on, the green READY indicator (7) has to light. The testing and reset button TEST (3) serves as a function control for the pilot tone surveillance.
Checking the ground fault surveillance function: When the NRS 90224 is installed and the power amplifier is switched on, the green READY indicator (7) has to light. Utilizing an external switch to connect one pole of the 100V-loudspeaker network via a 47 k ohms resistor for approximately 5 seconds to ground potential, the corresponding red GROUND FAULT indicator (6) has to light and the READY fault message relay of the INPUT MODULE NRS 90225 drops while the green READY indicator (7) stays lit.
F 503 F 502 figure 10 printed board assembly 85270 in the DPA 4120 showing the DC fuses F502 and F503 39
F 503 F 502 figure 11 printed board assembly 85268 in the DPA 4140 showing the DC fuses F502 and F503 40
F 601 F 602 figure 12 printed board assemblies 86243 DPA 4120 and DPA 4140 showing the AC fuses F601 and F602 Caution Before opening the appliance, make sure to disconnect the mains and/or battery power source! Replacing the fuses F502 and F503 (only to be carried out by the experienced service technician!) The battery fuses F502 and F503 are located on the power supply PCBs 85270 (DPA 4120) and 85268 (DPA 4140) behind the AMP battery connectors (see also figure 10 and/or figure 11).
12. Specifications 12.1 DPA 4120 power amplifier 200 W power supply: mains operation mains frequency security class 115 V / 230 V~ AC, ±10 % 50 - 60 Hz I mains operation idling normal operation (-10 dB) alarm (-3 dB) standard conditions initial current inrush (mains) Umains / V Imains / A Pmains / VA Pmains / W Pout / W Pv / W 230 230 230 230 0.13 0.83 1.67 2.
12.2 DPA 4140 power amplifier 400 W power supply: mains operation mains frequency security class 115 V / 230 V~ AC, r10 % 50 - 60 Hz I mains operation idling normal operation (-10 dB) alarm (-3 dB) standard conditions initial current inrush (mains) Umains / V Imains / A Pmains / VA Pmains / W Pout / W Pv / W 230 230 230 230 0.19 1.60 3.10 4.
13. Extension kit specifications for the power amplifiers DPA 4120 / DPA 4140 13.1 NRS 90225 standard input module see specifications DPA 4120 / DPA 4140 13.2 NRS 90222 remote module see specifications DPA 4120 / DPA 4140 13.3 NRS 90208 input transformer for floating, balanced input frequency response 20 Hz .. 20 kHz input impedance t 10 k ohms idling ratio 1:1 winding resistance; primary 1420 ohms at 20°C winding resistance; secondary 1420 ohms at 20°C 13.
AMPLIFICATEUR DE PUISSANCE DPA 4120 / DPA 4140 MODE D'EMPLOI DPA 4140 4 0 0 WATT S P OW E R A M PL I FI E R CLIP TEST 0dB -13dB READY STANDBY GROUND FAULT PROTECT Caractéristiques techniques Amplificateur de puissance restituant 200 W ou 400 W en sortie, selon le standard IEC 283-3 en rack 19“ - (3 U) et disposant des fonctions suivantes : x alimentation secteur en 115/230V AC ainsi qu'en 24V DC comme alimentation de secours x les amplificateurs DPA 4120 ont une puissance de 200 W en sortie ou de 4
,16758&7,216 '( 6e&85,7e ,03257$17(6 /H V\PEROH UHSUpVHQWDQW XQ pFODLU ÀpFKp GDQV XQ WULDQJOH pTXLODWpUDO D SRXU EXW G¶DOHUWHU O¶XWLOLVDWHXU GH OD SUpVHQFH G¶XQH ÄWHQVLRQ GDQJHUHXVH³ QRQ LVROpH j O¶LQWpULHXU GX ERvWLHU SRXYDQW rWUH G¶XQH IRUFH VXI¿VDQWH SRXU FRQVWLWXHU XQ ULVTXH G¶pOHFWURFXWLRQ /H SRLQW G¶H[FODPDWLRQ GDQV XQ WULDQJOH pTXLODWpUDO D SRXU EXW G¶DOHUWHU O¶XWLOLVDWHXU GH OD SUpVHQFH G¶LQVWUXFWLRQV LPSRUWDQWHV FRQFHUQDQW OH IRQFWLRQQHPHQW HW OD PDLQWHQDQFH GDQV OD GRFXPHQWDWLRQ TXL DFF
Témoins, contrôles et connexions 1 2 DPA 4140 400 WATTS P OW ER A MPL I FI ER TEST 3 READY STANDBY GROUND FAULT 4 PROTECT CLIP 0 dB -13 dB 5 7 6 8 A 9 10 A 11 T4A FOR 230V T8A FOR 115V POWER 12 NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
Table des matières Caractéristiques techniques......................................................................................................................... 45 Témoins, contrôles et connexions ............................................................................................................... 47 1. Utilisation...................................................................................................................................................... 49 2. Installation ......
