User Manual

17
NI-CD SENSITIVITY D. PEAK – DEFAULT
The D.Peak (Delta Peak) value is adjustable between 3mV/Cell and 15mV/
Cell. 10mV/Cell is a good starting point for Ni-Cd batteries. If the Delta Peak
value is too high, you risk overcharging the battery; if the value is too low,
charging will stop before the battery reaches full capacity.
KEY BEEP (DEFAULT ON) / BUZZER (DEFAULT ON)
Use the Key Beep/Buzzer menu to set the key beep and charger alarm buzzer
at ON or OFF as needed. We recommend that you leave the alarm ON to
alert you when charging is complete or if there is cause for alarm during
charging.
DC INPUT LOW
Defi nes the minimum voltage the charger will operate at when using a DC
power supply.
BALANCE CONNECTION (DEFAULT ON)
When the Balance connection is on the charger will require a balance
connection for Li-XX batteries and will confi m the batteries are within safe
limits or the charger will not start the charge process.
AC MAX POWER
Prset this value to limit the AC power draw, which can be helpful for
powering from a generator or inverter.
LOAD FACTORY SETTINGS PRESS ENTER > 2S
Press the ENTER / Start button for more than 2 seconds to reset all charger
values to the default values.
HARDWARE AND FIRMWARE SETTINGS
Select this option to view the Hardware and Firmware version numbers
NiCd Sensitivity
D.Peak 4mV
Key Beep ON
Buzzer ON
Bal. Connection
ON
AC MAX POWER
100W
Load Factory Set
Enter
VERSION
HW: FW:
DC INPUT LOW
10.0V