Figure: DynaLogger installation with glue fixation
For these cases, in addition to the traditional surface prepara-
tion described above, chemical cleaning must also be carried out
on site.
Chemical cleaning
Using an appropriate solvent, remove any oil or grease resi-
due that may be at the installation site.
After surface preparation, the glue preparation process
should begin.
Preparation of the Adhesive
The most suitable adhesives for this type of fixation, according
to tests conducted by Dynamox, are the Scotch Weld DP-8810 or
DP-8405 structural adhesives from 3M. Follow the preparation
instructions described in the manual of the adhesive itself.
Dynalogger Mounting
Apply the glue so that it covers the DynaLogger’s entire
bottom surface, completely filling the center hole. Apply the glue
from the middle to the edges.