Quick Start Guide

DynaPredict Manual - Quick Start - Version 3 – September 2022
Public Document
09
Figure: Axes orientation
Left: DynaLogger TcA+. Right: DynaLoggers HF and HF+
The images above show the orientation of the DynaLogger
axes. This can also be seen on the label attached to the devices. The
correct positioning of the device should take into account the axis
and orientation of the machine.
1. The DynaLogger must be installed in a rigid part of the ma-
chine, avoiding regions that may present localized resonance;
2. Preferably, the DynaLogger should be centered in relation
to critical components, such as bearings;
3. It is recommended to keep the DynaLogger at a fixed point,
i.e., to define a definite installation for each device in order to
obtain repeatability in measurements and a history of quality data;
4. It is recommended to verify that the surface temperature of
the monitoring point is within the recommended limits (-10ºC to
84ºC) for the use of DynaLoggers. Using the DynaLoggers at tem-
peratures outside the specified range will void the product warran-
ty;
Regarding the actual installation locations, we have created a
suggestion guide for the most common machine types. This guide
can be found on our Support page (https://support.dynamox.net),
in the section “Applications and good monitoring practices”.