8.4.- ALARM FUNCTION: 
Hold down the programmed side key with this function, the transceiver will sound alarm tone and 
send “ANI” identification code to others transceiver of their group. 
8.5.- EMERGENCY CHANNEL: 
Press the [#T-R] key, in any case the transceiver can call up the emergency call 
channel, and the display shows “CAL”. 
8.6.- REVERSE FREQUENCY FUNCTION: 
This  function is  possible  only  when you  are  linked  to  a repeater.  It  permits to  invert  the  TX 
frequency with the RX frequency. 
In channel/frequency mode, hold down the [#T-R] key for two seconds until “T*R” 
appears on the display. 
The  display  shows  the  “REV”  icon.    Repeat  the  same  procedure  to  return  to  the  normal  mode 
operation. 
8.7.- SCANNING: 
The scan function is very useful to monitor the channels before transmitting. 
1.- Scan channels or frequency: 
In channel/frequency mode, press the [MENU] + [1SCAN] key, and then press the [ENTER] key to 
start the scan from the channel or frequency in use. Whenever any signal is detected, the transceiver 
will suspend the scan for 5 seconds. The transceiver will then continue to scan unless you press the 
[PTT] or [ENTER] key to end scanning. 
2.- Priority channel scan: 
Priority scan is to scan the priority channel firstly and then scan other channel, if you set priority 
channel 1, it will scan 1-2; 1-3; 1-4; and continue.  In channel mode, press the [MENU] + [2PRI] 
key, and then press the [ENTER] key to  scan the  priority channel.  The  transceiver  begin to scan 
priority channel. When any signal is detected, the transceiver will suspend the scan for 5 seconds. It 
will then continue to scan unless you press the [PTT] or [ENTER] key to end scanning. 
3.- Subtone scan: 
 In the frequency mode, press the [MENU] key and rotary the selector knob to select the “021 CTC 
• S?” menu  or the  “022 DCS.S?” menu.  Then  press the [ENTER]  key to  enter the  “CTCSS”  (50 
groups) scan or “DCS” (105 groups). When the transceiver scan to the same subtone or code, open 
the “Squelch” and exit scan. 
8.8.- SELECT SCAN TYPE: 
Press the [MENU] key and rotate the selector knob until the display shows “013 SCANS”. Press the 
[ENTER] key and turn the selector knob again to select the scan type “TO/CO/SE”. 
-  TO:  Even  though  the transceiver  stops  on  a  busy  channel  or frequency  and it  will  continue 
scanning the other channels or frequency. 
- CO: The transceiver stops on a busy channel or frequency until there is no activity, and then the 
transceiver begins scanning the other channels. 
Παύλος Μεϊµάρης Ελπίδος 34 (ΒΑΟ) Συκιές, Θεσσαλονίκη τηλ 2310.634.513, 6977.38.38.73 
URL: 
http://www.meimaris.com -
Εmail: info@meimaris.com
Παύλος Μεϊµάρης Ελπίδος 34 (ΒΑΟ) Συκιές, Θεσσαλονίκη τηλ 2310.634.513, 6977.38.38.73 
URL: 
http://www.meimaris.com -
Εmail: info@meimaris.com