1. Utilisation Les amplificateurs DPA 4120 et DPA 4140 ont été conçus plus particulièrement pour les sonorisations fixes demandant une certaine fiabilité.
Si l'appareil est correctement connecté et que du courant arrive, le témoin vert STANDBY (4) doit s'allumer. Pour démarrer l'amplificateur à distance lorsqu'il fonctionne sur le secteur, il est nécessaire d'interconnecter les contacts 3 - POWER REMOTE et 2 - GROUND STANDBY au connecteur REMOTE CONTROL (16) (voir aussi le paragraphe 5.6).
figure 2 Câblage LF pour le couplage de deux amplificateurs DPA 41xx 5. Sorties 5.1 POWER OUTPUT La sortie de puissance est symétrisée et non référencée à la masse. En usine cette sortie est configurée pour la connexion de systèmes de haut-parleurs 100V. La connexion doit être effectuée en insérant la prise 5 fiches fournie dans l'embase de sortie de puissance (17).
parleurs ne soit pas inférieure à une valeur de 4 ohms et que la capacité de puissance d'un seul haut-parleur ne soit pas dépassée. 5.5 Sortie MONITOR La sortie MONITOR (16) sur le module NRS 90225 permet la connexion d'un autre amplificateur de puissance pour le monitoring. La sortie basse impédance est symétrisée électroniquement, ce qui offre la possibilité d'avoir des longueurs de câbles allant jusqu'à 200 m. La connexion s'effectue via le connecteur REMOTE CONTROL (voir aussi la figure 4).
6.4 Témoin GROUND FAULT Si, alors que l'extension NRS 90224 est installée, un défaut de masse a été détecté à la sortie de puissance, le témoin rouge GROUND FAULT (6) s'allume et le relais de message d'alerte READY se ferme. Lorsque se produit ce type d'erreur, le fonctionnement normal est maintenu. Après avoir éliminer la cause du défaut de masse, appuyer sur le bouton TEST (3) réinitialisera le témoin GROUND FAULT (6) (voir aussi le paragraphe 8.5.2). 6.
8. Champs d'applications avancées 8.1 Module d'entrée standard NRS 90225 Ce module d'entrée pour amplificateurs de puissance DPA 4120 et DPA 4140 est conçu pour être inséré à l'arrière des amplificateurs.
Le module de télécommande permet de contrôler à distance et d'écouter le fonctionnement des amplificateurs de puissance DPA 4120 et DPA 4140 à partir du PROMATRIX Manager DPM 4000 (pour de plus amples renseignements, reportez-vous au livret PROMATRIX). Attention : Avant d’installer le module d’entrée NRS 90222, vous devez débrancher le connecteur secteur ainsi que le cordon éventuellement connecté à la batterie.
