5. Mounting
10
The mounting method is one of the most critical factors for
measuring vibration. A rigid attachment is essential for avoiding
false readings and data.
Depending on the type of machine and position, different
mounting methods could be used. To get the best results from the
DynaPredict solution, screw mounting is recommended. To do this,
the installation surface must be prepared first, as described below.
Screw Mounting
Before choosing this mounting method, check that the instal-
lation point on the equipment is thick enough for drilling. If so,
follow the step-by-step procedure below
Drilling the Machine
Drill a threaded hole with an M6x1 threaded tap (supplied in
kits with 21 DynaLoggers) at the point of measurement, at least
15mm deep.
Cleaning
Using a wire brush or fine sandpaper, clean any solid particles
and scale on the surface of the measurement point.
After surface preparation, the DynaLogger attachment pro-
cess should begin.
DynaLogger mounting
Position the DynaLogger at the measurement point so that
the base of the device is completely supported by the installation