Hybrid Ultrasonic DXN Portable Ultrasonic Measurement System ® Badger Meter HYB-PM-00095-EN-02 (May 2013) Firmware Update Manual
DXN Portable Ultrasonic Measurement System Page ii May 2013
Firmware Update Manual CONTENTS UPGRADING SOFTWARE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 QUICK BOOT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
DXN Portable Ultrasonic Measurement System UPGRADING SOFTWARE IIMPORTAN The Dynasonics USB Update Drive is formatted in FAT/FAT32. NTFS (New Technology File System) formats do not work. The upgrade is supplied as a self extracting zip file that you must extract on a PC before it can be loaded into the DXN. 1. Save the supplied zip file to a convenient place on your computer’s hard drive. 2. Double-click on the PortableFlowmeter_YYYYMMDD_RevX.zip file to start the extraction process.
Firmware Update Manual 5. Insert the USB Update Drive into the USB port on the rear of the DXN and wait 30 seconds for the DXN to recognize the USB Update Drive. 6. From the Display ► Meters screen, press the System tab on the far right of the display. 7. From the System screen, select Update (System ► Update). Display Misc Site Meter Power Disk Log I/O ENet Storage PC Adv Time Cal Update System Comm Quit Meter to Manage / Update GUI -> Rev H = V 001.16 20121205.
DXN Portable Ultrasonic Measurement System Launch Updater Series DXN Rev G Start Flowmeter Start Updater Flowmeter Administration Tools 800-535-3569 dynasonics.com ©2012 Racine Federated Inc., all rights reserved 10. Press the Unlock button (Step 1: Unlock System (Reboot).
Firmware Update Manual Check Update Status Restart System Unlock Step 1: Unlock System (Reboot) Update System Step 2: Update System (Reboot) × Reboot Step 3: Copy Updated Files OK Copy Update Flowmeter Step 4: Update Flowmeter Quit Update Utility UD: XKey1 exists UD: SR value is 0 UD: Eth Services IP=192.168.0.100 Subnet = 255.255.255.
DXN Portable Ultrasonic Measurement System 12. Insert the USB Update Drive. When the USB Update Drive containing the update is inserted the grayed out button changes to an active Start Updater button. Launch Updater Series DXN Rev G Start Flowmeter Start Updater Flowmeter Administration Tools 800-535-3569 dynasonics.com ©2012 Racine Federated Inc., all rights reserved 13. Press the Start Updater button. 14. The meter should now be back on the Update screen.
Firmware Update Manual Check Update Status Restart System Unlock Step 1: Unlock System (Reboot) Update System Step 2: Update System (Reboot) × Reboot Step 3: Copy Updated Files OK Copy Update Flowmeter Step 4: Update Flowmeter SET: SET: SET: SET: SET: SET: SET: SET: SET: OK: OK: OK: OK: SET: SET: OK: SET: SET: SET: SET: SET: Quit Update Utility D:\WindowsD\WMILogs D:\WindowsD\MSMQLogs HKEY_CURRENT_USER\Software\Microsoft HKEY_CURRENT_USER\Software\Microsoft HKEY_CURRENT_USER\Envrioment fro HKEY
DXN Portable Ultrasonic Measurement System Check Update Status Restart System Quit Update Utility Copy Files Complete 98 Files Unlock Step 1: Unlock System (Reboot) Update System Step 2: Update System (Reboot) Copy Step 3: Copy Updated Files Update Flowmeter Step 4: Update Flowmeter Step 5: Lock System (Reboot) Lock ORDE M & PRO GR ES S 800-535-3569 O dynasonics.com ©2012 Racine Federated Inc., all rights reserved 18. Press the Update Flowmeter button (Step 4: Update Flowmeter).
Firmware Update Manual Check Update Status Restart System Unlock Step 1: Unlock System (Reboot) Update System Step 2: Update System (Reboot) Copy Step 3: Copy Updated Files Update Flowmeter Step 4: Update Flowmeter Lock 15:19:23 Begin Embedded Update 15:19:23 Boot...AAAtrtrtrtr TrRBB Ready 15:19:28 Embedded File: CRC32B: 18C97728 MD5: 867B861C 7038 D7D4 A2C5 F74EE8D207CE 15:19:30 Erase ............ Success 15:19:41 Program ............ Success 15:20:11 Verify ............
DXN Portable Ultrasonic Measurement System Normal Start APP Series DXN Start Flowmeter Insert USB Update Drive Flowmeter Administration Tools 800-535-3569 dynasonics.com ©2012 Racine Federated Inc., all rights reserved 21. Press the Start Flowmeter button to begin normal operations. NNOTE: If the USB Update Drive is not removed before the OK button is pressed, the unit may lock-up. The error message ”Lock EWF Fail” may also appear in the text area. Remove the USB Update Drive.
Firmware Update Manual This condition requires a hard reboot by pressing and holding the main power button until the unit turns off. When the power button is pressed again the meter should start normally. A successful update is verified by noting the revision letter in the upper right hand corner of the Start screen. It should match the revision letter noted when the updater zip file was extracted.
DXN Portable Ultrasonic Measurement System QUICK BOOT It is highly recommended to configure the DXN to use the Quick Boot process as described in the following. To enable Quick Boot from the main screen select Update (System ► Update) and then press the Set Up Quick Boot button. Display Misc Site Meter Power Disk Log PC I/O Storage Adv ENet Time Cal Update System Comm Quit Meter to Manage / Update GUI -> Rev A = V 001.1 20111116.0 DSP -> Rev A = V 001.1 20111116.
Badger Meter Warranty DXN Updater PRODUCTS COVERED The Badger Meter warranty shall apply to the Dynasonics Flow Meter (“Product”). MATERIALS AND WORKMANSHIP Badger Meter warrants the Product to be free from defects in materials and workmanship for a period of 12 months from the original purchase date. PRODUCT RETURNS Product failures must be proven and verified to the satisfaction of Badger Meter.
Dynasonics is a registered trademark of Badger Meter, Inc. Other trademarks appearing in this document are the property of their respective entities. Due to continuous research, product improvements and enhancements, Badger Meter reserves the right to change product or system specifications without notice, except to the extent an outstanding contractual obligation exists. © 2013 Badger Meter, Inc. All rights reserved. www.badgermeter.