Input Transformer NRS 90208 Output Transformer NRS 90227 figure 6 Circuit imprimé 81338 avec transformateur d'entrée NRS 90208 et transformateur de sortie NRS 90 227 Input Transformer NRS 90208 Output Transformer 90 227 figure 7 Circuit imprimé 81339 avec transformateur d'entrée NRS 90208 et transformateur de sortie NRS 90 227 56
8.5 Surveillance de la fréquence pilote et du défaut de masse NRS 90224 L'extension NRS 90224 est prévue pour être insérée. Elle comprend un générateur de fréquence 19 kHz et un récepteur sélectif 19 kHz avec étage d'évaluation pour la surveillance de la fréquence pilote. Elle comprend également un circuit de monitoring avec mémorisation des erreurs et driver d'affichage, pour surveiller le réseau de câbles connectés à la sortie. 8.5.
NRS 90 224 S 406 S 405 B 411 figure 8 Circuit imprimé 84187 dans le DPA 4120 avec insertion de l'extension Surveillance de la fréquence pilote & du défaut de masse NRS 90224 ainsi que des ponts B411 et S405, S406 pour sélection de la tension de sortie 58
NRS 90 224 S 406 S 405 B 411 figure 9 circuit imprimé 84175 dans le DPA 4140 avec insertion de l'extension Surveillance de la fréquence pilote & du défaut de masse NRS 90224 ainsi que des ponts B411 et S405, S406 pour sélection de la tension de sortie Vérification de la fonction de surveillance de la fréquence pilote : Lorsque l'extension NRS 90224 a été installée et que l'amplificateur de puissance est sous tension, le témoin vert READY (7) doit s'allumer.
Vérification de la fonction de surveillance du défaut de masse : Lorsque l'extension NRS 90224 a été installée et que l'amplificateur de puissance est sous tension, le témoin vert READY (7) doit s'allumer.
F 503 F 502 figure 10 Circuit imprimé 85270 dans le DPA 4120 avec fusibles DC F502 et F503 61
F 503 F 502 figure 11 Circuit imprimé 85268 dans le DPA 4140 avec fusibles DC F502 et F503 62
F 601 F 602 figure 12 Circuit imprimé 86243 dans les DPA 4120 et DPA 4140 avec fusibles AC F601 et F602 Attention Avant d'ouvrir l'appareil veillez à le déconnecter du secteur et/ou de la batterie ! Remplacement des fusibles F502 et F503 (ne peut être effectué que par un technicien expérimenté !) Les fusibles de batterie F502 et F503 sont situés dans l'alimentation PCBs 85270 (DPA 4120) et 85268 (DPA 4140) derrière les connecteurs de batterie AMP (voir également la figure 10 et/ou la figure 11).
12. Caractéristiques 12.
12.
13. Caractéristiques des kits d'extension pour amplificateurs de puissance DPA 4120 / DPA 4140 13.1 NRS 90225 module d'entrée standard voir caractéristiques des DPA 4120 / DPA 4140 13.2 NRS 90222 module de télécommande voir caractéristiques des DPA 4120 / DPA 4140 13.3 NRS 90208 transformateur d'entrée pour entrée flottante symétrisée réponse en fréquence 20 Hz ..
ISSUE REVISION DATE NAME OPTIONS: AMP OUTPUT SIGNAL PILOT SIGNAL AMP INPUT SIGNAL 1998 DATE NAME DSG'D 20.04. Halswick CHK'D 20.04. Halswick APP'D EVI AUDIO DYNACORD 68 354 573 INPUT MODULE NRS 90225 NOTE 2: NRS 90227 OUTPUT TRANSFORMER NOTE 1: NRS 90208 INPUT TRANSFORMER GROUND GROUND READY RELAY E-RELAY E-RELAY READY D-RELAY D-RELAY BATT. POWER ON/OFF LEVEL BATT. POWER ON/OFF NOTE 2 NOTE 1 MAINS POWER ON/OFF MONITOR THRU BAL.
Bosch Communications Systems Americas–Headquarter Americas Telex Communications, Inc.